Cargando…

Invasive electrophysiological testing to predict and guide permanent pacemaker implantation after transcatheter aortic valve implantation: A meta-analysis

BACKGROUND: Atrioventricular conduction abnormalities after transcatheter aortic valve implantation (TAVI) are common. The value of electrophysiological study (EPS) for risk stratification of high-grade atrioventricular block (HG-AVB) and guidance of permanent pacemaker (PPM) implantation is poorly...

Descripción completa

Detalles Bibliográficos
Autores principales: Siontis, Konstantinos C., Kara Balla, Abdalla, Cha, Yong-Mei, Pilgrim, Thomas, Sweda, Romy, Roten, Laurent, Reichlin, Tobias, Friedman, Paul A., Windecker, Stephan, Siontis, George C.M.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9877393/
https://www.ncbi.nlm.nih.gov/pubmed/36713040
http://dx.doi.org/10.1016/j.hroo.2022.10.007
Descripción
Sumario:BACKGROUND: Atrioventricular conduction abnormalities after transcatheter aortic valve implantation (TAVI) are common. The value of electrophysiological study (EPS) for risk stratification of high-grade atrioventricular block (HG-AVB) and guidance of permanent pacemaker (PPM) implantation is poorly defined. OBJECTIVE: The purpose of this study was to identify EPS parameters associated with HG-AVB and determine the value of EPS-guided PPM implantation after TAVI. METHODS: We performed a systematic review and meta-analysis of studies investigating the value of EPS parameters for risk stratification of TAVI-related HG-AVB and for guidance of PPM implantation among patients with equivocal PPM indications after TAVI. RESULTS: Eighteen studies (1230 patients) were eligible. In 7 studies, EPS was performed only after TAVI, whereas in 11 studies EPS was performed both before and after TAVI. Overall PPM implantation rate for HG-AVB was 16%. AV conduction intervals prolonged after TAVI, with the AH and HV intervals showing the largest magnitude of changes. Pre-TAVI HV >70 ms and the absolute value of the post-TAVI HV interval were associated with subsequent HG-AVB and PPM implantation with odds ratios of 2.53 (95% confidence interval [CI] 1.11–5.81; P = .04) and 1.10 (95% CI 1.03–1.17; P = .02; per 1-ms increase), respectively. In 10 studies, PPM was also implanted due to abnormal EPS findings in patients with equivocal PPM indications post-TAVI (typically new left bundle branch block or transient HG-AVB). Among them, the rate of long-term PPM dependency was 57%. CONCLUSION: Selective EPS testing may assist in the risk stratification of post-TAVI HG-AVB and in the guidance of PPM implantation, especially in patients with equivocal PPM indications post-TAVI.