Cargando…

Invasive electrophysiological testing to predict and guide permanent pacemaker implantation after transcatheter aortic valve implantation: A meta-analysis

BACKGROUND: Atrioventricular conduction abnormalities after transcatheter aortic valve implantation (TAVI) are common. The value of electrophysiological study (EPS) for risk stratification of high-grade atrioventricular block (HG-AVB) and guidance of permanent pacemaker (PPM) implantation is poorly...

Descripción completa

Detalles Bibliográficos
Autores principales: Siontis, Konstantinos C., Kara Balla, Abdalla, Cha, Yong-Mei, Pilgrim, Thomas, Sweda, Romy, Roten, Laurent, Reichlin, Tobias, Friedman, Paul A., Windecker, Stephan, Siontis, George C.M.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9877393/
https://www.ncbi.nlm.nih.gov/pubmed/36713040
http://dx.doi.org/10.1016/j.hroo.2022.10.007
_version_ 1784878354438029312
author Siontis, Konstantinos C.
Kara Balla, Abdalla
Cha, Yong-Mei
Pilgrim, Thomas
Sweda, Romy
Roten, Laurent
Reichlin, Tobias
Friedman, Paul A.
Windecker, Stephan
Siontis, George C.M.
author_facet Siontis, Konstantinos C.
Kara Balla, Abdalla
Cha, Yong-Mei
Pilgrim, Thomas
Sweda, Romy
Roten, Laurent
Reichlin, Tobias
Friedman, Paul A.
Windecker, Stephan
Siontis, George C.M.
author_sort Siontis, Konstantinos C.
collection PubMed
description BACKGROUND: Atrioventricular conduction abnormalities after transcatheter aortic valve implantation (TAVI) are common. The value of electrophysiological study (EPS) for risk stratification of high-grade atrioventricular block (HG-AVB) and guidance of permanent pacemaker (PPM) implantation is poorly defined. OBJECTIVE: The purpose of this study was to identify EPS parameters associated with HG-AVB and determine the value of EPS-guided PPM implantation after TAVI. METHODS: We performed a systematic review and meta-analysis of studies investigating the value of EPS parameters for risk stratification of TAVI-related HG-AVB and for guidance of PPM implantation among patients with equivocal PPM indications after TAVI. RESULTS: Eighteen studies (1230 patients) were eligible. In 7 studies, EPS was performed only after TAVI, whereas in 11 studies EPS was performed both before and after TAVI. Overall PPM implantation rate for HG-AVB was 16%. AV conduction intervals prolonged after TAVI, with the AH and HV intervals showing the largest magnitude of changes. Pre-TAVI HV >70 ms and the absolute value of the post-TAVI HV interval were associated with subsequent HG-AVB and PPM implantation with odds ratios of 2.53 (95% confidence interval [CI] 1.11–5.81; P = .04) and 1.10 (95% CI 1.03–1.17; P = .02; per 1-ms increase), respectively. In 10 studies, PPM was also implanted due to abnormal EPS findings in patients with equivocal PPM indications post-TAVI (typically new left bundle branch block or transient HG-AVB). Among them, the rate of long-term PPM dependency was 57%. CONCLUSION: Selective EPS testing may assist in the risk stratification of post-TAVI HG-AVB and in the guidance of PPM implantation, especially in patients with equivocal PPM indications post-TAVI.
format Online
Article
Text
id pubmed-9877393
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-98773932023-01-27 Invasive electrophysiological testing to predict and guide permanent pacemaker implantation after transcatheter aortic valve implantation: A meta-analysis Siontis, Konstantinos C. Kara Balla, Abdalla Cha, Yong-Mei Pilgrim, Thomas Sweda, Romy Roten, Laurent Reichlin, Tobias Friedman, Paul A. Windecker, Stephan Siontis, George C.M. Heart Rhythm O2 Clinical BACKGROUND: Atrioventricular conduction abnormalities after transcatheter aortic valve implantation (TAVI) are common. The value of electrophysiological study (EPS) for risk stratification of high-grade atrioventricular block (HG-AVB) and guidance of permanent pacemaker (PPM) implantation is poorly defined. OBJECTIVE: The purpose of this study was to identify EPS parameters associated with HG-AVB and determine the value of EPS-guided PPM implantation after TAVI. METHODS: We performed a systematic review and meta-analysis of studies investigating the value of EPS parameters for risk stratification of TAVI-related HG-AVB and for guidance of PPM implantation among patients with equivocal PPM indications after TAVI. RESULTS: Eighteen studies (1230 patients) were eligible. In 7 studies, EPS was performed only after TAVI, whereas in 11 studies EPS was performed both before and after TAVI. Overall PPM implantation rate for HG-AVB was 16%. AV conduction intervals prolonged after TAVI, with the AH and HV intervals showing the largest magnitude of changes. Pre-TAVI HV >70 ms and the absolute value of the post-TAVI HV interval were associated with subsequent HG-AVB and PPM implantation with odds ratios of 2.53 (95% confidence interval [CI] 1.11–5.81; P = .04) and 1.10 (95% CI 1.03–1.17; P = .02; per 1-ms increase), respectively. In 10 studies, PPM was also implanted due to abnormal EPS findings in patients with equivocal PPM indications post-TAVI (typically new left bundle branch block or transient HG-AVB). Among them, the rate of long-term PPM dependency was 57%. CONCLUSION: Selective EPS testing may assist in the risk stratification of post-TAVI HG-AVB and in the guidance of PPM implantation, especially in patients with equivocal PPM indications post-TAVI. Elsevier 2022-10-22 /pmc/articles/PMC9877393/ /pubmed/36713040 http://dx.doi.org/10.1016/j.hroo.2022.10.007 Text en © 2022 Heart Rhythm Society. Published by Elsevier Inc. https://creativecommons.org/licenses/by/4.0/This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Clinical
Siontis, Konstantinos C.
Kara Balla, Abdalla
Cha, Yong-Mei
Pilgrim, Thomas
Sweda, Romy
Roten, Laurent
Reichlin, Tobias
Friedman, Paul A.
Windecker, Stephan
Siontis, George C.M.
Invasive electrophysiological testing to predict and guide permanent pacemaker implantation after transcatheter aortic valve implantation: A meta-analysis
title Invasive electrophysiological testing to predict and guide permanent pacemaker implantation after transcatheter aortic valve implantation: A meta-analysis
title_full Invasive electrophysiological testing to predict and guide permanent pacemaker implantation after transcatheter aortic valve implantation: A meta-analysis
title_fullStr Invasive electrophysiological testing to predict and guide permanent pacemaker implantation after transcatheter aortic valve implantation: A meta-analysis
title_full_unstemmed Invasive electrophysiological testing to predict and guide permanent pacemaker implantation after transcatheter aortic valve implantation: A meta-analysis
title_short Invasive electrophysiological testing to predict and guide permanent pacemaker implantation after transcatheter aortic valve implantation: A meta-analysis
title_sort invasive electrophysiological testing to predict and guide permanent pacemaker implantation after transcatheter aortic valve implantation: a meta-analysis
topic Clinical
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9877393/
https://www.ncbi.nlm.nih.gov/pubmed/36713040
http://dx.doi.org/10.1016/j.hroo.2022.10.007
work_keys_str_mv AT siontiskonstantinosc invasiveelectrophysiologicaltestingtopredictandguidepermanentpacemakerimplantationaftertranscatheteraorticvalveimplantationametaanalysis
AT karaballaabdalla invasiveelectrophysiologicaltestingtopredictandguidepermanentpacemakerimplantationaftertranscatheteraorticvalveimplantationametaanalysis
AT chayongmei invasiveelectrophysiologicaltestingtopredictandguidepermanentpacemakerimplantationaftertranscatheteraorticvalveimplantationametaanalysis
AT pilgrimthomas invasiveelectrophysiologicaltestingtopredictandguidepermanentpacemakerimplantationaftertranscatheteraorticvalveimplantationametaanalysis
AT swedaromy invasiveelectrophysiologicaltestingtopredictandguidepermanentpacemakerimplantationaftertranscatheteraorticvalveimplantationametaanalysis
AT rotenlaurent invasiveelectrophysiologicaltestingtopredictandguidepermanentpacemakerimplantationaftertranscatheteraorticvalveimplantationametaanalysis
AT reichlintobias invasiveelectrophysiologicaltestingtopredictandguidepermanentpacemakerimplantationaftertranscatheteraorticvalveimplantationametaanalysis
AT friedmanpaula invasiveelectrophysiologicaltestingtopredictandguidepermanentpacemakerimplantationaftertranscatheteraorticvalveimplantationametaanalysis
AT windeckerstephan invasiveelectrophysiologicaltestingtopredictandguidepermanentpacemakerimplantationaftertranscatheteraorticvalveimplantationametaanalysis
AT siontisgeorgecm invasiveelectrophysiologicaltestingtopredictandguidepermanentpacemakerimplantationaftertranscatheteraorticvalveimplantationametaanalysis