Invasive electrophysiological testing to predict and guide permanent pacemaker implantation after transcatheter aortic valve implantation: A meta-analysis
BACKGROUND: Atrioventricular conduction abnormalities after transcatheter aortic valve implantation (TAVI) are common. The value of electrophysiological study (EPS) for risk stratification of high-grade atrioventricular block (HG-AVB) and guidance of permanent pacemaker (PPM) implantation is poorly...
Autores principales: | , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9877393/ https://www.ncbi.nlm.nih.gov/pubmed/36713040 http://dx.doi.org/10.1016/j.hroo.2022.10.007 |
_version_ | 1784878354438029312 |
---|---|
author | Siontis, Konstantinos C. Kara Balla, Abdalla Cha, Yong-Mei Pilgrim, Thomas Sweda, Romy Roten, Laurent Reichlin, Tobias Friedman, Paul A. Windecker, Stephan Siontis, George C.M. |
author_facet | Siontis, Konstantinos C. Kara Balla, Abdalla Cha, Yong-Mei Pilgrim, Thomas Sweda, Romy Roten, Laurent Reichlin, Tobias Friedman, Paul A. Windecker, Stephan Siontis, George C.M. |
author_sort | Siontis, Konstantinos C. |
collection | PubMed |
description | BACKGROUND: Atrioventricular conduction abnormalities after transcatheter aortic valve implantation (TAVI) are common. The value of electrophysiological study (EPS) for risk stratification of high-grade atrioventricular block (HG-AVB) and guidance of permanent pacemaker (PPM) implantation is poorly defined. OBJECTIVE: The purpose of this study was to identify EPS parameters associated with HG-AVB and determine the value of EPS-guided PPM implantation after TAVI. METHODS: We performed a systematic review and meta-analysis of studies investigating the value of EPS parameters for risk stratification of TAVI-related HG-AVB and for guidance of PPM implantation among patients with equivocal PPM indications after TAVI. RESULTS: Eighteen studies (1230 patients) were eligible. In 7 studies, EPS was performed only after TAVI, whereas in 11 studies EPS was performed both before and after TAVI. Overall PPM implantation rate for HG-AVB was 16%. AV conduction intervals prolonged after TAVI, with the AH and HV intervals showing the largest magnitude of changes. Pre-TAVI HV >70 ms and the absolute value of the post-TAVI HV interval were associated with subsequent HG-AVB and PPM implantation with odds ratios of 2.53 (95% confidence interval [CI] 1.11–5.81; P = .04) and 1.10 (95% CI 1.03–1.17; P = .02; per 1-ms increase), respectively. In 10 studies, PPM was also implanted due to abnormal EPS findings in patients with equivocal PPM indications post-TAVI (typically new left bundle branch block or transient HG-AVB). Among them, the rate of long-term PPM dependency was 57%. CONCLUSION: Selective EPS testing may assist in the risk stratification of post-TAVI HG-AVB and in the guidance of PPM implantation, especially in patients with equivocal PPM indications post-TAVI. |
format | Online Article Text |
id | pubmed-9877393 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Elsevier |
record_format | MEDLINE/PubMed |
spelling | pubmed-98773932023-01-27 Invasive electrophysiological testing to predict and guide permanent pacemaker implantation after transcatheter aortic valve implantation: A meta-analysis Siontis, Konstantinos C. Kara Balla, Abdalla Cha, Yong-Mei Pilgrim, Thomas Sweda, Romy Roten, Laurent Reichlin, Tobias Friedman, Paul A. Windecker, Stephan Siontis, George C.M. Heart Rhythm O2 Clinical BACKGROUND: Atrioventricular conduction abnormalities after transcatheter aortic valve implantation (TAVI) are common. The value of electrophysiological study (EPS) for risk stratification of high-grade atrioventricular block (HG-AVB) and guidance of permanent pacemaker (PPM) implantation is poorly defined. OBJECTIVE: The purpose of this study was to identify EPS parameters associated with HG-AVB and determine the value of EPS-guided PPM implantation after TAVI. METHODS: We performed a systematic review and meta-analysis of studies investigating the value of EPS parameters for risk stratification of TAVI-related HG-AVB and for guidance of PPM implantation among patients with equivocal PPM indications after TAVI. RESULTS: Eighteen studies (1230 patients) were eligible. In 7 studies, EPS was performed only after TAVI, whereas in 11 studies EPS was performed both before and after TAVI. Overall PPM implantation rate for HG-AVB was 16%. AV conduction intervals prolonged after TAVI, with the AH and HV intervals showing the largest magnitude of changes. Pre-TAVI HV >70 ms and the absolute value of the post-TAVI HV interval were associated with subsequent HG-AVB and PPM implantation with odds ratios of 2.53 (95% confidence interval [CI] 1.11–5.81; P = .04) and 1.10 (95% CI 1.03–1.17; P = .02; per 1-ms increase), respectively. In 10 studies, PPM was also implanted due to abnormal EPS findings in patients with equivocal PPM indications post-TAVI (typically new left bundle branch block or transient HG-AVB). Among them, the rate of long-term PPM dependency was 57%. CONCLUSION: Selective EPS testing may assist in the risk stratification of post-TAVI HG-AVB and in the guidance of PPM implantation, especially in patients with equivocal PPM indications post-TAVI. Elsevier 2022-10-22 /pmc/articles/PMC9877393/ /pubmed/36713040 http://dx.doi.org/10.1016/j.hroo.2022.10.007 Text en © 2022 Heart Rhythm Society. Published by Elsevier Inc. https://creativecommons.org/licenses/by/4.0/This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Clinical Siontis, Konstantinos C. Kara Balla, Abdalla Cha, Yong-Mei Pilgrim, Thomas Sweda, Romy Roten, Laurent Reichlin, Tobias Friedman, Paul A. Windecker, Stephan Siontis, George C.M. Invasive electrophysiological testing to predict and guide permanent pacemaker implantation after transcatheter aortic valve implantation: A meta-analysis |
title | Invasive electrophysiological testing to predict and guide permanent pacemaker implantation after transcatheter aortic valve implantation: A meta-analysis |
title_full | Invasive electrophysiological testing to predict and guide permanent pacemaker implantation after transcatheter aortic valve implantation: A meta-analysis |
title_fullStr | Invasive electrophysiological testing to predict and guide permanent pacemaker implantation after transcatheter aortic valve implantation: A meta-analysis |
title_full_unstemmed | Invasive electrophysiological testing to predict and guide permanent pacemaker implantation after transcatheter aortic valve implantation: A meta-analysis |
title_short | Invasive electrophysiological testing to predict and guide permanent pacemaker implantation after transcatheter aortic valve implantation: A meta-analysis |
title_sort | invasive electrophysiological testing to predict and guide permanent pacemaker implantation after transcatheter aortic valve implantation: a meta-analysis |
topic | Clinical |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9877393/ https://www.ncbi.nlm.nih.gov/pubmed/36713040 http://dx.doi.org/10.1016/j.hroo.2022.10.007 |
work_keys_str_mv | AT siontiskonstantinosc invasiveelectrophysiologicaltestingtopredictandguidepermanentpacemakerimplantationaftertranscatheteraorticvalveimplantationametaanalysis AT karaballaabdalla invasiveelectrophysiologicaltestingtopredictandguidepermanentpacemakerimplantationaftertranscatheteraorticvalveimplantationametaanalysis AT chayongmei invasiveelectrophysiologicaltestingtopredictandguidepermanentpacemakerimplantationaftertranscatheteraorticvalveimplantationametaanalysis AT pilgrimthomas invasiveelectrophysiologicaltestingtopredictandguidepermanentpacemakerimplantationaftertranscatheteraorticvalveimplantationametaanalysis AT swedaromy invasiveelectrophysiologicaltestingtopredictandguidepermanentpacemakerimplantationaftertranscatheteraorticvalveimplantationametaanalysis AT rotenlaurent invasiveelectrophysiologicaltestingtopredictandguidepermanentpacemakerimplantationaftertranscatheteraorticvalveimplantationametaanalysis AT reichlintobias invasiveelectrophysiologicaltestingtopredictandguidepermanentpacemakerimplantationaftertranscatheteraorticvalveimplantationametaanalysis AT friedmanpaula invasiveelectrophysiologicaltestingtopredictandguidepermanentpacemakerimplantationaftertranscatheteraorticvalveimplantationametaanalysis AT windeckerstephan invasiveelectrophysiologicaltestingtopredictandguidepermanentpacemakerimplantationaftertranscatheteraorticvalveimplantationametaanalysis AT siontisgeorgecm invasiveelectrophysiologicaltestingtopredictandguidepermanentpacemakerimplantationaftertranscatheteraorticvalveimplantationametaanalysis |