Evaluating an advanced double intravenous vasopressor automated system to treat hypotension during spinal anesthesia for cesarean delivery: a randomized controlled trial

BACKGROUND: The optimal treatment of hypotension during spinal anaesthesia is uncertain. A novel double intravenous vasopressor automated (DIVA) system reduces hypotension compared to standard care, and was subsequently modified to an advanced-DIVA (ADIVA) system. The primary objective was to compar...

Descripción completa

Detalles Bibliográficos
Autores principales: Tan, Hon Sen, Nagarajan, Singaraselvan, Chan, Jason Ju In, Tan, Chin Wen, Sultana, Rehena, Sia, Alex Tiong Heng, Sng, Ban Leong
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9878794/
https://www.ncbi.nlm.nih.gov/pubmed/36703120
http://dx.doi.org/10.1186/s12871-023-01992-7
_version_ 1784878565250039808
author Tan, Hon Sen
Nagarajan, Singaraselvan
Chan, Jason Ju In
Tan, Chin Wen
Sultana, Rehena
Sia, Alex Tiong Heng
Sng, Ban Leong
author_facet Tan, Hon Sen
Nagarajan, Singaraselvan
Chan, Jason Ju In
Tan, Chin Wen
Sultana, Rehena
Sia, Alex Tiong Heng
Sng, Ban Leong
author_sort Tan, Hon Sen
collection PubMed
description BACKGROUND: The optimal treatment of hypotension during spinal anaesthesia is uncertain. A novel double intravenous vasopressor automated (DIVA) system reduces hypotension compared to standard care, and was subsequently modified to an advanced-DIVA (ADIVA) system. The primary objective was to compare ADIVA versus DIVA on incidence of hypotension (systolic BP (SBP) < 80% baseline). METHODS: We conducted a randomized-controlled trial in women undergoing elective cesarean delivery under spinal anesthesia. SBP and heart rate were measured continuously using a Nexfin monitor. ADIVA delivered 25 μg phenylephrine (heart rate > 60 beats.min(−1)) or 2 mg ephedrine (heart rate < 60 beats.min(−1)) at SBP 90 to 110% of baseline, 50 μg phenylephrine or 4 mg ephedrine at SBP 80 to 90%, and 75 μg phenylephrine or 6 mg ephedrine at SBP < 80%. ADIVA calculated the trend of SBP; vasopressors were administered rapidly if SBP trended downward, or 30 s if SBP trended upward. In contrast, DIVA delivered 25 μg phenylephrine or 2 mg ephedrine at SBP 90 to 100% of baseline, and 50 μg phenylephrine or 4 mg ephedrine at SBP < 90%. Boluses were followed by a 10-s lockout. Other outcomes included hypertension (SBP > 120% baseline), vasopressor consumption, clinical outcomes, and performance measures from spinal anesthesia to fetal delivery. RESULTS: We analyzed 94 parturients (ADIVA: n = 46, DIVA: n = 48), with no difference in the incidence of hypotension between ADIVA (78.3%) and DIVA (83.3%, p = 0.677). ADIVA had significantly higher proportion of hypotensive SBP readings, lower phenylephrine consumption and higher umbilical arterial pH. There was no difference in hypertension, bradycardia, ephedrine consumption, intravenous fluid volume, nausea/vomiting, Apgar scores, and umbilical venous pH or lactate. ADIVA maintained SBP higher above baseline with greater fluctuation than DIVA. CONCLUSION: ADIVA was associated with a greater proportion of hypotensive SBP readings, reduced phenylephrine consumption, and increased umbilical arterial pH than DIVA. Further research is needed to determine the optimal method of vasopressor delivery in parturients undergoing cesarean delivery. TRIAL REGISTRATION: This study was registered on Clinicaltrials.gov registry (NCT03620942) on 08/08/2018.
format Online
Article
Text
id pubmed-9878794
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-98787942023-01-27 Evaluating an advanced double intravenous vasopressor automated system to treat hypotension during spinal anesthesia for cesarean delivery: a randomized controlled trial Tan, Hon Sen Nagarajan, Singaraselvan Chan, Jason Ju In Tan, Chin Wen Sultana, Rehena Sia, Alex Tiong Heng Sng, Ban Leong BMC Anesthesiol Research BACKGROUND: The optimal treatment of hypotension during spinal anaesthesia is uncertain. A novel double intravenous vasopressor automated (DIVA) system reduces hypotension compared to standard care, and was subsequently modified to an advanced-DIVA (ADIVA) system. The primary objective was to compare ADIVA versus DIVA on incidence of hypotension (systolic BP (SBP) < 80% baseline). METHODS: We conducted a randomized-controlled trial in women undergoing elective cesarean delivery under spinal anesthesia. SBP and heart rate were measured continuously using a Nexfin monitor. ADIVA delivered 25 μg phenylephrine (heart rate > 60 beats.min(−1)) or 2 mg ephedrine (heart rate < 60 beats.min(−1)) at SBP 90 to 110% of baseline, 50 μg phenylephrine or 4 mg ephedrine at SBP 80 to 90%, and 75 μg phenylephrine or 6 mg ephedrine at SBP < 80%. ADIVA calculated the trend of SBP; vasopressors were administered rapidly if SBP trended downward, or 30 s if SBP trended upward. In contrast, DIVA delivered 25 μg phenylephrine or 2 mg ephedrine at SBP 90 to 100% of baseline, and 50 μg phenylephrine or 4 mg ephedrine at SBP < 90%. Boluses were followed by a 10-s lockout. Other outcomes included hypertension (SBP > 120% baseline), vasopressor consumption, clinical outcomes, and performance measures from spinal anesthesia to fetal delivery. RESULTS: We analyzed 94 parturients (ADIVA: n = 46, DIVA: n = 48), with no difference in the incidence of hypotension between ADIVA (78.3%) and DIVA (83.3%, p = 0.677). ADIVA had significantly higher proportion of hypotensive SBP readings, lower phenylephrine consumption and higher umbilical arterial pH. There was no difference in hypertension, bradycardia, ephedrine consumption, intravenous fluid volume, nausea/vomiting, Apgar scores, and umbilical venous pH or lactate. ADIVA maintained SBP higher above baseline with greater fluctuation than DIVA. CONCLUSION: ADIVA was associated with a greater proportion of hypotensive SBP readings, reduced phenylephrine consumption, and increased umbilical arterial pH than DIVA. Further research is needed to determine the optimal method of vasopressor delivery in parturients undergoing cesarean delivery. TRIAL REGISTRATION: This study was registered on Clinicaltrials.gov registry (NCT03620942) on 08/08/2018. BioMed Central 2023-01-26 /pmc/articles/PMC9878794/ /pubmed/36703120 http://dx.doi.org/10.1186/s12871-023-01992-7 Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Research
Tan, Hon Sen
Nagarajan, Singaraselvan
Chan, Jason Ju In
Tan, Chin Wen
Sultana, Rehena
Sia, Alex Tiong Heng
Sng, Ban Leong
Evaluating an advanced double intravenous vasopressor automated system to treat hypotension during spinal anesthesia for cesarean delivery: a randomized controlled trial
title Evaluating an advanced double intravenous vasopressor automated system to treat hypotension during spinal anesthesia for cesarean delivery: a randomized controlled trial
title_full Evaluating an advanced double intravenous vasopressor automated system to treat hypotension during spinal anesthesia for cesarean delivery: a randomized controlled trial
title_fullStr Evaluating an advanced double intravenous vasopressor automated system to treat hypotension during spinal anesthesia for cesarean delivery: a randomized controlled trial
title_full_unstemmed Evaluating an advanced double intravenous vasopressor automated system to treat hypotension during spinal anesthesia for cesarean delivery: a randomized controlled trial
title_short Evaluating an advanced double intravenous vasopressor automated system to treat hypotension during spinal anesthesia for cesarean delivery: a randomized controlled trial
title_sort evaluating an advanced double intravenous vasopressor automated system to treat hypotension during spinal anesthesia for cesarean delivery: a randomized controlled trial
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9878794/
https://www.ncbi.nlm.nih.gov/pubmed/36703120
http://dx.doi.org/10.1186/s12871-023-01992-7
work_keys_str_mv AT tanhonsen evaluatinganadvanceddoubleintravenousvasopressorautomatedsystemtotreathypotensionduringspinalanesthesiaforcesareandeliveryarandomizedcontrolledtrial
AT nagarajansingaraselvan evaluatinganadvanceddoubleintravenousvasopressorautomatedsystemtotreathypotensionduringspinalanesthesiaforcesareandeliveryarandomizedcontrolledtrial
AT chanjasonjuin evaluatinganadvanceddoubleintravenousvasopressorautomatedsystemtotreathypotensionduringspinalanesthesiaforcesareandeliveryarandomizedcontrolledtrial
AT tanchinwen evaluatinganadvanceddoubleintravenousvasopressorautomatedsystemtotreathypotensionduringspinalanesthesiaforcesareandeliveryarandomizedcontrolledtrial
AT sultanarehena evaluatinganadvanceddoubleintravenousvasopressorautomatedsystemtotreathypotensionduringspinalanesthesiaforcesareandeliveryarandomizedcontrolledtrial
AT siaalextiongheng evaluatinganadvanceddoubleintravenousvasopressorautomatedsystemtotreathypotensionduringspinalanesthesiaforcesareandeliveryarandomizedcontrolledtrial
AT sngbanleong evaluatinganadvanceddoubleintravenousvasopressorautomatedsystemtotreathypotensionduringspinalanesthesiaforcesareandeliveryarandomizedcontrolledtrial