Cargando…

Differential value of diffusion kurtosis imaging and intravoxel incoherent motion in benign and malignant solitary pulmonary lesions

OBJECTIVE: To investigate the diagnostic value of diffusion kurtosis imaging (DKI) and intravoxel incoherent motion (IVIM) whole-lesion histogram parameters in differentiating benign and malignant solitary pulmonary lesions (SPLs). MATERIALS AND METHODS: Patients with SPLs detected by chest CT exami...

Descripción completa

Detalles Bibliográficos
Autores principales: Xiang, Lu, Yang, Hong, Qin, Yu, Wen, Yun, Liu, Xue, Zeng, Wen-Bing
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9878824/
https://www.ncbi.nlm.nih.gov/pubmed/36713551
http://dx.doi.org/10.3389/fonc.2022.1075072
_version_ 1784878570213998592
author Xiang, Lu
Yang, Hong
Qin, Yu
Wen, Yun
Liu, Xue
Zeng, Wen-Bing
author_facet Xiang, Lu
Yang, Hong
Qin, Yu
Wen, Yun
Liu, Xue
Zeng, Wen-Bing
author_sort Xiang, Lu
collection PubMed
description OBJECTIVE: To investigate the diagnostic value of diffusion kurtosis imaging (DKI) and intravoxel incoherent motion (IVIM) whole-lesion histogram parameters in differentiating benign and malignant solitary pulmonary lesions (SPLs). MATERIALS AND METHODS: Patients with SPLs detected by chest CT examination and with further routine MRI, DKI and IVIM-DWI functional sequence scanning data were recruited. According to the pathological results, SPLs were divided into a benign group and a malignant group. Independent samples t tests (normal distribution) or Mann‒Whitney U tests (nonnormal distribution) were used to compare the differences in DKI (Dk, K), IVIM (D, D*, f) and ADC whole-lesion histogram parameters between the benign and malignant SPL groups. The receiver operating characteristic (ROC) curve was used to evaluate the diagnostic efficiency of the histogram parameters and determine the optimal threshold. The area under the curve (AUC) of each histogram parameter was compared by the DeLong method. Spearman rank correlation was used to analyze the correlation between histogram parameters and malignant SPLs. RESULTS: Most of the histogram parameters for diffusion-related values (Dk, D, ADC) of malignant SPLs were significantly lower than those of benign SPLs, while most of the histogram parameters for the K value of malignant SPLs were significantly higher than those of benign SPLs. DKI (Dk, K), IVIM (D) and ADC were effective in differentiating benign and malignant SPLs and combined with multiple parameters of the whole-lesion histogram for the D value, had the highest diagnostic efficiency, with an AUC of 0.967, a sensitivity of 90.00% and a specificity of 94.03%. Most of the histogram parameters for the Dk, D and ADC values were negatively correlated with malignant SPLs, while most of the histogram parameters for the K value were positively correlated with malignant SPLs. CONCLUSIONS: DKI (Dk, K) and IVIM (D) whole-lesion histogram parameters can noninvasively distinguish benign and malignant SPLs, and the diagnostic performance is better than that of DWI. Moreover, they can provide additional information on SPL microstructure, which has important significance for guiding clinical individualized precision diagnosis and treatment and has potential clinical application value.
format Online
Article
Text
id pubmed-9878824
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-98788242023-01-27 Differential value of diffusion kurtosis imaging and intravoxel incoherent motion in benign and malignant solitary pulmonary lesions Xiang, Lu Yang, Hong Qin, Yu Wen, Yun Liu, Xue Zeng, Wen-Bing Front Oncol Oncology OBJECTIVE: To investigate the diagnostic value of diffusion kurtosis imaging (DKI) and intravoxel incoherent motion (IVIM) whole-lesion histogram parameters in differentiating benign and malignant solitary pulmonary lesions (SPLs). MATERIALS AND METHODS: Patients with SPLs detected by chest CT examination and with further routine MRI, DKI and IVIM-DWI functional sequence scanning data were recruited. According to the pathological results, SPLs were divided into a benign group and a malignant group. Independent samples t tests (normal distribution) or Mann‒Whitney U tests (nonnormal distribution) were used to compare the differences in DKI (Dk, K), IVIM (D, D*, f) and ADC whole-lesion histogram parameters between the benign and malignant SPL groups. The receiver operating characteristic (ROC) curve was used to evaluate the diagnostic efficiency of the histogram parameters and determine the optimal threshold. The area under the curve (AUC) of each histogram parameter was compared by the DeLong method. Spearman rank correlation was used to analyze the correlation between histogram parameters and malignant SPLs. RESULTS: Most of the histogram parameters for diffusion-related values (Dk, D, ADC) of malignant SPLs were significantly lower than those of benign SPLs, while most of the histogram parameters for the K value of malignant SPLs were significantly higher than those of benign SPLs. DKI (Dk, K), IVIM (D) and ADC were effective in differentiating benign and malignant SPLs and combined with multiple parameters of the whole-lesion histogram for the D value, had the highest diagnostic efficiency, with an AUC of 0.967, a sensitivity of 90.00% and a specificity of 94.03%. Most of the histogram parameters for the Dk, D and ADC values were negatively correlated with malignant SPLs, while most of the histogram parameters for the K value were positively correlated with malignant SPLs. CONCLUSIONS: DKI (Dk, K) and IVIM (D) whole-lesion histogram parameters can noninvasively distinguish benign and malignant SPLs, and the diagnostic performance is better than that of DWI. Moreover, they can provide additional information on SPL microstructure, which has important significance for guiding clinical individualized precision diagnosis and treatment and has potential clinical application value. Frontiers Media S.A. 2023-01-12 /pmc/articles/PMC9878824/ /pubmed/36713551 http://dx.doi.org/10.3389/fonc.2022.1075072 Text en Copyright © 2023 Xiang, Yang, Qin, Wen, Liu and Zeng https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Oncology
Xiang, Lu
Yang, Hong
Qin, Yu
Wen, Yun
Liu, Xue
Zeng, Wen-Bing
Differential value of diffusion kurtosis imaging and intravoxel incoherent motion in benign and malignant solitary pulmonary lesions
title Differential value of diffusion kurtosis imaging and intravoxel incoherent motion in benign and malignant solitary pulmonary lesions
title_full Differential value of diffusion kurtosis imaging and intravoxel incoherent motion in benign and malignant solitary pulmonary lesions
title_fullStr Differential value of diffusion kurtosis imaging and intravoxel incoherent motion in benign and malignant solitary pulmonary lesions
title_full_unstemmed Differential value of diffusion kurtosis imaging and intravoxel incoherent motion in benign and malignant solitary pulmonary lesions
title_short Differential value of diffusion kurtosis imaging and intravoxel incoherent motion in benign and malignant solitary pulmonary lesions
title_sort differential value of diffusion kurtosis imaging and intravoxel incoherent motion in benign and malignant solitary pulmonary lesions
topic Oncology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9878824/
https://www.ncbi.nlm.nih.gov/pubmed/36713551
http://dx.doi.org/10.3389/fonc.2022.1075072
work_keys_str_mv AT xianglu differentialvalueofdiffusionkurtosisimagingandintravoxelincoherentmotioninbenignandmalignantsolitarypulmonarylesions
AT yanghong differentialvalueofdiffusionkurtosisimagingandintravoxelincoherentmotioninbenignandmalignantsolitarypulmonarylesions
AT qinyu differentialvalueofdiffusionkurtosisimagingandintravoxelincoherentmotioninbenignandmalignantsolitarypulmonarylesions
AT wenyun differentialvalueofdiffusionkurtosisimagingandintravoxelincoherentmotioninbenignandmalignantsolitarypulmonarylesions
AT liuxue differentialvalueofdiffusionkurtosisimagingandintravoxelincoherentmotioninbenignandmalignantsolitarypulmonarylesions
AT zengwenbing differentialvalueofdiffusionkurtosisimagingandintravoxelincoherentmotioninbenignandmalignantsolitarypulmonarylesions