Cargando…

Ultrasensitive electrochemical biosensors based on zinc sulfide/graphene hybrid for rapid detection of SARS-CoV-2

The coronavirus disease 2019 (COVID-19) is a highly contagious and fatal disease caused by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). In general, the diagnostic tests for COVID-19 are based on the detection of nucleic acid, antibodies, and protein. Among different analytes, the go...

Descripción completa

Detalles Bibliográficos
Autores principales: Sarwar, Shatila, Lin, Mao-Chia, Amezaga, Carolina, Wei, Zhen, Iyayi, Etinosa, Polk, Haseena, Wang, Ruigang, Wang, Honghe, Zhang, Xinyu
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer International Publishing 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9879254/
https://www.ncbi.nlm.nih.gov/pubmed/36718472
http://dx.doi.org/10.1007/s42114-023-00630-7
_version_ 1784878652761047040
author Sarwar, Shatila
Lin, Mao-Chia
Amezaga, Carolina
Wei, Zhen
Iyayi, Etinosa
Polk, Haseena
Wang, Ruigang
Wang, Honghe
Zhang, Xinyu
author_facet Sarwar, Shatila
Lin, Mao-Chia
Amezaga, Carolina
Wei, Zhen
Iyayi, Etinosa
Polk, Haseena
Wang, Ruigang
Wang, Honghe
Zhang, Xinyu
author_sort Sarwar, Shatila
collection PubMed
description The coronavirus disease 2019 (COVID-19) is a highly contagious and fatal disease caused by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). In general, the diagnostic tests for COVID-19 are based on the detection of nucleic acid, antibodies, and protein. Among different analytes, the gold standard of the COVID-19 test is the viral nucleic acid detection performed by the quantitative reverse transcription polymerase chain reaction (qRT-PCR) method. However, the gold standard test is time-consuming and requires expensive instrumentation, as well as trained personnel. Herein, we report an ultrasensitive electrochemical biosensor based on zinc sulfide/graphene (ZnS/graphene) nanocomposite for rapid and direct nucleic acid detection of SARS-CoV-2. We demonstrated a simple one-step route for manufacturing ZnS/graphene by employing an ultrafast (90 s) microwave-based non-equilibrium heating approach. The biosensor assay involves the hybridization of target DNA or RNA samples with probes that are immersed into a redox active electrolyte, which are detectable by electrochemical measurements. In this study, we have performed the tests for synthetic DNA samples and, SARS-CoV-2 standard samples. Experimental results revealed that the proposed biosensor could detect low concentrations of all different SARS-CoV-2 samples, using such as S, ORF 1a, and ORF 1b gene sequences as targets. This microwave-synthesized ZnS/graphene-based biosensor could be reliably used as an on-site, real-time, and rapid diagnostic test for COVID-19. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s42114-023-00630-7.
format Online
Article
Text
id pubmed-9879254
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Springer International Publishing
record_format MEDLINE/PubMed
spelling pubmed-98792542023-01-26 Ultrasensitive electrochemical biosensors based on zinc sulfide/graphene hybrid for rapid detection of SARS-CoV-2 Sarwar, Shatila Lin, Mao-Chia Amezaga, Carolina Wei, Zhen Iyayi, Etinosa Polk, Haseena Wang, Ruigang Wang, Honghe Zhang, Xinyu Adv Compos Hybrid Mater Research The coronavirus disease 2019 (COVID-19) is a highly contagious and fatal disease caused by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). In general, the diagnostic tests for COVID-19 are based on the detection of nucleic acid, antibodies, and protein. Among different analytes, the gold standard of the COVID-19 test is the viral nucleic acid detection performed by the quantitative reverse transcription polymerase chain reaction (qRT-PCR) method. However, the gold standard test is time-consuming and requires expensive instrumentation, as well as trained personnel. Herein, we report an ultrasensitive electrochemical biosensor based on zinc sulfide/graphene (ZnS/graphene) nanocomposite for rapid and direct nucleic acid detection of SARS-CoV-2. We demonstrated a simple one-step route for manufacturing ZnS/graphene by employing an ultrafast (90 s) microwave-based non-equilibrium heating approach. The biosensor assay involves the hybridization of target DNA or RNA samples with probes that are immersed into a redox active electrolyte, which are detectable by electrochemical measurements. In this study, we have performed the tests for synthetic DNA samples and, SARS-CoV-2 standard samples. Experimental results revealed that the proposed biosensor could detect low concentrations of all different SARS-CoV-2 samples, using such as S, ORF 1a, and ORF 1b gene sequences as targets. This microwave-synthesized ZnS/graphene-based biosensor could be reliably used as an on-site, real-time, and rapid diagnostic test for COVID-19. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s42114-023-00630-7. Springer International Publishing 2023-01-26 2023 /pmc/articles/PMC9879254/ /pubmed/36718472 http://dx.doi.org/10.1007/s42114-023-00630-7 Text en © The Author(s), under exclusive licence to Springer Nature Switzerland AG 2023, Springer Nature or its licensor (e.g. a society or other partner) holds exclusive rights to this article under a publishing agreement with the author(s) or other rightsholder(s); author self-archiving of the accepted manuscript version of this article is solely governed by the terms of such publishing agreement and applicable law. This article is made available via the PMC Open Access Subset for unrestricted research re-use and secondary analysis in any form or by any means with acknowledgement of the original source. These permissions are granted for the duration of the World Health Organization (WHO) declaration of COVID-19 as a global pandemic.
spellingShingle Research
Sarwar, Shatila
Lin, Mao-Chia
Amezaga, Carolina
Wei, Zhen
Iyayi, Etinosa
Polk, Haseena
Wang, Ruigang
Wang, Honghe
Zhang, Xinyu
Ultrasensitive electrochemical biosensors based on zinc sulfide/graphene hybrid for rapid detection of SARS-CoV-2
title Ultrasensitive electrochemical biosensors based on zinc sulfide/graphene hybrid for rapid detection of SARS-CoV-2
title_full Ultrasensitive electrochemical biosensors based on zinc sulfide/graphene hybrid for rapid detection of SARS-CoV-2
title_fullStr Ultrasensitive electrochemical biosensors based on zinc sulfide/graphene hybrid for rapid detection of SARS-CoV-2
title_full_unstemmed Ultrasensitive electrochemical biosensors based on zinc sulfide/graphene hybrid for rapid detection of SARS-CoV-2
title_short Ultrasensitive electrochemical biosensors based on zinc sulfide/graphene hybrid for rapid detection of SARS-CoV-2
title_sort ultrasensitive electrochemical biosensors based on zinc sulfide/graphene hybrid for rapid detection of sars-cov-2
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9879254/
https://www.ncbi.nlm.nih.gov/pubmed/36718472
http://dx.doi.org/10.1007/s42114-023-00630-7
work_keys_str_mv AT sarwarshatila ultrasensitiveelectrochemicalbiosensorsbasedonzincsulfidegraphenehybridforrapiddetectionofsarscov2
AT linmaochia ultrasensitiveelectrochemicalbiosensorsbasedonzincsulfidegraphenehybridforrapiddetectionofsarscov2
AT amezagacarolina ultrasensitiveelectrochemicalbiosensorsbasedonzincsulfidegraphenehybridforrapiddetectionofsarscov2
AT weizhen ultrasensitiveelectrochemicalbiosensorsbasedonzincsulfidegraphenehybridforrapiddetectionofsarscov2
AT iyayietinosa ultrasensitiveelectrochemicalbiosensorsbasedonzincsulfidegraphenehybridforrapiddetectionofsarscov2
AT polkhaseena ultrasensitiveelectrochemicalbiosensorsbasedonzincsulfidegraphenehybridforrapiddetectionofsarscov2
AT wangruigang ultrasensitiveelectrochemicalbiosensorsbasedonzincsulfidegraphenehybridforrapiddetectionofsarscov2
AT wanghonghe ultrasensitiveelectrochemicalbiosensorsbasedonzincsulfidegraphenehybridforrapiddetectionofsarscov2
AT zhangxinyu ultrasensitiveelectrochemicalbiosensorsbasedonzincsulfidegraphenehybridforrapiddetectionofsarscov2