Cargando…
Myoelectric prosthesis hand grasp control following targeted muscle reinnervation in individuals with transradial amputation
BACKGROUND: Despite the growing availability of multifunctional prosthetic hands, users’ control and overall functional abilities with these hands remain limited. The combination of pattern recognition control and targeted muscle reinnervation (TMR) surgery, an innovative technique where amputated n...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9879512/ https://www.ncbi.nlm.nih.gov/pubmed/36701412 http://dx.doi.org/10.1371/journal.pone.0280210 |
_version_ | 1784878707007029248 |
---|---|
author | Simon, Ann M. Turner, Kristi L. Miller, Laura A. Dumanian, Gregory A. Potter, Benjamin K. Beachler, Mark D. Hargrove, Levi J. Kuiken, Todd A. |
author_facet | Simon, Ann M. Turner, Kristi L. Miller, Laura A. Dumanian, Gregory A. Potter, Benjamin K. Beachler, Mark D. Hargrove, Levi J. Kuiken, Todd A. |
author_sort | Simon, Ann M. |
collection | PubMed |
description | BACKGROUND: Despite the growing availability of multifunctional prosthetic hands, users’ control and overall functional abilities with these hands remain limited. The combination of pattern recognition control and targeted muscle reinnervation (TMR) surgery, an innovative technique where amputated nerves are transferred to reinnervate new muscle targets in the residual limb, has been used to improve prosthesis control of individuals with more proximal upper limb amputations (i.e., shoulder disarticulation and transhumeral amputation). OBJECTIVE: The goal of this study was to determine if prosthesis hand grasp control improves following transradial TMR surgery. METHODS: Eight participants were trained to use a multi-articulating hand prosthesis under myoelectric pattern recognition control. All participated in home usage trials pre- and post-TMR surgery. Upper limb outcome measures were collected following each home trial. RESULTS: Three outcome measures (Southampton Hand Assessment Procedure, Jebsen-Taylor Hand Function Test, and Box and Blocks Test) improved 9–12 months post-TMR surgery compared with pre-surgery measures. The Assessment of Capacity for Myoelectric Control and Activities Measure for Upper Limb Amputees outcome measures had no difference pre- and post-surgery. An offline electromyography analysis showed a decrease in grip classification error post-TMR surgery compared to pre-TMR surgery. Additionally, a majority of subjects noted qualitative improvements in their residual limb and phantom limb sensations post-TMR. CONCLUSIONS: The potential for TMR surgery to result in more repeatable muscle contractions, possibly due to the reduction in pain levels and/or changes to phantom limb sensations, may increase functional use of many of the clinically available dexterous prosthetic hands. |
format | Online Article Text |
id | pubmed-9879512 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-98795122023-01-27 Myoelectric prosthesis hand grasp control following targeted muscle reinnervation in individuals with transradial amputation Simon, Ann M. Turner, Kristi L. Miller, Laura A. Dumanian, Gregory A. Potter, Benjamin K. Beachler, Mark D. Hargrove, Levi J. Kuiken, Todd A. PLoS One Research Article BACKGROUND: Despite the growing availability of multifunctional prosthetic hands, users’ control and overall functional abilities with these hands remain limited. The combination of pattern recognition control and targeted muscle reinnervation (TMR) surgery, an innovative technique where amputated nerves are transferred to reinnervate new muscle targets in the residual limb, has been used to improve prosthesis control of individuals with more proximal upper limb amputations (i.e., shoulder disarticulation and transhumeral amputation). OBJECTIVE: The goal of this study was to determine if prosthesis hand grasp control improves following transradial TMR surgery. METHODS: Eight participants were trained to use a multi-articulating hand prosthesis under myoelectric pattern recognition control. All participated in home usage trials pre- and post-TMR surgery. Upper limb outcome measures were collected following each home trial. RESULTS: Three outcome measures (Southampton Hand Assessment Procedure, Jebsen-Taylor Hand Function Test, and Box and Blocks Test) improved 9–12 months post-TMR surgery compared with pre-surgery measures. The Assessment of Capacity for Myoelectric Control and Activities Measure for Upper Limb Amputees outcome measures had no difference pre- and post-surgery. An offline electromyography analysis showed a decrease in grip classification error post-TMR surgery compared to pre-TMR surgery. Additionally, a majority of subjects noted qualitative improvements in their residual limb and phantom limb sensations post-TMR. CONCLUSIONS: The potential for TMR surgery to result in more repeatable muscle contractions, possibly due to the reduction in pain levels and/or changes to phantom limb sensations, may increase functional use of many of the clinically available dexterous prosthetic hands. Public Library of Science 2023-01-26 /pmc/articles/PMC9879512/ /pubmed/36701412 http://dx.doi.org/10.1371/journal.pone.0280210 Text en © 2023 Simon et al https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. |
spellingShingle | Research Article Simon, Ann M. Turner, Kristi L. Miller, Laura A. Dumanian, Gregory A. Potter, Benjamin K. Beachler, Mark D. Hargrove, Levi J. Kuiken, Todd A. Myoelectric prosthesis hand grasp control following targeted muscle reinnervation in individuals with transradial amputation |
title | Myoelectric prosthesis hand grasp control following targeted muscle reinnervation in individuals with transradial amputation |
title_full | Myoelectric prosthesis hand grasp control following targeted muscle reinnervation in individuals with transradial amputation |
title_fullStr | Myoelectric prosthesis hand grasp control following targeted muscle reinnervation in individuals with transradial amputation |
title_full_unstemmed | Myoelectric prosthesis hand grasp control following targeted muscle reinnervation in individuals with transradial amputation |
title_short | Myoelectric prosthesis hand grasp control following targeted muscle reinnervation in individuals with transradial amputation |
title_sort | myoelectric prosthesis hand grasp control following targeted muscle reinnervation in individuals with transradial amputation |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9879512/ https://www.ncbi.nlm.nih.gov/pubmed/36701412 http://dx.doi.org/10.1371/journal.pone.0280210 |
work_keys_str_mv | AT simonannm myoelectricprosthesishandgraspcontrolfollowingtargetedmusclereinnervationinindividualswithtransradialamputation AT turnerkristil myoelectricprosthesishandgraspcontrolfollowingtargetedmusclereinnervationinindividualswithtransradialamputation AT millerlauraa myoelectricprosthesishandgraspcontrolfollowingtargetedmusclereinnervationinindividualswithtransradialamputation AT dumaniangregorya myoelectricprosthesishandgraspcontrolfollowingtargetedmusclereinnervationinindividualswithtransradialamputation AT potterbenjamink myoelectricprosthesishandgraspcontrolfollowingtargetedmusclereinnervationinindividualswithtransradialamputation AT beachlermarkd myoelectricprosthesishandgraspcontrolfollowingtargetedmusclereinnervationinindividualswithtransradialamputation AT hargrovelevij myoelectricprosthesishandgraspcontrolfollowingtargetedmusclereinnervationinindividualswithtransradialamputation AT kuikentodda myoelectricprosthesishandgraspcontrolfollowingtargetedmusclereinnervationinindividualswithtransradialamputation |