Cargando…

Quantitative perfusion assessment using indocyanine green during surgery — current applications and recommendations for future use

PURPOSE: Incorrect assessment of tissue perfusion carries a significant risk of complications in surgery. The use of near-infrared (NIR) fluorescence imaging with Indocyanine Green (ICG) presents a possible solution. However, only through quantification of the fluorescence signal can an objective an...

Descripción completa

Detalles Bibliográficos
Autores principales: Van Den Hoven, P., Osterkamp, J., Nerup, N., Svendsen, M. B. S., Vahrmeijer, Alexander, Van Der Vorst, J. R., Achiam, M. P.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Berlin Heidelberg 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9879827/
https://www.ncbi.nlm.nih.gov/pubmed/36700999
http://dx.doi.org/10.1007/s00423-023-02780-0
Descripción
Sumario:PURPOSE: Incorrect assessment of tissue perfusion carries a significant risk of complications in surgery. The use of near-infrared (NIR) fluorescence imaging with Indocyanine Green (ICG) presents a possible solution. However, only through quantification of the fluorescence signal can an objective and reproducible evaluation of tissue perfusion be obtained. This narrative review aims to provide an overview of the available quantification methods for perfusion assessment using ICG NIR fluorescence imaging and to present an overview of current clinically utilized software implementations. METHODS: PubMed was searched for clinical studies on the quantification of ICG NIR fluorescence imaging to assess tissue perfusion. Data on the utilized camera systems and performed methods of quantification were collected. RESULTS: Eleven software programs for quantifying tissue perfusion using ICG NIR fluorescence imaging were identified. Five of the 11 programs have been described in three or more clinical studies, including Flow® 800, ROIs Software, IC Calc, SPY-Q™, and the Quest Research Framework®. In addition, applying normalization to fluorescence intensity analysis was described for two software programs. CONCLUSION: Several systems or software solutions provide a quantification of ICG fluorescence; however, intraoperative applications are scarce and quantification methods vary abundantly. In the widespread search for reliable quantification of perfusion with ICG NIR fluorescence imaging, standardization of quantification methods and data acquisition is essential. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s00423-023-02780-0.