Computed Tomography Evaluation of Percutaneous Pedicle Screws Inserted during Minimally Invasive Transforaminal Lumbar Interbody Fusion: Long-term Follow-up Results of Screw Violation
BACKGROUND: To evaluate the accuracy of percutaneous pedicle screw (PPS) insertion in degenerative lumbar disease treated with minimally invasive transforaminal lumbar interbody fusion (MI-TLIF) and to analyze risk factors and long-term clinical outcomes of screw violation. METHODS: Sixty-two consec...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Korean Orthopaedic Association
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9880512/ https://www.ncbi.nlm.nih.gov/pubmed/36778999 http://dx.doi.org/10.4055/cios21229 |
_version_ | 1784878929113251840 |
---|---|
author | Lee, Jae Chul Jang, Hae-Dong Choi, Sung-Woo Shin, Byung-Joon |
author_facet | Lee, Jae Chul Jang, Hae-Dong Choi, Sung-Woo Shin, Byung-Joon |
author_sort | Lee, Jae Chul |
collection | PubMed |
description | BACKGROUND: To evaluate the accuracy of percutaneous pedicle screw (PPS) insertion in degenerative lumbar disease treated with minimally invasive transforaminal lumbar interbody fusion (MI-TLIF) and to analyze risk factors and long-term clinical outcomes of screw violation. METHODS: Sixty-two consecutive patients (262 screws) were included. Based on postoperative computed tomography (CT) axial images, a PPS that perforated out of the pedicle was classified into a violation group, while screws surrounded by pedicular cortical bone were classified into a correct group. A logistic regression model was used for risk factor analysis of violation. We also observed the long-term clinical outcomes using the Oswestry disability index and visual analog scale. RESULTS: Of the 262 screws, 14 (5.3%) were considered to be violated (10 medial violations and 4 lateral violations). All violations of S1 and L5 were in the medial direction. In contrast, entire violations of L4 were always lateral and of the 2 violations of L3, one was lateral and the other was medial. There were no cases of superior or inferior violation. The mean pedicle convergence angle (CA) was significantly higher in the violation group (mean ± standard deviation, 27.0° ± 6.2°) than in the correct group (21.7° ± 5.4°). There were no significant differences according to vertebral rotational angle, body mass index, bone mineral density, and surgical timing (learning curve) between the two groups. Logistic regression analyses demonstrated that a high CA was a significant risk factor for pedicle wall violation (p = 0.002). There were no significant differences in clinical or radiographic results between the two groups in 60 patients who were followed up for more than 1 year and in 40 patients who were followed up for more than 5 years. There were 2 patients who required reoperation to replace a screw due to leg pain. CONCLUSIONS: With PPS insertion during MI-TLIF, the rate of pedicle violation was 5.3% (14/262). An understanding of the anatomical characteristics of each vertebra and the unique structures of the patient is essential to prevent pedicle violations. Even in the violation group, PPS fixation was found to be a safe and useful procedure with successful long-term radiographic and clinical outcomes. |
format | Online Article Text |
id | pubmed-9880512 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | The Korean Orthopaedic Association |
record_format | MEDLINE/PubMed |
spelling | pubmed-98805122023-02-09 Computed Tomography Evaluation of Percutaneous Pedicle Screws Inserted during Minimally Invasive Transforaminal Lumbar Interbody Fusion: Long-term Follow-up Results of Screw Violation Lee, Jae Chul Jang, Hae-Dong Choi, Sung-Woo Shin, Byung-Joon Clin Orthop Surg Original Article BACKGROUND: To evaluate the accuracy of percutaneous pedicle screw (PPS) insertion in degenerative lumbar disease treated with minimally invasive transforaminal lumbar interbody fusion (MI-TLIF) and to analyze risk factors and long-term clinical outcomes of screw violation. METHODS: Sixty-two consecutive patients (262 screws) were included. Based on postoperative computed tomography (CT) axial images, a PPS that perforated out of the pedicle was classified into a violation group, while screws surrounded by pedicular cortical bone were classified into a correct group. A logistic regression model was used for risk factor analysis of violation. We also observed the long-term clinical outcomes using the Oswestry disability index and visual analog scale. RESULTS: Of the 262 screws, 14 (5.3%) were considered to be violated (10 medial violations and 4 lateral violations). All violations of S1 and L5 were in the medial direction. In contrast, entire violations of L4 were always lateral and of the 2 violations of L3, one was lateral and the other was medial. There were no cases of superior or inferior violation. The mean pedicle convergence angle (CA) was significantly higher in the violation group (mean ± standard deviation, 27.0° ± 6.2°) than in the correct group (21.7° ± 5.4°). There were no significant differences according to vertebral rotational angle, body mass index, bone mineral density, and surgical timing (learning curve) between the two groups. Logistic regression analyses demonstrated that a high CA was a significant risk factor for pedicle wall violation (p = 0.002). There were no significant differences in clinical or radiographic results between the two groups in 60 patients who were followed up for more than 1 year and in 40 patients who were followed up for more than 5 years. There were 2 patients who required reoperation to replace a screw due to leg pain. CONCLUSIONS: With PPS insertion during MI-TLIF, the rate of pedicle violation was 5.3% (14/262). An understanding of the anatomical characteristics of each vertebra and the unique structures of the patient is essential to prevent pedicle violations. Even in the violation group, PPS fixation was found to be a safe and useful procedure with successful long-term radiographic and clinical outcomes. The Korean Orthopaedic Association 2023-02 2022-08-19 /pmc/articles/PMC9880512/ /pubmed/36778999 http://dx.doi.org/10.4055/cios21229 Text en Copyright © 2023 by The Korean Orthopaedic Association https://creativecommons.org/licenses/by-nc/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0 (https://creativecommons.org/licenses/by-nc/4.0/) ) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Lee, Jae Chul Jang, Hae-Dong Choi, Sung-Woo Shin, Byung-Joon Computed Tomography Evaluation of Percutaneous Pedicle Screws Inserted during Minimally Invasive Transforaminal Lumbar Interbody Fusion: Long-term Follow-up Results of Screw Violation |
title | Computed Tomography Evaluation of Percutaneous Pedicle Screws Inserted during Minimally Invasive Transforaminal Lumbar Interbody Fusion: Long-term Follow-up Results of Screw Violation |
title_full | Computed Tomography Evaluation of Percutaneous Pedicle Screws Inserted during Minimally Invasive Transforaminal Lumbar Interbody Fusion: Long-term Follow-up Results of Screw Violation |
title_fullStr | Computed Tomography Evaluation of Percutaneous Pedicle Screws Inserted during Minimally Invasive Transforaminal Lumbar Interbody Fusion: Long-term Follow-up Results of Screw Violation |
title_full_unstemmed | Computed Tomography Evaluation of Percutaneous Pedicle Screws Inserted during Minimally Invasive Transforaminal Lumbar Interbody Fusion: Long-term Follow-up Results of Screw Violation |
title_short | Computed Tomography Evaluation of Percutaneous Pedicle Screws Inserted during Minimally Invasive Transforaminal Lumbar Interbody Fusion: Long-term Follow-up Results of Screw Violation |
title_sort | computed tomography evaluation of percutaneous pedicle screws inserted during minimally invasive transforaminal lumbar interbody fusion: long-term follow-up results of screw violation |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9880512/ https://www.ncbi.nlm.nih.gov/pubmed/36778999 http://dx.doi.org/10.4055/cios21229 |
work_keys_str_mv | AT leejaechul computedtomographyevaluationofpercutaneouspediclescrewsinsertedduringminimallyinvasivetransforaminallumbarinterbodyfusionlongtermfollowupresultsofscrewviolation AT janghaedong computedtomographyevaluationofpercutaneouspediclescrewsinsertedduringminimallyinvasivetransforaminallumbarinterbodyfusionlongtermfollowupresultsofscrewviolation AT choisungwoo computedtomographyevaluationofpercutaneouspediclescrewsinsertedduringminimallyinvasivetransforaminallumbarinterbodyfusionlongtermfollowupresultsofscrewviolation AT shinbyungjoon computedtomographyevaluationofpercutaneouspediclescrewsinsertedduringminimallyinvasivetransforaminallumbarinterbodyfusionlongtermfollowupresultsofscrewviolation |