Cargando…
Validity and reproducibility of retinal arteriole and venule diameter measurements: ELSA-Brasil study. A cross-sectional study
BACKGROUND: Investigation of alterations to retinal microvasculature may contribute towards understanding the role of such changes in the pathophysiology of several chronic non-communicable diseases. The objective here was to evaluate the validity and reproducibility of retinal arteriole and venule...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Associação Paulista de Medicina - APM
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9881697/ https://www.ncbi.nlm.nih.gov/pubmed/30304202 http://dx.doi.org/10.1590/1516-3180.2018.0227230718 |
_version_ | 1784879165529391104 |
---|---|
author | Dartora, William Jones Maestri, Marcelo Krieger Schmidt, Maria Inês Duncan, Bruce Bartholow Chambless, Lloyd Klein, Ronald Meuer, Stacy Luft, Vivian Cristine |
author_facet | Dartora, William Jones Maestri, Marcelo Krieger Schmidt, Maria Inês Duncan, Bruce Bartholow Chambless, Lloyd Klein, Ronald Meuer, Stacy Luft, Vivian Cristine |
author_sort | Dartora, William Jones |
collection | PubMed |
description | BACKGROUND: Investigation of alterations to retinal microvasculature may contribute towards understanding the role of such changes in the pathophysiology of several chronic non-communicable diseases. The objective here was to evaluate the validity and reproducibility of retinal arteriole and venule diameter measurements made by Brazilian Longitudinal Study of Adult Health (ELSA-Brasil) graders. DESIGN AND SETTING: Cross-sectional study at six teaching and research institutions. METHODS: To evaluate validity, each of 25 retinal images from the University of Wisconsin (gold standard) was measured by five ELSA-Brasil graders. To evaluate reproducibility, 105 images across the spectrum of vessel diameters were selected from 12,257 retinal images that had been obtained between 2010 and 2012, and each image was reexamined by the same grader and by an independent grader. All measurements were made using the Interactive Vessel Analysis (IVAN) software. Bland-Altman plots, paired t tests and intraclass correlation coefficients (ICCs) were analyzed. RESULTS: Mean differences between ELSA-Brasil and gold-standard readings were 0.16 µm (95% CI -0.17-0.50; P = 0.31) for central retinal artery equivalent (CRAE), -0.21 µm (95% CI -0.56-0.14; P = 0.22) for central retinal vein equivalent (CRVE) and 0.0005 (95% CI -0.008-0.009; P = 0.55) for arteriole/venule ratio (AVR). Intragrader ICCs were 0.77 (95% CI 0.67-0.86) for CRAE, 0.90 (95% CI 0.780.96) for CRVE and 0.70 (0.55-0.83) for AVR. Intergrader ICCs were 0.75 (95% CI 0.64-0.85) for CRAE, 0.90 (95% CI 0.79-0.96) for CRVE and 0.68 (95% CI 0.55-0.82) for AVR. CONCLUSIONS: Retinal microvascular diameter measurements are valid and present moderate to high intra and intergrader reproducibility in ELSA-Brasil. |
format | Online Article Text |
id | pubmed-9881697 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | Associação Paulista de Medicina - APM |
record_format | MEDLINE/PubMed |
spelling | pubmed-98816972023-01-31 Validity and reproducibility of retinal arteriole and venule diameter measurements: ELSA-Brasil study. A cross-sectional study Dartora, William Jones Maestri, Marcelo Krieger Schmidt, Maria Inês Duncan, Bruce Bartholow Chambless, Lloyd Klein, Ronald Meuer, Stacy Luft, Vivian Cristine Sao Paulo Med J Original Article BACKGROUND: Investigation of alterations to retinal microvasculature may contribute towards understanding the role of such changes in the pathophysiology of several chronic non-communicable diseases. The objective here was to evaluate the validity and reproducibility of retinal arteriole and venule diameter measurements made by Brazilian Longitudinal Study of Adult Health (ELSA-Brasil) graders. DESIGN AND SETTING: Cross-sectional study at six teaching and research institutions. METHODS: To evaluate validity, each of 25 retinal images from the University of Wisconsin (gold standard) was measured by five ELSA-Brasil graders. To evaluate reproducibility, 105 images across the spectrum of vessel diameters were selected from 12,257 retinal images that had been obtained between 2010 and 2012, and each image was reexamined by the same grader and by an independent grader. All measurements were made using the Interactive Vessel Analysis (IVAN) software. Bland-Altman plots, paired t tests and intraclass correlation coefficients (ICCs) were analyzed. RESULTS: Mean differences between ELSA-Brasil and gold-standard readings were 0.16 µm (95% CI -0.17-0.50; P = 0.31) for central retinal artery equivalent (CRAE), -0.21 µm (95% CI -0.56-0.14; P = 0.22) for central retinal vein equivalent (CRVE) and 0.0005 (95% CI -0.008-0.009; P = 0.55) for arteriole/venule ratio (AVR). Intragrader ICCs were 0.77 (95% CI 0.67-0.86) for CRAE, 0.90 (95% CI 0.780.96) for CRVE and 0.70 (0.55-0.83) for AVR. Intergrader ICCs were 0.75 (95% CI 0.64-0.85) for CRAE, 0.90 (95% CI 0.79-0.96) for CRVE and 0.68 (95% CI 0.55-0.82) for AVR. CONCLUSIONS: Retinal microvascular diameter measurements are valid and present moderate to high intra and intergrader reproducibility in ELSA-Brasil. Associação Paulista de Medicina - APM 2018-07-21 /pmc/articles/PMC9881697/ /pubmed/30304202 http://dx.doi.org/10.1590/1516-3180.2018.0227230718 Text en © 2022 by Associação Paulista de Medicina https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the terms of the Creative Commons license. |
spellingShingle | Original Article Dartora, William Jones Maestri, Marcelo Krieger Schmidt, Maria Inês Duncan, Bruce Bartholow Chambless, Lloyd Klein, Ronald Meuer, Stacy Luft, Vivian Cristine Validity and reproducibility of retinal arteriole and venule diameter measurements: ELSA-Brasil study. A cross-sectional study |
title | Validity and reproducibility of retinal arteriole and venule diameter measurements: ELSA-Brasil study. A cross-sectional study |
title_full | Validity and reproducibility of retinal arteriole and venule diameter measurements: ELSA-Brasil study. A cross-sectional study |
title_fullStr | Validity and reproducibility of retinal arteriole and venule diameter measurements: ELSA-Brasil study. A cross-sectional study |
title_full_unstemmed | Validity and reproducibility of retinal arteriole and venule diameter measurements: ELSA-Brasil study. A cross-sectional study |
title_short | Validity and reproducibility of retinal arteriole and venule diameter measurements: ELSA-Brasil study. A cross-sectional study |
title_sort | validity and reproducibility of retinal arteriole and venule diameter measurements: elsa-brasil study. a cross-sectional study |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9881697/ https://www.ncbi.nlm.nih.gov/pubmed/30304202 http://dx.doi.org/10.1590/1516-3180.2018.0227230718 |
work_keys_str_mv | AT dartorawilliamjones validityandreproducibilityofretinalarterioleandvenulediametermeasurementselsabrasilstudyacrosssectionalstudy AT maestrimarcelokrieger validityandreproducibilityofretinalarterioleandvenulediametermeasurementselsabrasilstudyacrosssectionalstudy AT schmidtmariaines validityandreproducibilityofretinalarterioleandvenulediametermeasurementselsabrasilstudyacrosssectionalstudy AT duncanbrucebartholow validityandreproducibilityofretinalarterioleandvenulediametermeasurementselsabrasilstudyacrosssectionalstudy AT chamblesslloyd validityandreproducibilityofretinalarterioleandvenulediametermeasurementselsabrasilstudyacrosssectionalstudy AT kleinronald validityandreproducibilityofretinalarterioleandvenulediametermeasurementselsabrasilstudyacrosssectionalstudy AT meuerstacy validityandreproducibilityofretinalarterioleandvenulediametermeasurementselsabrasilstudyacrosssectionalstudy AT luftviviancristine validityandreproducibilityofretinalarterioleandvenulediametermeasurementselsabrasilstudyacrosssectionalstudy |