Cargando…
The angle of the tines before the pull and hold test predicts engagement of the tines in Micra leadless pacemaker implantation
BACKGROUND: Micra leadless pacemaker is secured to the myocardium by engagement of at least 2/4 tines confirmed with pull and hold test. However, the pull and hold test is sometimes difficult to assess. This study was performed to evaluate whether the angle of the tines before the pull and hold test...
Autores principales: | , , , , , , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
John Wiley and Sons Inc.
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9885318/ https://www.ncbi.nlm.nih.gov/pubmed/36733332 http://dx.doi.org/10.1002/joa3.12797 |
_version_ | 1784879910456655872 |
---|---|
author | Mizukami, Akira Miyakuni, Shota Nakada, Ryo Kobayashi, Tetsuya Kawakami, Takuya Takegawa, Koki Arai, Hirofumi Hiroki, Jiro Yoshioka, Kenji Otani, Hirofumi Ono, Maki Yamashita, Shu Ueshima, Daisuke Suzuki, Makoto Matsumura, Akihiko Goya, Masahiko Sasano, Tetsuo |
author_facet | Mizukami, Akira Miyakuni, Shota Nakada, Ryo Kobayashi, Tetsuya Kawakami, Takuya Takegawa, Koki Arai, Hirofumi Hiroki, Jiro Yoshioka, Kenji Otani, Hirofumi Ono, Maki Yamashita, Shu Ueshima, Daisuke Suzuki, Makoto Matsumura, Akihiko Goya, Masahiko Sasano, Tetsuo |
author_sort | Mizukami, Akira |
collection | PubMed |
description | BACKGROUND: Micra leadless pacemaker is secured to the myocardium by engagement of at least 2/4 tines confirmed with pull and hold test. However, the pull and hold test is sometimes difficult to assess. This study was performed to evaluate whether the angle of the tines before the pull and hold test predicts engagement of the tines in Micra leadless pacemaker implantation. METHODS: We retrospectively enrolled 93 consecutive patients (52.7% male, age 82.4 ± 9.4 years), who received Micra implantation from September 2017 to June 2020 at our institution. After deployment and before the pull and hold test, the angle of the visible tines to the body of the pacemaker was measured using the RAO view of the fluoroscopy image. The engagement of the tines was then confirmed with the pull and hold test. RESULTS: A total of 326 tines were analyzed. The angle of the engaged tines was significantly lower than the non‐engaged tines (9.2 degrees [4.0–14.0] vs. 16.6 degrees [14.2–18.8], p < .0001). All tines with angles <10 degrees were engaged. In higher angles, engagement could not be predicted. CONCLUSION: A low angle of the tines before the pull and hold test can predict engagement of the tines in Micra leadless pacemaker implantation. The tines which are already open after deployment may be presumed that they are engaged. |
format | Online Article Text |
id | pubmed-9885318 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | John Wiley and Sons Inc. |
record_format | MEDLINE/PubMed |
spelling | pubmed-98853182023-02-01 The angle of the tines before the pull and hold test predicts engagement of the tines in Micra leadless pacemaker implantation Mizukami, Akira Miyakuni, Shota Nakada, Ryo Kobayashi, Tetsuya Kawakami, Takuya Takegawa, Koki Arai, Hirofumi Hiroki, Jiro Yoshioka, Kenji Otani, Hirofumi Ono, Maki Yamashita, Shu Ueshima, Daisuke Suzuki, Makoto Matsumura, Akihiko Goya, Masahiko Sasano, Tetsuo J Arrhythm Original Articles BACKGROUND: Micra leadless pacemaker is secured to the myocardium by engagement of at least 2/4 tines confirmed with pull and hold test. However, the pull and hold test is sometimes difficult to assess. This study was performed to evaluate whether the angle of the tines before the pull and hold test predicts engagement of the tines in Micra leadless pacemaker implantation. METHODS: We retrospectively enrolled 93 consecutive patients (52.7% male, age 82.4 ± 9.4 years), who received Micra implantation from September 2017 to June 2020 at our institution. After deployment and before the pull and hold test, the angle of the visible tines to the body of the pacemaker was measured using the RAO view of the fluoroscopy image. The engagement of the tines was then confirmed with the pull and hold test. RESULTS: A total of 326 tines were analyzed. The angle of the engaged tines was significantly lower than the non‐engaged tines (9.2 degrees [4.0–14.0] vs. 16.6 degrees [14.2–18.8], p < .0001). All tines with angles <10 degrees were engaged. In higher angles, engagement could not be predicted. CONCLUSION: A low angle of the tines before the pull and hold test can predict engagement of the tines in Micra leadless pacemaker implantation. The tines which are already open after deployment may be presumed that they are engaged. John Wiley and Sons Inc. 2022-11-23 /pmc/articles/PMC9885318/ /pubmed/36733332 http://dx.doi.org/10.1002/joa3.12797 Text en © 2022 The Authors. Journal of Arrhythmia published by John Wiley & Sons Australia, Ltd on behalf of Japanese Heart Rhythm Society. https://creativecommons.org/licenses/by/4.0/This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Articles Mizukami, Akira Miyakuni, Shota Nakada, Ryo Kobayashi, Tetsuya Kawakami, Takuya Takegawa, Koki Arai, Hirofumi Hiroki, Jiro Yoshioka, Kenji Otani, Hirofumi Ono, Maki Yamashita, Shu Ueshima, Daisuke Suzuki, Makoto Matsumura, Akihiko Goya, Masahiko Sasano, Tetsuo The angle of the tines before the pull and hold test predicts engagement of the tines in Micra leadless pacemaker implantation |
title | The angle of the tines before the pull and hold test predicts engagement of the tines in Micra leadless pacemaker implantation |
title_full | The angle of the tines before the pull and hold test predicts engagement of the tines in Micra leadless pacemaker implantation |
title_fullStr | The angle of the tines before the pull and hold test predicts engagement of the tines in Micra leadless pacemaker implantation |
title_full_unstemmed | The angle of the tines before the pull and hold test predicts engagement of the tines in Micra leadless pacemaker implantation |
title_short | The angle of the tines before the pull and hold test predicts engagement of the tines in Micra leadless pacemaker implantation |
title_sort | angle of the tines before the pull and hold test predicts engagement of the tines in micra leadless pacemaker implantation |
topic | Original Articles |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9885318/ https://www.ncbi.nlm.nih.gov/pubmed/36733332 http://dx.doi.org/10.1002/joa3.12797 |
work_keys_str_mv | AT mizukamiakira theangleofthetinesbeforethepullandholdtestpredictsengagementofthetinesinmicraleadlesspacemakerimplantation AT miyakunishota theangleofthetinesbeforethepullandholdtestpredictsengagementofthetinesinmicraleadlesspacemakerimplantation AT nakadaryo theangleofthetinesbeforethepullandholdtestpredictsengagementofthetinesinmicraleadlesspacemakerimplantation AT kobayashitetsuya theangleofthetinesbeforethepullandholdtestpredictsengagementofthetinesinmicraleadlesspacemakerimplantation AT kawakamitakuya theangleofthetinesbeforethepullandholdtestpredictsengagementofthetinesinmicraleadlesspacemakerimplantation AT takegawakoki theangleofthetinesbeforethepullandholdtestpredictsengagementofthetinesinmicraleadlesspacemakerimplantation AT araihirofumi theangleofthetinesbeforethepullandholdtestpredictsengagementofthetinesinmicraleadlesspacemakerimplantation AT hirokijiro theangleofthetinesbeforethepullandholdtestpredictsengagementofthetinesinmicraleadlesspacemakerimplantation AT yoshiokakenji theangleofthetinesbeforethepullandholdtestpredictsengagementofthetinesinmicraleadlesspacemakerimplantation AT otanihirofumi theangleofthetinesbeforethepullandholdtestpredictsengagementofthetinesinmicraleadlesspacemakerimplantation AT onomaki theangleofthetinesbeforethepullandholdtestpredictsengagementofthetinesinmicraleadlesspacemakerimplantation AT yamashitashu theangleofthetinesbeforethepullandholdtestpredictsengagementofthetinesinmicraleadlesspacemakerimplantation AT ueshimadaisuke theangleofthetinesbeforethepullandholdtestpredictsengagementofthetinesinmicraleadlesspacemakerimplantation AT suzukimakoto theangleofthetinesbeforethepullandholdtestpredictsengagementofthetinesinmicraleadlesspacemakerimplantation AT matsumuraakihiko theangleofthetinesbeforethepullandholdtestpredictsengagementofthetinesinmicraleadlesspacemakerimplantation AT goyamasahiko theangleofthetinesbeforethepullandholdtestpredictsengagementofthetinesinmicraleadlesspacemakerimplantation AT sasanotetsuo theangleofthetinesbeforethepullandholdtestpredictsengagementofthetinesinmicraleadlesspacemakerimplantation AT mizukamiakira angleofthetinesbeforethepullandholdtestpredictsengagementofthetinesinmicraleadlesspacemakerimplantation AT miyakunishota angleofthetinesbeforethepullandholdtestpredictsengagementofthetinesinmicraleadlesspacemakerimplantation AT nakadaryo angleofthetinesbeforethepullandholdtestpredictsengagementofthetinesinmicraleadlesspacemakerimplantation AT kobayashitetsuya angleofthetinesbeforethepullandholdtestpredictsengagementofthetinesinmicraleadlesspacemakerimplantation AT kawakamitakuya angleofthetinesbeforethepullandholdtestpredictsengagementofthetinesinmicraleadlesspacemakerimplantation AT takegawakoki angleofthetinesbeforethepullandholdtestpredictsengagementofthetinesinmicraleadlesspacemakerimplantation AT araihirofumi angleofthetinesbeforethepullandholdtestpredictsengagementofthetinesinmicraleadlesspacemakerimplantation AT hirokijiro angleofthetinesbeforethepullandholdtestpredictsengagementofthetinesinmicraleadlesspacemakerimplantation AT yoshiokakenji angleofthetinesbeforethepullandholdtestpredictsengagementofthetinesinmicraleadlesspacemakerimplantation AT otanihirofumi angleofthetinesbeforethepullandholdtestpredictsengagementofthetinesinmicraleadlesspacemakerimplantation AT onomaki angleofthetinesbeforethepullandholdtestpredictsengagementofthetinesinmicraleadlesspacemakerimplantation AT yamashitashu angleofthetinesbeforethepullandholdtestpredictsengagementofthetinesinmicraleadlesspacemakerimplantation AT ueshimadaisuke angleofthetinesbeforethepullandholdtestpredictsengagementofthetinesinmicraleadlesspacemakerimplantation AT suzukimakoto angleofthetinesbeforethepullandholdtestpredictsengagementofthetinesinmicraleadlesspacemakerimplantation AT matsumuraakihiko angleofthetinesbeforethepullandholdtestpredictsengagementofthetinesinmicraleadlesspacemakerimplantation AT goyamasahiko angleofthetinesbeforethepullandholdtestpredictsengagementofthetinesinmicraleadlesspacemakerimplantation AT sasanotetsuo angleofthetinesbeforethepullandholdtestpredictsengagementofthetinesinmicraleadlesspacemakerimplantation |