BACKGROUND: Every year, more than 2.5 million critically ill patients in the ICU are dependent on mechanical ventilation. The positive pressure in the lungs generated by the ventilator keeps the diaphragm passive, which can lead to a loss of myofibers within a short time. To prevent ventilator-induc...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9885573/ https://www.ncbi.nlm.nih.gov/pubmed/36717872 http://dx.doi.org/10.1186/s12938-023-01071-5 |
_version_ | 1784879956266844160 |
---|---|
author | Kaufmann, Elisa M. Krause, Sven Geisshuesler, Lukas Scheidegger, Olivier Haeberlin, Andreas Niederhauser, Thomas |
author_facet | Kaufmann, Elisa M. Krause, Sven Geisshuesler, Lukas Scheidegger, Olivier Haeberlin, Andreas Niederhauser, Thomas |
author_sort | Kaufmann, Elisa M. |
collection | PubMed |
description | BACKGROUND: Every year, more than 2.5 million critically ill patients in the ICU are dependent on mechanical ventilation. The positive pressure in the lungs generated by the ventilator keeps the diaphragm passive, which can lead to a loss of myofibers within a short time. To prevent ventilator-induced diaphragmatic dysfunction (VIDD), phrenic nerve stimulation may be used. OBJECTIVE: The goal of this study is to show the feasibility of transesophageal phrenic nerve stimulation (TEPNS). We hypothesize that selective phrenic nerve stimulation can efficiently activate the diaphragm with reduced co-stimulations. METHODS: An in vitro study in saline solution combined with anatomical findings was performed to investigate relevant stimulation parameters such as inter-electrode spacing, range to target site, or omnidirectional vs. sectioned electrodes. Subsequently, dedicated esophageal electrodes were inserted into a pig and single stimulation pulses were delivered simultaneously with mechanical ventilation. Various stimulation sites and response parameters such as transdiaphragmatic pressure or airway flow were analyzed to establish an appropriate stimulation setting. RESULTS: Phrenic nerve stimulation with esophageal electrodes has been demonstrated. With a current amplitude of 40 mA, similar response figures of the diaphragm activation as compared to conventional stimulation with needle electrodes at 10mA were observed. Directed electrodes best aligned with the phrenic nerve resulted in up to 16.9 % higher amplitude at the target site in vitro and up to 6 cmH20 higher transdiaphragmatic pressure in vivo as compared to omnidirectional electrodes. The activation efficiency was more sensitive to the stimulation level inside the esophagus than to the inter-electrode spacing. Most effective and selective stimulation was achieved at the level of rib 1 using sectioned electrodes 40 mm apart. CONCLUSION: Directed transesophageal phrenic nerve stimulation with single stimuli enabled diaphragm activation. In the future, this method might keep the diaphragm active during, and even support, artificial ventilation. Meanwhile, dedicated sectioned electrodes could be integrated into gastric feeding tubes. |
format | Online Article Text |
id | pubmed-9885573 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-98855732023-01-31 Feasibility of transesophageal phrenic nerve stimulation Kaufmann, Elisa M. Krause, Sven Geisshuesler, Lukas Scheidegger, Olivier Haeberlin, Andreas Niederhauser, Thomas Biomed Eng Online Research BACKGROUND: Every year, more than 2.5 million critically ill patients in the ICU are dependent on mechanical ventilation. The positive pressure in the lungs generated by the ventilator keeps the diaphragm passive, which can lead to a loss of myofibers within a short time. To prevent ventilator-induced diaphragmatic dysfunction (VIDD), phrenic nerve stimulation may be used. OBJECTIVE: The goal of this study is to show the feasibility of transesophageal phrenic nerve stimulation (TEPNS). We hypothesize that selective phrenic nerve stimulation can efficiently activate the diaphragm with reduced co-stimulations. METHODS: An in vitro study in saline solution combined with anatomical findings was performed to investigate relevant stimulation parameters such as inter-electrode spacing, range to target site, or omnidirectional vs. sectioned electrodes. Subsequently, dedicated esophageal electrodes were inserted into a pig and single stimulation pulses were delivered simultaneously with mechanical ventilation. Various stimulation sites and response parameters such as transdiaphragmatic pressure or airway flow were analyzed to establish an appropriate stimulation setting. RESULTS: Phrenic nerve stimulation with esophageal electrodes has been demonstrated. With a current amplitude of 40 mA, similar response figures of the diaphragm activation as compared to conventional stimulation with needle electrodes at 10mA were observed. Directed electrodes best aligned with the phrenic nerve resulted in up to 16.9 % higher amplitude at the target site in vitro and up to 6 cmH20 higher transdiaphragmatic pressure in vivo as compared to omnidirectional electrodes. The activation efficiency was more sensitive to the stimulation level inside the esophagus than to the inter-electrode spacing. Most effective and selective stimulation was achieved at the level of rib 1 using sectioned electrodes 40 mm apart. CONCLUSION: Directed transesophageal phrenic nerve stimulation with single stimuli enabled diaphragm activation. In the future, this method might keep the diaphragm active during, and even support, artificial ventilation. Meanwhile, dedicated sectioned electrodes could be integrated into gastric feeding tubes. BioMed Central 2023-01-30 /pmc/articles/PMC9885573/ /pubmed/36717872 http://dx.doi.org/10.1186/s12938-023-01071-5 Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Research Kaufmann, Elisa M. Krause, Sven Geisshuesler, Lukas Scheidegger, Olivier Haeberlin, Andreas Niederhauser, Thomas Feasibility of transesophageal phrenic nerve stimulation |
title | Feasibility of transesophageal phrenic nerve stimulation |
title_full | Feasibility of transesophageal phrenic nerve stimulation |
title_fullStr | Feasibility of transesophageal phrenic nerve stimulation |
title_full_unstemmed | Feasibility of transesophageal phrenic nerve stimulation |
title_short | Feasibility of transesophageal phrenic nerve stimulation |
title_sort | feasibility of transesophageal phrenic nerve stimulation |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9885573/ https://www.ncbi.nlm.nih.gov/pubmed/36717872 http://dx.doi.org/10.1186/s12938-023-01071-5 |
work_keys_str_mv | AT kaufmannelisam feasibilityoftransesophagealphrenicnervestimulation AT krausesven feasibilityoftransesophagealphrenicnervestimulation AT geisshueslerlukas feasibilityoftransesophagealphrenicnervestimulation AT scheideggerolivier feasibilityoftransesophagealphrenicnervestimulation AT haeberlinandreas feasibilityoftransesophagealphrenicnervestimulation AT niederhauserthomas feasibilityoftransesophagealphrenicnervestimulation |