Cargando…

Clinical evaluation of marginal fit of uncemented CAD-CAM monolithic zirconia three-unit restorations in anterior areas, using scannable and conventional polyvinyl siloxane impression materials

BACKGROUND: The accuracy of impression techniques determines the marginal fit of fixed prostheses. Marginal accuracy plays a main role in the success and failure of treatments. This in-vivo study evaluated the marginal fit of anterior three-unit monolithic zirconia fixed partial dentures (FPDs) usin...

Descripción completa

Detalles Bibliográficos
Autores principales: Kalantari, Mohammad Hassan, Abbasi, Benika, Giti, Rashin, Rastegar, Zahra, Tavanafar, Saeid, Shahsavari-pour, Sheila
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9885647/
https://www.ncbi.nlm.nih.gov/pubmed/36717822
http://dx.doi.org/10.1186/s12903-023-02771-z
_version_ 1784879972186324992
author Kalantari, Mohammad Hassan
Abbasi, Benika
Giti, Rashin
Rastegar, Zahra
Tavanafar, Saeid
Shahsavari-pour, Sheila
author_facet Kalantari, Mohammad Hassan
Abbasi, Benika
Giti, Rashin
Rastegar, Zahra
Tavanafar, Saeid
Shahsavari-pour, Sheila
author_sort Kalantari, Mohammad Hassan
collection PubMed
description BACKGROUND: The accuracy of impression techniques determines the marginal fit of fixed prostheses. Marginal accuracy plays a main role in the success and failure of treatments. This in-vivo study evaluated the marginal fit of anterior three-unit monolithic zirconia fixed partial dentures (FPDs) using conventional and scannable polyvinyl siloxane impression materials. METHODS: Ten patients were selected to replace the lateral teeth with a three-unit monolithic zirconia bridge. For each patient, in the first group, an impression was made with a two-step putty-wash technique using scannable polyvinyl siloxane material (BONASCAN; DMP, Greece). In the identical session, as the second group, an impression of conventional putty-wash polyvinyl siloxane was taken (BONASIL A(+) Putty; DMP, Greece). The marginal discrepancy was measured through the replicas, which were cut perpendicularly within the buccolingual and mesiodistal directions. An Independent t-test was employed for data analyses (P < 0.05). RESULTS: The marginal discrepancy in a conventional method for central abutment in mid-buccal, mid-lingual, mid-mesial, and mid-distal was higher than in the scannable method but it was not significant (P > 0.05). Also, the marginal discrepancy for canine abutment in the conventional method was higher than in the scannable method, but it was not significant, either (P > 0.05). CONCLUSIONS: FPDs fabricated from both scannable and conventional impression materials were not superior to each other in marginal fit for both central and canine abutments by evaluation using the replica technique.
format Online
Article
Text
id pubmed-9885647
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-98856472023-01-31 Clinical evaluation of marginal fit of uncemented CAD-CAM monolithic zirconia three-unit restorations in anterior areas, using scannable and conventional polyvinyl siloxane impression materials Kalantari, Mohammad Hassan Abbasi, Benika Giti, Rashin Rastegar, Zahra Tavanafar, Saeid Shahsavari-pour, Sheila BMC Oral Health Research BACKGROUND: The accuracy of impression techniques determines the marginal fit of fixed prostheses. Marginal accuracy plays a main role in the success and failure of treatments. This in-vivo study evaluated the marginal fit of anterior three-unit monolithic zirconia fixed partial dentures (FPDs) using conventional and scannable polyvinyl siloxane impression materials. METHODS: Ten patients were selected to replace the lateral teeth with a three-unit monolithic zirconia bridge. For each patient, in the first group, an impression was made with a two-step putty-wash technique using scannable polyvinyl siloxane material (BONASCAN; DMP, Greece). In the identical session, as the second group, an impression of conventional putty-wash polyvinyl siloxane was taken (BONASIL A(+) Putty; DMP, Greece). The marginal discrepancy was measured through the replicas, which were cut perpendicularly within the buccolingual and mesiodistal directions. An Independent t-test was employed for data analyses (P < 0.05). RESULTS: The marginal discrepancy in a conventional method for central abutment in mid-buccal, mid-lingual, mid-mesial, and mid-distal was higher than in the scannable method but it was not significant (P > 0.05). Also, the marginal discrepancy for canine abutment in the conventional method was higher than in the scannable method, but it was not significant, either (P > 0.05). CONCLUSIONS: FPDs fabricated from both scannable and conventional impression materials were not superior to each other in marginal fit for both central and canine abutments by evaluation using the replica technique. BioMed Central 2023-01-30 /pmc/articles/PMC9885647/ /pubmed/36717822 http://dx.doi.org/10.1186/s12903-023-02771-z Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Research
Kalantari, Mohammad Hassan
Abbasi, Benika
Giti, Rashin
Rastegar, Zahra
Tavanafar, Saeid
Shahsavari-pour, Sheila
Clinical evaluation of marginal fit of uncemented CAD-CAM monolithic zirconia three-unit restorations in anterior areas, using scannable and conventional polyvinyl siloxane impression materials
title Clinical evaluation of marginal fit of uncemented CAD-CAM monolithic zirconia three-unit restorations in anterior areas, using scannable and conventional polyvinyl siloxane impression materials
title_full Clinical evaluation of marginal fit of uncemented CAD-CAM monolithic zirconia three-unit restorations in anterior areas, using scannable and conventional polyvinyl siloxane impression materials
title_fullStr Clinical evaluation of marginal fit of uncemented CAD-CAM monolithic zirconia three-unit restorations in anterior areas, using scannable and conventional polyvinyl siloxane impression materials
title_full_unstemmed Clinical evaluation of marginal fit of uncemented CAD-CAM monolithic zirconia three-unit restorations in anterior areas, using scannable and conventional polyvinyl siloxane impression materials
title_short Clinical evaluation of marginal fit of uncemented CAD-CAM monolithic zirconia three-unit restorations in anterior areas, using scannable and conventional polyvinyl siloxane impression materials
title_sort clinical evaluation of marginal fit of uncemented cad-cam monolithic zirconia three-unit restorations in anterior areas, using scannable and conventional polyvinyl siloxane impression materials
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9885647/
https://www.ncbi.nlm.nih.gov/pubmed/36717822
http://dx.doi.org/10.1186/s12903-023-02771-z
work_keys_str_mv AT kalantarimohammadhassan clinicalevaluationofmarginalfitofuncementedcadcammonolithiczirconiathreeunitrestorationsinanteriorareasusingscannableandconventionalpolyvinylsiloxaneimpressionmaterials
AT abbasibenika clinicalevaluationofmarginalfitofuncementedcadcammonolithiczirconiathreeunitrestorationsinanteriorareasusingscannableandconventionalpolyvinylsiloxaneimpressionmaterials
AT gitirashin clinicalevaluationofmarginalfitofuncementedcadcammonolithiczirconiathreeunitrestorationsinanteriorareasusingscannableandconventionalpolyvinylsiloxaneimpressionmaterials
AT rastegarzahra clinicalevaluationofmarginalfitofuncementedcadcammonolithiczirconiathreeunitrestorationsinanteriorareasusingscannableandconventionalpolyvinylsiloxaneimpressionmaterials
AT tavanafarsaeid clinicalevaluationofmarginalfitofuncementedcadcammonolithiczirconiathreeunitrestorationsinanteriorareasusingscannableandconventionalpolyvinylsiloxaneimpressionmaterials
AT shahsavaripoursheila clinicalevaluationofmarginalfitofuncementedcadcammonolithiczirconiathreeunitrestorationsinanteriorareasusingscannableandconventionalpolyvinylsiloxaneimpressionmaterials