Cargando…
Clinical evaluation of marginal fit of uncemented CAD-CAM monolithic zirconia three-unit restorations in anterior areas, using scannable and conventional polyvinyl siloxane impression materials
BACKGROUND: The accuracy of impression techniques determines the marginal fit of fixed prostheses. Marginal accuracy plays a main role in the success and failure of treatments. This in-vivo study evaluated the marginal fit of anterior three-unit monolithic zirconia fixed partial dentures (FPDs) usin...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9885647/ https://www.ncbi.nlm.nih.gov/pubmed/36717822 http://dx.doi.org/10.1186/s12903-023-02771-z |
_version_ | 1784879972186324992 |
---|---|
author | Kalantari, Mohammad Hassan Abbasi, Benika Giti, Rashin Rastegar, Zahra Tavanafar, Saeid Shahsavari-pour, Sheila |
author_facet | Kalantari, Mohammad Hassan Abbasi, Benika Giti, Rashin Rastegar, Zahra Tavanafar, Saeid Shahsavari-pour, Sheila |
author_sort | Kalantari, Mohammad Hassan |
collection | PubMed |
description | BACKGROUND: The accuracy of impression techniques determines the marginal fit of fixed prostheses. Marginal accuracy plays a main role in the success and failure of treatments. This in-vivo study evaluated the marginal fit of anterior three-unit monolithic zirconia fixed partial dentures (FPDs) using conventional and scannable polyvinyl siloxane impression materials. METHODS: Ten patients were selected to replace the lateral teeth with a three-unit monolithic zirconia bridge. For each patient, in the first group, an impression was made with a two-step putty-wash technique using scannable polyvinyl siloxane material (BONASCAN; DMP, Greece). In the identical session, as the second group, an impression of conventional putty-wash polyvinyl siloxane was taken (BONASIL A(+) Putty; DMP, Greece). The marginal discrepancy was measured through the replicas, which were cut perpendicularly within the buccolingual and mesiodistal directions. An Independent t-test was employed for data analyses (P < 0.05). RESULTS: The marginal discrepancy in a conventional method for central abutment in mid-buccal, mid-lingual, mid-mesial, and mid-distal was higher than in the scannable method but it was not significant (P > 0.05). Also, the marginal discrepancy for canine abutment in the conventional method was higher than in the scannable method, but it was not significant, either (P > 0.05). CONCLUSIONS: FPDs fabricated from both scannable and conventional impression materials were not superior to each other in marginal fit for both central and canine abutments by evaluation using the replica technique. |
format | Online Article Text |
id | pubmed-9885647 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-98856472023-01-31 Clinical evaluation of marginal fit of uncemented CAD-CAM monolithic zirconia three-unit restorations in anterior areas, using scannable and conventional polyvinyl siloxane impression materials Kalantari, Mohammad Hassan Abbasi, Benika Giti, Rashin Rastegar, Zahra Tavanafar, Saeid Shahsavari-pour, Sheila BMC Oral Health Research BACKGROUND: The accuracy of impression techniques determines the marginal fit of fixed prostheses. Marginal accuracy plays a main role in the success and failure of treatments. This in-vivo study evaluated the marginal fit of anterior three-unit monolithic zirconia fixed partial dentures (FPDs) using conventional and scannable polyvinyl siloxane impression materials. METHODS: Ten patients were selected to replace the lateral teeth with a three-unit monolithic zirconia bridge. For each patient, in the first group, an impression was made with a two-step putty-wash technique using scannable polyvinyl siloxane material (BONASCAN; DMP, Greece). In the identical session, as the second group, an impression of conventional putty-wash polyvinyl siloxane was taken (BONASIL A(+) Putty; DMP, Greece). The marginal discrepancy was measured through the replicas, which were cut perpendicularly within the buccolingual and mesiodistal directions. An Independent t-test was employed for data analyses (P < 0.05). RESULTS: The marginal discrepancy in a conventional method for central abutment in mid-buccal, mid-lingual, mid-mesial, and mid-distal was higher than in the scannable method but it was not significant (P > 0.05). Also, the marginal discrepancy for canine abutment in the conventional method was higher than in the scannable method, but it was not significant, either (P > 0.05). CONCLUSIONS: FPDs fabricated from both scannable and conventional impression materials were not superior to each other in marginal fit for both central and canine abutments by evaluation using the replica technique. BioMed Central 2023-01-30 /pmc/articles/PMC9885647/ /pubmed/36717822 http://dx.doi.org/10.1186/s12903-023-02771-z Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Research Kalantari, Mohammad Hassan Abbasi, Benika Giti, Rashin Rastegar, Zahra Tavanafar, Saeid Shahsavari-pour, Sheila Clinical evaluation of marginal fit of uncemented CAD-CAM monolithic zirconia three-unit restorations in anterior areas, using scannable and conventional polyvinyl siloxane impression materials |
title | Clinical evaluation of marginal fit of uncemented CAD-CAM monolithic zirconia three-unit restorations in anterior areas, using scannable and conventional polyvinyl siloxane impression materials |
title_full | Clinical evaluation of marginal fit of uncemented CAD-CAM monolithic zirconia three-unit restorations in anterior areas, using scannable and conventional polyvinyl siloxane impression materials |
title_fullStr | Clinical evaluation of marginal fit of uncemented CAD-CAM monolithic zirconia three-unit restorations in anterior areas, using scannable and conventional polyvinyl siloxane impression materials |
title_full_unstemmed | Clinical evaluation of marginal fit of uncemented CAD-CAM monolithic zirconia three-unit restorations in anterior areas, using scannable and conventional polyvinyl siloxane impression materials |
title_short | Clinical evaluation of marginal fit of uncemented CAD-CAM monolithic zirconia three-unit restorations in anterior areas, using scannable and conventional polyvinyl siloxane impression materials |
title_sort | clinical evaluation of marginal fit of uncemented cad-cam monolithic zirconia three-unit restorations in anterior areas, using scannable and conventional polyvinyl siloxane impression materials |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9885647/ https://www.ncbi.nlm.nih.gov/pubmed/36717822 http://dx.doi.org/10.1186/s12903-023-02771-z |
work_keys_str_mv | AT kalantarimohammadhassan clinicalevaluationofmarginalfitofuncementedcadcammonolithiczirconiathreeunitrestorationsinanteriorareasusingscannableandconventionalpolyvinylsiloxaneimpressionmaterials AT abbasibenika clinicalevaluationofmarginalfitofuncementedcadcammonolithiczirconiathreeunitrestorationsinanteriorareasusingscannableandconventionalpolyvinylsiloxaneimpressionmaterials AT gitirashin clinicalevaluationofmarginalfitofuncementedcadcammonolithiczirconiathreeunitrestorationsinanteriorareasusingscannableandconventionalpolyvinylsiloxaneimpressionmaterials AT rastegarzahra clinicalevaluationofmarginalfitofuncementedcadcammonolithiczirconiathreeunitrestorationsinanteriorareasusingscannableandconventionalpolyvinylsiloxaneimpressionmaterials AT tavanafarsaeid clinicalevaluationofmarginalfitofuncementedcadcammonolithiczirconiathreeunitrestorationsinanteriorareasusingscannableandconventionalpolyvinylsiloxaneimpressionmaterials AT shahsavaripoursheila clinicalevaluationofmarginalfitofuncementedcadcammonolithiczirconiathreeunitrestorationsinanteriorareasusingscannableandconventionalpolyvinylsiloxaneimpressionmaterials |