Cargando…

Clinical factors associated with peripherally inserted central catheters (PICC) related bloodstream infections: a single centre retrospective cohort

BACKGROUND: Despite their spread in daily practice, few data is available on clinical factors associated with peripherally inserted central catheter (PICC)-related bloodstream infections (PR-BSI). We aimed to assess the PR-BSI incidence, microbiology, and factors associated with PR-BSI with a focus...

Descripción completa

Detalles Bibliográficos
Autores principales: Barrigah-Benissan, Koko, Ory, Jerome, Simon, Claire, Loubet, Paul, Martin, Aurelie, Beregi, Jean-Paul, Lavigne, Jean-Philippe, Sotto, Albert, Larcher, Romaric
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9885663/
https://www.ncbi.nlm.nih.gov/pubmed/36717942
http://dx.doi.org/10.1186/s13756-023-01209-z
Descripción
Sumario:BACKGROUND: Despite their spread in daily practice, few data is available on clinical factors associated with peripherally inserted central catheter (PICC)-related bloodstream infections (PR-BSI). We aimed to assess the PR-BSI incidence, microbiology, and factors associated with PR-BSI with a focus on clinical symptoms. METHODS: We conducted a retrospective cohort study in a French university hospital. We screened all PICC insertions performed from April 1st, 2018, to April 1st, 2019, and included PICC insertions in adult patients. We assessed the PR-BSI incidence, the factors associated with PR-BSI using a Cox model, and negative and positive predictive values (NPVs and PPVs) of each clinical sign for PR-BSI. RESULTS: Of the 901 PICCs inserted in 783 patients (38,320 catheters days), 214 PICCs (24%) presented with a complication. The most prevalent complication was PR-BSI (1.9 per 1000 catheter days; 8.1% of inserted PICCs ). Enterobacterales (N = 27, 37%) and coagulase negative Staphylococci (N = 24, 33%), were the main microorganisms responsible for PR-BSI. Factors independently associated with occurrence of PR-BSI were fever (hazard ratio 13.21, 95% confidence interval 6.00–29.11, p < 0.001) and chills (HR 3.66, 95%CI 1.92–6.99, p < 0.001). All clinical signs and a duration of PICC maintenance ≥ 28 days, had a low PPVs (≤ 67.1%) but high NPVs (≥ 92.5%) for PR-BSI. CONCLUSIONS: Monitoring of clinical signs, especially fever and chills, with caution and limitation of device maintenance duration, could improve PICC management.