Cargando…
Comparing size measurement of colorectal polyps using a novel virtual scale endoscope, endoscopic ruler or forceps: A preclinical randomized trial
Background and study aims Accurate polyp size measurement is important for guideline conforming choice of polypectomy techniques and subsequent surveillance interval assignments. Some endoscopic tools (biopsy forceps [BF] or endoscopic rulers [ER]) exist to help with visual size estimation. A virtu...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Georg Thieme Verlag KG
2023
|
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9886501/ https://www.ncbi.nlm.nih.gov/pubmed/36726860 http://dx.doi.org/10.1055/a-2005-7548 |
_version_ | 1784880142189854720 |
---|---|
author | Djinbachian, Roupen Taghiakbari, Mahsa Haumesser, Claire Zarandi-Nowroozi, Melissa Khalil, Maria Abou Sidani, Sacha Liu, Jeremy Panzini, Benoit von Renteln, Daniel |
author_facet | Djinbachian, Roupen Taghiakbari, Mahsa Haumesser, Claire Zarandi-Nowroozi, Melissa Khalil, Maria Abou Sidani, Sacha Liu, Jeremy Panzini, Benoit von Renteln, Daniel |
author_sort | Djinbachian, Roupen |
collection | PubMed |
description | Background and study aims Accurate polyp size measurement is important for guideline conforming choice of polypectomy techniques and subsequent surveillance interval assignments. Some endoscopic tools (biopsy forceps [BF] or endoscopic rulers [ER]) exist to help with visual size estimation. A virtual scale endoscope (VSE) has been developed that allows superimposing a virtual measurement scale during live endoscopies. Our aim was to evaluate the performance of VSE when compared to ER and BF-based measurement. Methods We conducted a preclinical randomized trial to evaluate the relative accuracy of size measurement of simulated colorectal polyps when using: VSE, ER, and BF. Six endoscopists performed 60 measurements randomized at a 1:1:1 ratio using each method. Primary outcome was relative accuracy in polyp size measurement. Secondary outcomes included misclassification of sizes at the 5-, 10-, and 20-mm thresholds. Results A total of 360 measurements were performed. The relative accuracy of BF, ER, and VSE was 78.9 % (95 %CI = 76.2–81.5), 78.4 % (95 %CI = 76.0–80.8), and 82.7 % (95 %CI = 80.8–84.8). VSE had significantly higher accuracy compared to BF ( P = 0.02) and ER ( P = 0.006). VSE misclassified a lower percentage of polyps > 5 mm as ≤ 5 mm (9.4 %) compared to BF (15.7 %) and ER (20.9 %). VSE misclassified a lower percentage of ≥ 20 mm polyps as < 20 mm (8.3 %) compared with BF (66.7 %) and ER (75.0 %). Of polyps ≥10mm, 25.6 %, 25.5 %, and 22.5 % were misclassified as <10 mm with ER, BF, and VSE, respectively. Conclusions VSE had significantly higher relative accuracy in measuring polyps compared to ER or BF assisted measurement. VSE improves correct classification of polyps at clinically important size thresholds. |
format | Online Article Text |
id | pubmed-9886501 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Georg Thieme Verlag KG |
record_format | MEDLINE/PubMed |
spelling | pubmed-98865012023-01-31 Comparing size measurement of colorectal polyps using a novel virtual scale endoscope, endoscopic ruler or forceps: A preclinical randomized trial Djinbachian, Roupen Taghiakbari, Mahsa Haumesser, Claire Zarandi-Nowroozi, Melissa Khalil, Maria Abou Sidani, Sacha Liu, Jeremy Panzini, Benoit von Renteln, Daniel Endosc Int Open Background and study aims Accurate polyp size measurement is important for guideline conforming choice of polypectomy techniques and subsequent surveillance interval assignments. Some endoscopic tools (biopsy forceps [BF] or endoscopic rulers [ER]) exist to help with visual size estimation. A virtual scale endoscope (VSE) has been developed that allows superimposing a virtual measurement scale during live endoscopies. Our aim was to evaluate the performance of VSE when compared to ER and BF-based measurement. Methods We conducted a preclinical randomized trial to evaluate the relative accuracy of size measurement of simulated colorectal polyps when using: VSE, ER, and BF. Six endoscopists performed 60 measurements randomized at a 1:1:1 ratio using each method. Primary outcome was relative accuracy in polyp size measurement. Secondary outcomes included misclassification of sizes at the 5-, 10-, and 20-mm thresholds. Results A total of 360 measurements were performed. The relative accuracy of BF, ER, and VSE was 78.9 % (95 %CI = 76.2–81.5), 78.4 % (95 %CI = 76.0–80.8), and 82.7 % (95 %CI = 80.8–84.8). VSE had significantly higher accuracy compared to BF ( P = 0.02) and ER ( P = 0.006). VSE misclassified a lower percentage of polyps > 5 mm as ≤ 5 mm (9.4 %) compared to BF (15.7 %) and ER (20.9 %). VSE misclassified a lower percentage of ≥ 20 mm polyps as < 20 mm (8.3 %) compared with BF (66.7 %) and ER (75.0 %). Of polyps ≥10mm, 25.6 %, 25.5 %, and 22.5 % were misclassified as <10 mm with ER, BF, and VSE, respectively. Conclusions VSE had significantly higher relative accuracy in measuring polyps compared to ER or BF assisted measurement. VSE improves correct classification of polyps at clinically important size thresholds. Georg Thieme Verlag KG 2023-01-30 /pmc/articles/PMC9886501/ /pubmed/36726860 http://dx.doi.org/10.1055/a-2005-7548 Text en The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution-NonDerivative-NonCommercial License, permitting copying and reproduction so long as the original work is given appropriate credit. Contents may not be used for commercial purposes, or adapted, remixed, transformed or built upon. (https://creativecommons.org/licenses/by-nc-nd/4.0/) https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution-NonCommercial-NoDerivatives License, which permits unrestricted reproduction and distribution, for non-commercial purposes only; and use and reproduction, but not distribution, of adapted material for non-commercial purposes only, provided the original work is properly cited. |
spellingShingle | Djinbachian, Roupen Taghiakbari, Mahsa Haumesser, Claire Zarandi-Nowroozi, Melissa Khalil, Maria Abou Sidani, Sacha Liu, Jeremy Panzini, Benoit von Renteln, Daniel Comparing size measurement of colorectal polyps using a novel virtual scale endoscope, endoscopic ruler or forceps: A preclinical randomized trial |
title | Comparing size measurement of colorectal polyps using a novel virtual scale endoscope, endoscopic ruler or forceps: A preclinical randomized trial |
title_full | Comparing size measurement of colorectal polyps using a novel virtual scale endoscope, endoscopic ruler or forceps: A preclinical randomized trial |
title_fullStr | Comparing size measurement of colorectal polyps using a novel virtual scale endoscope, endoscopic ruler or forceps: A preclinical randomized trial |
title_full_unstemmed | Comparing size measurement of colorectal polyps using a novel virtual scale endoscope, endoscopic ruler or forceps: A preclinical randomized trial |
title_short | Comparing size measurement of colorectal polyps using a novel virtual scale endoscope, endoscopic ruler or forceps: A preclinical randomized trial |
title_sort | comparing size measurement of colorectal polyps using a novel virtual scale endoscope, endoscopic ruler or forceps: a preclinical randomized trial |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9886501/ https://www.ncbi.nlm.nih.gov/pubmed/36726860 http://dx.doi.org/10.1055/a-2005-7548 |
work_keys_str_mv | AT djinbachianroupen comparingsizemeasurementofcolorectalpolypsusinganovelvirtualscaleendoscopeendoscopicrulerorforcepsapreclinicalrandomizedtrial AT taghiakbarimahsa comparingsizemeasurementofcolorectalpolypsusinganovelvirtualscaleendoscopeendoscopicrulerorforcepsapreclinicalrandomizedtrial AT haumesserclaire comparingsizemeasurementofcolorectalpolypsusinganovelvirtualscaleendoscopeendoscopicrulerorforcepsapreclinicalrandomizedtrial AT zarandinowroozimelissa comparingsizemeasurementofcolorectalpolypsusinganovelvirtualscaleendoscopeendoscopicrulerorforcepsapreclinicalrandomizedtrial AT khalilmariaabou comparingsizemeasurementofcolorectalpolypsusinganovelvirtualscaleendoscopeendoscopicrulerorforcepsapreclinicalrandomizedtrial AT sidanisacha comparingsizemeasurementofcolorectalpolypsusinganovelvirtualscaleendoscopeendoscopicrulerorforcepsapreclinicalrandomizedtrial AT liujeremy comparingsizemeasurementofcolorectalpolypsusinganovelvirtualscaleendoscopeendoscopicrulerorforcepsapreclinicalrandomizedtrial AT panzinibenoit comparingsizemeasurementofcolorectalpolypsusinganovelvirtualscaleendoscopeendoscopicrulerorforcepsapreclinicalrandomizedtrial AT vonrentelndaniel comparingsizemeasurementofcolorectalpolypsusinganovelvirtualscaleendoscopeendoscopicrulerorforcepsapreclinicalrandomizedtrial |