Cargando…

Three-Dimensional Scapular Border Method for Glenoid Version Measurements

Variations among methods to measure glenoid version have created uncertainty regarding which method provides the most consistent measurements of morphology. Greater deformity may also make accurate depiction of the native morphology more challenging. This study examined 4 current methods (Friedman,...

Descripción completa

Detalles Bibliográficos
Autores principales: Wilder, Lauren, Simon, Peter, Reyes, Justin, Diaz, Miguel, Munassi, Steven, Frankle, Mark A.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Journal of Bone and Joint Surgery, Inc. 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9886516/
https://www.ncbi.nlm.nih.gov/pubmed/36733708
http://dx.doi.org/10.2106/JBJS.OA.22.00105
_version_ 1784880145794859008
author Wilder, Lauren
Simon, Peter
Reyes, Justin
Diaz, Miguel
Munassi, Steven
Frankle, Mark A.
author_facet Wilder, Lauren
Simon, Peter
Reyes, Justin
Diaz, Miguel
Munassi, Steven
Frankle, Mark A.
author_sort Wilder, Lauren
collection PubMed
description Variations among methods to measure glenoid version have created uncertainty regarding which method provides the most consistent measurements of morphology. Greater deformity may also make accurate depiction of the native morphology more challenging. This study examined 4 current methods (Friedman, corrected Friedman, Ganapathi-Iannotti, and Matsumura) and an experimental scapular border-derived coordinate system method, to compare measurement inconsistencies between methods and reference systems and assess the impact of glenoid deformity on measured glenoid version. METHODS: Three-dimensional scapulae were created from computed tomography (CT) scans of 74 shoulders that had undergone arthroplasty (28 A2, 22 B2, 10 B3, and 14 C glenoids) and 34 shoulders that had not undergone arthroplasty. Glenoid version measurements were made in Mimics using the 4 methods. For the experimental method, scapulae were reconstructed, and 3 orthogonal global coordinate planes (GCPs) were derived from the medial and lateral borders. Version was measured as the angle between the sagittal reference plane and an anterior-posterior glenoid vector. The intraclass correlation coefficient (ICC) was calculated for the Friedman and corrected Friedman methods. Inconsistencies were assessed for all methods using the interquartile range, mean and standard deviation, and repeated-measures analysis of variance. Concordance correlation coefficients (CCCs) were calculated to assess agreement among the methods. RESULTS: Scapular plane-based methods (experimental, Friedman, and corrected Friedman) yielded an average version between −10° and −12°, with average measurement differences among these methods of <2°. Vault methods (Ganapathi-Iannotti and Matsumura) overestimated or underestimated version by an average of 5° to 7° compared with scapular plane-based methods, and showed significant differences of >12° when compared with each other. Scapular plane-based methods maintained consistency with increasing deformity. CONCLUSIONS: The other methods of version measurement using the scapular planes as the reference were highly comparable with the corrected Friedman method. However, when the reference plane was the glenoid vault, version measurements were inconsistent with scapular plane-based methods, which is attributed to differences in the reference systems. In surgical planning, the coordinate system utilized will impact version measurements, which can result in variations in the planned surgical solutions. Additionally, as glenoid deformity increases, this variation resulting from the utilization of different coordinate systems is magnified.
format Online
Article
Text
id pubmed-9886516
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Journal of Bone and Joint Surgery, Inc.
record_format MEDLINE/PubMed
spelling pubmed-98865162023-02-01 Three-Dimensional Scapular Border Method for Glenoid Version Measurements Wilder, Lauren Simon, Peter Reyes, Justin Diaz, Miguel Munassi, Steven Frankle, Mark A. JB JS Open Access Scientific Articles Variations among methods to measure glenoid version have created uncertainty regarding which method provides the most consistent measurements of morphology. Greater deformity may also make accurate depiction of the native morphology more challenging. This study examined 4 current methods (Friedman, corrected Friedman, Ganapathi-Iannotti, and Matsumura) and an experimental scapular border-derived coordinate system method, to compare measurement inconsistencies between methods and reference systems and assess the impact of glenoid deformity on measured glenoid version. METHODS: Three-dimensional scapulae were created from computed tomography (CT) scans of 74 shoulders that had undergone arthroplasty (28 A2, 22 B2, 10 B3, and 14 C glenoids) and 34 shoulders that had not undergone arthroplasty. Glenoid version measurements were made in Mimics using the 4 methods. For the experimental method, scapulae were reconstructed, and 3 orthogonal global coordinate planes (GCPs) were derived from the medial and lateral borders. Version was measured as the angle between the sagittal reference plane and an anterior-posterior glenoid vector. The intraclass correlation coefficient (ICC) was calculated for the Friedman and corrected Friedman methods. Inconsistencies were assessed for all methods using the interquartile range, mean and standard deviation, and repeated-measures analysis of variance. Concordance correlation coefficients (CCCs) were calculated to assess agreement among the methods. RESULTS: Scapular plane-based methods (experimental, Friedman, and corrected Friedman) yielded an average version between −10° and −12°, with average measurement differences among these methods of <2°. Vault methods (Ganapathi-Iannotti and Matsumura) overestimated or underestimated version by an average of 5° to 7° compared with scapular plane-based methods, and showed significant differences of >12° when compared with each other. Scapular plane-based methods maintained consistency with increasing deformity. CONCLUSIONS: The other methods of version measurement using the scapular planes as the reference were highly comparable with the corrected Friedman method. However, when the reference plane was the glenoid vault, version measurements were inconsistent with scapular plane-based methods, which is attributed to differences in the reference systems. In surgical planning, the coordinate system utilized will impact version measurements, which can result in variations in the planned surgical solutions. Additionally, as glenoid deformity increases, this variation resulting from the utilization of different coordinate systems is magnified. Journal of Bone and Joint Surgery, Inc. 2023-01-31 /pmc/articles/PMC9886516/ /pubmed/36733708 http://dx.doi.org/10.2106/JBJS.OA.22.00105 Text en Copyright © 2023 The Authors. Published by The Journal of Bone and Joint Surgery, Incorporated. All rights reserved. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article distributed under the terms of the Creative Commons Attribution-Non Commercial-No Derivatives License 4.0 (https://creativecommons.org/licenses/by-nc-nd/4.0/) (CCBY-NC-ND), where it is permissible to download and share the work provided it is properly cited. The work cannot be changed in any way or used commercially without permission from the journal.
spellingShingle Scientific Articles
Wilder, Lauren
Simon, Peter
Reyes, Justin
Diaz, Miguel
Munassi, Steven
Frankle, Mark A.
Three-Dimensional Scapular Border Method for Glenoid Version Measurements
title Three-Dimensional Scapular Border Method for Glenoid Version Measurements
title_full Three-Dimensional Scapular Border Method for Glenoid Version Measurements
title_fullStr Three-Dimensional Scapular Border Method for Glenoid Version Measurements
title_full_unstemmed Three-Dimensional Scapular Border Method for Glenoid Version Measurements
title_short Three-Dimensional Scapular Border Method for Glenoid Version Measurements
title_sort three-dimensional scapular border method for glenoid version measurements
topic Scientific Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9886516/
https://www.ncbi.nlm.nih.gov/pubmed/36733708
http://dx.doi.org/10.2106/JBJS.OA.22.00105
work_keys_str_mv AT wilderlauren threedimensionalscapularbordermethodforglenoidversionmeasurements
AT simonpeter threedimensionalscapularbordermethodforglenoidversionmeasurements
AT reyesjustin threedimensionalscapularbordermethodforglenoidversionmeasurements
AT diazmiguel threedimensionalscapularbordermethodforglenoidversionmeasurements
AT munassisteven threedimensionalscapularbordermethodforglenoidversionmeasurements
AT franklemarka threedimensionalscapularbordermethodforglenoidversionmeasurements