Cargando…
Augmented reality through head-mounted display for navigation of baseplate component placement in reverse total shoulder arthroplasty: a cadaveric study
BACKGROUND: To achieve an optimal clinical outcome in reverse total shoulder arthroplasty (RSA), accurate placement of the components is essential. The recently introduced navigation technology of augmented reality (AR) through head-mounted displays (HMD) offers a promising new approach to visualize...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer Berlin Heidelberg
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9886637/ https://www.ncbi.nlm.nih.gov/pubmed/34213578 http://dx.doi.org/10.1007/s00402-021-04025-5 |
_version_ | 1784880173648183296 |
---|---|
author | Kriechling, Philipp Loucas, Rafael Loucas, Marios Casari, Fabio Fürnstahl, Philipp Wieser, Karl |
author_facet | Kriechling, Philipp Loucas, Rafael Loucas, Marios Casari, Fabio Fürnstahl, Philipp Wieser, Karl |
author_sort | Kriechling, Philipp |
collection | PubMed |
description | BACKGROUND: To achieve an optimal clinical outcome in reverse total shoulder arthroplasty (RSA), accurate placement of the components is essential. The recently introduced navigation technology of augmented reality (AR) through head-mounted displays (HMD) offers a promising new approach to visualize the anatomy and navigate component positioning in various orthopedic surgeries. We hypothesized that AR through HMD is feasible, reliable, and accurate for guidewire placement in RSA baseplate positioning. METHODS: Twelve human cadaver shoulders were scanned with computed tomography (CT) and RSA baseplate positioning was 3-D planned using dedicated software. The shoulders were prepared through a deltopectoral approach and an augmented reality hologram was superimposed using the HMD Microsoft HoloLense. The central guidewire was then navigated through the HMD to achieve the planned entry point and trajectory. Postoperatively, the shoulders were CT-scanned a second time and the deviation from the planning was calculated. RESULTS: The mean deviation of the entry point was 3.5 mm ± 1.7 mm (95% CI 2.4 mm; 4.6 mm). The mean deviation of the planned trajectory was 3.8° ± 1.7° (95% CI 2.6°; 4.9°). CONCLUSION: Augmented reality seems feasible and reliable for baseplate guidewire positioning in reverse total shoulder arthroplasty. The achieved values were accurate. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s00402-021-04025-5. |
format | Online Article Text |
id | pubmed-9886637 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Springer Berlin Heidelberg |
record_format | MEDLINE/PubMed |
spelling | pubmed-98866372023-02-01 Augmented reality through head-mounted display for navigation of baseplate component placement in reverse total shoulder arthroplasty: a cadaveric study Kriechling, Philipp Loucas, Rafael Loucas, Marios Casari, Fabio Fürnstahl, Philipp Wieser, Karl Arch Orthop Trauma Surg Orthopaedic Surgery BACKGROUND: To achieve an optimal clinical outcome in reverse total shoulder arthroplasty (RSA), accurate placement of the components is essential. The recently introduced navigation technology of augmented reality (AR) through head-mounted displays (HMD) offers a promising new approach to visualize the anatomy and navigate component positioning in various orthopedic surgeries. We hypothesized that AR through HMD is feasible, reliable, and accurate for guidewire placement in RSA baseplate positioning. METHODS: Twelve human cadaver shoulders were scanned with computed tomography (CT) and RSA baseplate positioning was 3-D planned using dedicated software. The shoulders were prepared through a deltopectoral approach and an augmented reality hologram was superimposed using the HMD Microsoft HoloLense. The central guidewire was then navigated through the HMD to achieve the planned entry point and trajectory. Postoperatively, the shoulders were CT-scanned a second time and the deviation from the planning was calculated. RESULTS: The mean deviation of the entry point was 3.5 mm ± 1.7 mm (95% CI 2.4 mm; 4.6 mm). The mean deviation of the planned trajectory was 3.8° ± 1.7° (95% CI 2.6°; 4.9°). CONCLUSION: Augmented reality seems feasible and reliable for baseplate guidewire positioning in reverse total shoulder arthroplasty. The achieved values were accurate. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s00402-021-04025-5. Springer Berlin Heidelberg 2021-07-02 2023 /pmc/articles/PMC9886637/ /pubmed/34213578 http://dx.doi.org/10.1007/s00402-021-04025-5 Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . |
spellingShingle | Orthopaedic Surgery Kriechling, Philipp Loucas, Rafael Loucas, Marios Casari, Fabio Fürnstahl, Philipp Wieser, Karl Augmented reality through head-mounted display for navigation of baseplate component placement in reverse total shoulder arthroplasty: a cadaveric study |
title | Augmented reality through head-mounted display for navigation of baseplate component placement in reverse total shoulder arthroplasty: a cadaveric study |
title_full | Augmented reality through head-mounted display for navigation of baseplate component placement in reverse total shoulder arthroplasty: a cadaveric study |
title_fullStr | Augmented reality through head-mounted display for navigation of baseplate component placement in reverse total shoulder arthroplasty: a cadaveric study |
title_full_unstemmed | Augmented reality through head-mounted display for navigation of baseplate component placement in reverse total shoulder arthroplasty: a cadaveric study |
title_short | Augmented reality through head-mounted display for navigation of baseplate component placement in reverse total shoulder arthroplasty: a cadaveric study |
title_sort | augmented reality through head-mounted display for navigation of baseplate component placement in reverse total shoulder arthroplasty: a cadaveric study |
topic | Orthopaedic Surgery |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9886637/ https://www.ncbi.nlm.nih.gov/pubmed/34213578 http://dx.doi.org/10.1007/s00402-021-04025-5 |
work_keys_str_mv | AT kriechlingphilipp augmentedrealitythroughheadmounteddisplayfornavigationofbaseplatecomponentplacementinreversetotalshoulderarthroplastyacadavericstudy AT loucasrafael augmentedrealitythroughheadmounteddisplayfornavigationofbaseplatecomponentplacementinreversetotalshoulderarthroplastyacadavericstudy AT loucasmarios augmentedrealitythroughheadmounteddisplayfornavigationofbaseplatecomponentplacementinreversetotalshoulderarthroplastyacadavericstudy AT casarifabio augmentedrealitythroughheadmounteddisplayfornavigationofbaseplatecomponentplacementinreversetotalshoulderarthroplastyacadavericstudy AT furnstahlphilipp augmentedrealitythroughheadmounteddisplayfornavigationofbaseplatecomponentplacementinreversetotalshoulderarthroplastyacadavericstudy AT wieserkarl augmentedrealitythroughheadmounteddisplayfornavigationofbaseplatecomponentplacementinreversetotalshoulderarthroplastyacadavericstudy |