Cargando…
Smartphone-based cardiac implantable electronic device remote monitoring: improved compliance and connectivity
AIMS: Remote monitoring (RM) is the standard of care for follow up of patients with cardiac implantable electronic devices. The aim of this study was to compare smartphone-based RM (SM-RM) using patient applications (myMerlinPulse™ app) with traditional bedside monitor RM (BM-RM). METHODS AND RESULT...
Autores principales: | , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Oxford University Press
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9890086/ https://www.ncbi.nlm.nih.gov/pubmed/36743871 http://dx.doi.org/10.1093/ehjdh/ztac071 |
_version_ | 1784880878657208320 |
---|---|
author | Manyam, Harish Burri, Haran Casado-Arroyo, Ruben Varma, Niraj Lennerz, Carsten Klug, Didier Carr-White, Gerald Kolli, Kranthi Reyes, Ignacio Nabutovsky, Yelena Boriani, Giuseppe |
author_facet | Manyam, Harish Burri, Haran Casado-Arroyo, Ruben Varma, Niraj Lennerz, Carsten Klug, Didier Carr-White, Gerald Kolli, Kranthi Reyes, Ignacio Nabutovsky, Yelena Boriani, Giuseppe |
author_sort | Manyam, Harish |
collection | PubMed |
description | AIMS: Remote monitoring (RM) is the standard of care for follow up of patients with cardiac implantable electronic devices. The aim of this study was to compare smartphone-based RM (SM-RM) using patient applications (myMerlinPulse™ app) with traditional bedside monitor RM (BM-RM). METHODS AND RESULTS: The retrospective study included de-identified US patients who received either SM-RM or BM-RM capable of implantable cardioverter defibrillators or cardiac resynchronization therapy defibrillators (Abbott, USA). Patients in SM-RM and BM-RM groups were propensity-score matched on age and gender, device type, implant year, and month. Compliance with RM was quantified as the proportion of patients enrolling in the RM system (Merlin.net™) and transmitting data at least once. Connectivity was measured by the median number of days between consecutive transmissions per patient. Of the initial 9714 patients with SM-RM and 26 679 patients with BM-RM, 9397 patients from each group were matched. Remote monitoring compliance was higher in SM-RM; significantly more patients with SM-RM were enrolled in RM compared with BM-RM (94.4 vs. 85.0%, P < 0.001), similar number of patients in the SM-RM group paired their device (95.1 vs. 95.0%, P = 0.77), but more SM-RM patients transmitted at least once (98.1 vs. 94.3%, P < 0.001). Connectivity was significantly higher in the SM-RM, with patients transmitting data every 1.2 (1.1, 1.7) vs. every 1.7 (1.5, 2.0) days with BM-RM (P < 0.001) and remained better over time. Significantly more SM-RM patients utilized patient-initiated transmissions compared with BM-RM (55.6 vs. 28.1%, P < 0.001). CONCLUSION: In this large real-world study, patients with SM-RM demonstrated improved compliance and connectivity compared with BM-RM. |
format | Online Article Text |
id | pubmed-9890086 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Oxford University Press |
record_format | MEDLINE/PubMed |
spelling | pubmed-98900862023-02-02 Smartphone-based cardiac implantable electronic device remote monitoring: improved compliance and connectivity Manyam, Harish Burri, Haran Casado-Arroyo, Ruben Varma, Niraj Lennerz, Carsten Klug, Didier Carr-White, Gerald Kolli, Kranthi Reyes, Ignacio Nabutovsky, Yelena Boriani, Giuseppe Eur Heart J Digit Health Original Article AIMS: Remote monitoring (RM) is the standard of care for follow up of patients with cardiac implantable electronic devices. The aim of this study was to compare smartphone-based RM (SM-RM) using patient applications (myMerlinPulse™ app) with traditional bedside monitor RM (BM-RM). METHODS AND RESULTS: The retrospective study included de-identified US patients who received either SM-RM or BM-RM capable of implantable cardioverter defibrillators or cardiac resynchronization therapy defibrillators (Abbott, USA). Patients in SM-RM and BM-RM groups were propensity-score matched on age and gender, device type, implant year, and month. Compliance with RM was quantified as the proportion of patients enrolling in the RM system (Merlin.net™) and transmitting data at least once. Connectivity was measured by the median number of days between consecutive transmissions per patient. Of the initial 9714 patients with SM-RM and 26 679 patients with BM-RM, 9397 patients from each group were matched. Remote monitoring compliance was higher in SM-RM; significantly more patients with SM-RM were enrolled in RM compared with BM-RM (94.4 vs. 85.0%, P < 0.001), similar number of patients in the SM-RM group paired their device (95.1 vs. 95.0%, P = 0.77), but more SM-RM patients transmitted at least once (98.1 vs. 94.3%, P < 0.001). Connectivity was significantly higher in the SM-RM, with patients transmitting data every 1.2 (1.1, 1.7) vs. every 1.7 (1.5, 2.0) days with BM-RM (P < 0.001) and remained better over time. Significantly more SM-RM patients utilized patient-initiated transmissions compared with BM-RM (55.6 vs. 28.1%, P < 0.001). CONCLUSION: In this large real-world study, patients with SM-RM demonstrated improved compliance and connectivity compared with BM-RM. Oxford University Press 2022-11-11 /pmc/articles/PMC9890086/ /pubmed/36743871 http://dx.doi.org/10.1093/ehjdh/ztac071 Text en © The Author(s) 2022. Published by Oxford University Press on behalf of the European Society of Cardiology. https://creativecommons.org/licenses/by-nc/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution-NonCommercial License (https://creativecommons.org/licenses/by-nc/4.0/), which permits non-commercial re-use, distribution, and reproduction in any medium, provided the original work is properly cited. For commercial re-use, please contact journals.permissions@oup.com |
spellingShingle | Original Article Manyam, Harish Burri, Haran Casado-Arroyo, Ruben Varma, Niraj Lennerz, Carsten Klug, Didier Carr-White, Gerald Kolli, Kranthi Reyes, Ignacio Nabutovsky, Yelena Boriani, Giuseppe Smartphone-based cardiac implantable electronic device remote monitoring: improved compliance and connectivity |
title | Smartphone-based cardiac implantable electronic device remote monitoring: improved compliance and connectivity |
title_full | Smartphone-based cardiac implantable electronic device remote monitoring: improved compliance and connectivity |
title_fullStr | Smartphone-based cardiac implantable electronic device remote monitoring: improved compliance and connectivity |
title_full_unstemmed | Smartphone-based cardiac implantable electronic device remote monitoring: improved compliance and connectivity |
title_short | Smartphone-based cardiac implantable electronic device remote monitoring: improved compliance and connectivity |
title_sort | smartphone-based cardiac implantable electronic device remote monitoring: improved compliance and connectivity |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9890086/ https://www.ncbi.nlm.nih.gov/pubmed/36743871 http://dx.doi.org/10.1093/ehjdh/ztac071 |
work_keys_str_mv | AT manyamharish smartphonebasedcardiacimplantableelectronicdeviceremotemonitoringimprovedcomplianceandconnectivity AT burriharan smartphonebasedcardiacimplantableelectronicdeviceremotemonitoringimprovedcomplianceandconnectivity AT casadoarroyoruben smartphonebasedcardiacimplantableelectronicdeviceremotemonitoringimprovedcomplianceandconnectivity AT varmaniraj smartphonebasedcardiacimplantableelectronicdeviceremotemonitoringimprovedcomplianceandconnectivity AT lennerzcarsten smartphonebasedcardiacimplantableelectronicdeviceremotemonitoringimprovedcomplianceandconnectivity AT klugdidier smartphonebasedcardiacimplantableelectronicdeviceremotemonitoringimprovedcomplianceandconnectivity AT carrwhitegerald smartphonebasedcardiacimplantableelectronicdeviceremotemonitoringimprovedcomplianceandconnectivity AT kollikranthi smartphonebasedcardiacimplantableelectronicdeviceremotemonitoringimprovedcomplianceandconnectivity AT reyesignacio smartphonebasedcardiacimplantableelectronicdeviceremotemonitoringimprovedcomplianceandconnectivity AT nabutovskyyelena smartphonebasedcardiacimplantableelectronicdeviceremotemonitoringimprovedcomplianceandconnectivity AT borianigiuseppe smartphonebasedcardiacimplantableelectronicdeviceremotemonitoringimprovedcomplianceandconnectivity |