Cargando…

Comparison of dynamic defocus curve on cataract patients implanting extended depth of focus and monofocal intraocular lens

BACKGROUND: The aim of the study was to compare the dynamic defocus curve on patients post-implantation of the extended depth-of-focus (EDOF) and monofocal intraocular lens (IOL). METHODS: A total of 62 age-related cataract patients receiving phacoemulsification with implantation of TECNIS Symfony (...

Descripción completa

Detalles Bibliográficos
Autores principales: Wu, Tingyi, Wang, Yuexin, Yu, Jiazhi, Ren, Xiaotong, Li, Yuanting, Qiu, Weiqiang, Li, Xuemin
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9890684/
https://www.ncbi.nlm.nih.gov/pubmed/36721199
http://dx.doi.org/10.1186/s40662-022-00323-0
_version_ 1784880989002006528
author Wu, Tingyi
Wang, Yuexin
Yu, Jiazhi
Ren, Xiaotong
Li, Yuanting
Qiu, Weiqiang
Li, Xuemin
author_facet Wu, Tingyi
Wang, Yuexin
Yu, Jiazhi
Ren, Xiaotong
Li, Yuanting
Qiu, Weiqiang
Li, Xuemin
author_sort Wu, Tingyi
collection PubMed
description BACKGROUND: The aim of the study was to compare the dynamic defocus curve on patients post-implantation of the extended depth-of-focus (EDOF) and monofocal intraocular lens (IOL). METHODS: A total of 62 age-related cataract patients receiving phacoemulsification with implantation of TECNIS Symfony (ZXR00) or monofocal IOLs were enrolled. The binocular static and dynamic defocus curves with corrected distance visual acuity were evaluated at one month postoperatively. RESULTS: The ZXR00 group achieved significantly better intermediate (P = 0.044) and near (P = 0.017) visual acuity (VA) than the monofocal group. Two groups had similar uncorrected and corrected distance VA (P > 0.05, respectively). The dynamic defocus curve revealed a smoother decline from 0.0 D to − 2.0 D in the ZXR00 group. Defocused dynamic VA in the ZXR00 group was significantly better (P < 0.05) except at 0.0 D (P = 0.724) and − 0.5 D (P = 0.176). The area under the curve (P = 0.002) and corrected dynamic vision accommodation (P = 0.001) derived from the dynamic defocus curves were better in the ZXR00 group. A positive correlation was observed between defocused dynamic and static VA in both groups (P < 0.001). Multiple linear regression analysis indicated that defocused static VA and corrected dynamic vision accommodation were significant influential factors for the defocused dynamic VA from − 1.0 D to − 3.0 D (P < 0.05). CONCLUSIONS: The EDOF IOL provided similar distance vision, better intermediate and near vision, and a better overall dynamic defocus curve than the monofocal IOL. The dynamic defocus curve may be comprehensively applied to evaluate the all-distance dynamic visual performance post-cataract surgery. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s40662-022-00323-0.
format Online
Article
Text
id pubmed-9890684
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-98906842023-02-02 Comparison of dynamic defocus curve on cataract patients implanting extended depth of focus and monofocal intraocular lens Wu, Tingyi Wang, Yuexin Yu, Jiazhi Ren, Xiaotong Li, Yuanting Qiu, Weiqiang Li, Xuemin Eye Vis (Lond) Research BACKGROUND: The aim of the study was to compare the dynamic defocus curve on patients post-implantation of the extended depth-of-focus (EDOF) and monofocal intraocular lens (IOL). METHODS: A total of 62 age-related cataract patients receiving phacoemulsification with implantation of TECNIS Symfony (ZXR00) or monofocal IOLs were enrolled. The binocular static and dynamic defocus curves with corrected distance visual acuity were evaluated at one month postoperatively. RESULTS: The ZXR00 group achieved significantly better intermediate (P = 0.044) and near (P = 0.017) visual acuity (VA) than the monofocal group. Two groups had similar uncorrected and corrected distance VA (P > 0.05, respectively). The dynamic defocus curve revealed a smoother decline from 0.0 D to − 2.0 D in the ZXR00 group. Defocused dynamic VA in the ZXR00 group was significantly better (P < 0.05) except at 0.0 D (P = 0.724) and − 0.5 D (P = 0.176). The area under the curve (P = 0.002) and corrected dynamic vision accommodation (P = 0.001) derived from the dynamic defocus curves were better in the ZXR00 group. A positive correlation was observed between defocused dynamic and static VA in both groups (P < 0.001). Multiple linear regression analysis indicated that defocused static VA and corrected dynamic vision accommodation were significant influential factors for the defocused dynamic VA from − 1.0 D to − 3.0 D (P < 0.05). CONCLUSIONS: The EDOF IOL provided similar distance vision, better intermediate and near vision, and a better overall dynamic defocus curve than the monofocal IOL. The dynamic defocus curve may be comprehensively applied to evaluate the all-distance dynamic visual performance post-cataract surgery. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s40662-022-00323-0. BioMed Central 2023-02-01 /pmc/articles/PMC9890684/ /pubmed/36721199 http://dx.doi.org/10.1186/s40662-022-00323-0 Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Research
Wu, Tingyi
Wang, Yuexin
Yu, Jiazhi
Ren, Xiaotong
Li, Yuanting
Qiu, Weiqiang
Li, Xuemin
Comparison of dynamic defocus curve on cataract patients implanting extended depth of focus and monofocal intraocular lens
title Comparison of dynamic defocus curve on cataract patients implanting extended depth of focus and monofocal intraocular lens
title_full Comparison of dynamic defocus curve on cataract patients implanting extended depth of focus and monofocal intraocular lens
title_fullStr Comparison of dynamic defocus curve on cataract patients implanting extended depth of focus and monofocal intraocular lens
title_full_unstemmed Comparison of dynamic defocus curve on cataract patients implanting extended depth of focus and monofocal intraocular lens
title_short Comparison of dynamic defocus curve on cataract patients implanting extended depth of focus and monofocal intraocular lens
title_sort comparison of dynamic defocus curve on cataract patients implanting extended depth of focus and monofocal intraocular lens
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9890684/
https://www.ncbi.nlm.nih.gov/pubmed/36721199
http://dx.doi.org/10.1186/s40662-022-00323-0
work_keys_str_mv AT wutingyi comparisonofdynamicdefocuscurveoncataractpatientsimplantingextendeddepthoffocusandmonofocalintraocularlens
AT wangyuexin comparisonofdynamicdefocuscurveoncataractpatientsimplantingextendeddepthoffocusandmonofocalintraocularlens
AT yujiazhi comparisonofdynamicdefocuscurveoncataractpatientsimplantingextendeddepthoffocusandmonofocalintraocularlens
AT renxiaotong comparisonofdynamicdefocuscurveoncataractpatientsimplantingextendeddepthoffocusandmonofocalintraocularlens
AT liyuanting comparisonofdynamicdefocuscurveoncataractpatientsimplantingextendeddepthoffocusandmonofocalintraocularlens
AT qiuweiqiang comparisonofdynamicdefocuscurveoncataractpatientsimplantingextendeddepthoffocusandmonofocalintraocularlens
AT lixuemin comparisonofdynamicdefocuscurveoncataractpatientsimplantingextendeddepthoffocusandmonofocalintraocularlens