Cargando…

Influence of the deviated center of rotation on the range of motion after cervical disc arthroplasty –an in vivo study with a minimum of 10-year follow-up

BACKGROUND: Short-term researches have studied the change of the center of rotation (COR) after the Bryan Cervical disc arthroplasty (CDA). But there is a lack of long-term studies focusing on the location of COR and its influence after surgery. METHODS: Clinical and radiographic materials of patien...

Descripción completa

Detalles Bibliográficos
Autores principales: Yan, Kai, Shi, Zhan, He, Da, Liu, Bo, Xiao, Bin, Wang, Qilong, Tian, Wei
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9890835/
https://www.ncbi.nlm.nih.gov/pubmed/36726119
http://dx.doi.org/10.1186/s12891-022-06041-x
_version_ 1784881020508569600
author Yan, Kai
Shi, Zhan
He, Da
Liu, Bo
Xiao, Bin
Wang, Qilong
Tian, Wei
author_facet Yan, Kai
Shi, Zhan
He, Da
Liu, Bo
Xiao, Bin
Wang, Qilong
Tian, Wei
author_sort Yan, Kai
collection PubMed
description BACKGROUND: Short-term researches have studied the change of the center of rotation (COR) after the Bryan Cervical disc arthroplasty (CDA). But there is a lack of long-term studies focusing on the location of COR and its influence after surgery. METHODS: Clinical and radiographic materials of patients who received CDA were retrospectively reviewed. Written informed consents were obtained. Clinical outcome was accessed by Japanese Orthopaedic Association (JOA), Neck Disability Index (NDI), and Odom’s scale. Radiographic evaluation underwent before surgery, at early (3 months) follow-up and final (minimal 10 years) follow-up. The ROM of the global cervical spine and index level, the functional spine unit (FSU) angle and C2-C7 angle were measured. COR was identified and its coordinates were calculated. The absolute change of COR-x and COR-y were compared in subgroup analysis. RESULTS: Sixty patients were included, with an average age of 55.9 ± 8.1 years old. The mean duration of follow up was 135.1 ± 16.1 (120–155) months. JOA, NDI and Odom’s scale showed significant improvements at 10 years after surgery. The COR of index level was located in the posterior superior half of the caudal vertebral body. Following the implant of Bryan Disc, the COR shifted forward and downward. During the 10-year follow-up, the location of COR remained stable. ROM at the index level decreased from 10.6 ± 4.0° preoperatively to 9.3 ± 4.0° at the early follow-up (p = 0.03). The ROM at the index level remained unchanged from early follow-up to the final follow-up (9.3 ± 4.0° vs 9.5 ± 5.2°, p = 0.80). In subgroup analysis, larger changes of both COR-x and COR-y were related with decreased ROM. CONCLUSIONS: Our study illustrated that Bryan CDA could achieved favorable clinical and radiographic outcome over a minimal 10-year follow-up. The reduction of the flexion-extension ROM may be correlated with a more deviated postoperative COR. More attention should be paid to preoperative design and intraoperative technique to obtain a more native COR.
format Online
Article
Text
id pubmed-9890835
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-98908352023-02-02 Influence of the deviated center of rotation on the range of motion after cervical disc arthroplasty –an in vivo study with a minimum of 10-year follow-up Yan, Kai Shi, Zhan He, Da Liu, Bo Xiao, Bin Wang, Qilong Tian, Wei BMC Musculoskelet Disord Research BACKGROUND: Short-term researches have studied the change of the center of rotation (COR) after the Bryan Cervical disc arthroplasty (CDA). But there is a lack of long-term studies focusing on the location of COR and its influence after surgery. METHODS: Clinical and radiographic materials of patients who received CDA were retrospectively reviewed. Written informed consents were obtained. Clinical outcome was accessed by Japanese Orthopaedic Association (JOA), Neck Disability Index (NDI), and Odom’s scale. Radiographic evaluation underwent before surgery, at early (3 months) follow-up and final (minimal 10 years) follow-up. The ROM of the global cervical spine and index level, the functional spine unit (FSU) angle and C2-C7 angle were measured. COR was identified and its coordinates were calculated. The absolute change of COR-x and COR-y were compared in subgroup analysis. RESULTS: Sixty patients were included, with an average age of 55.9 ± 8.1 years old. The mean duration of follow up was 135.1 ± 16.1 (120–155) months. JOA, NDI and Odom’s scale showed significant improvements at 10 years after surgery. The COR of index level was located in the posterior superior half of the caudal vertebral body. Following the implant of Bryan Disc, the COR shifted forward and downward. During the 10-year follow-up, the location of COR remained stable. ROM at the index level decreased from 10.6 ± 4.0° preoperatively to 9.3 ± 4.0° at the early follow-up (p = 0.03). The ROM at the index level remained unchanged from early follow-up to the final follow-up (9.3 ± 4.0° vs 9.5 ± 5.2°, p = 0.80). In subgroup analysis, larger changes of both COR-x and COR-y were related with decreased ROM. CONCLUSIONS: Our study illustrated that Bryan CDA could achieved favorable clinical and radiographic outcome over a minimal 10-year follow-up. The reduction of the flexion-extension ROM may be correlated with a more deviated postoperative COR. More attention should be paid to preoperative design and intraoperative technique to obtain a more native COR. BioMed Central 2023-02-01 /pmc/articles/PMC9890835/ /pubmed/36726119 http://dx.doi.org/10.1186/s12891-022-06041-x Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Research
Yan, Kai
Shi, Zhan
He, Da
Liu, Bo
Xiao, Bin
Wang, Qilong
Tian, Wei
Influence of the deviated center of rotation on the range of motion after cervical disc arthroplasty –an in vivo study with a minimum of 10-year follow-up
title Influence of the deviated center of rotation on the range of motion after cervical disc arthroplasty –an in vivo study with a minimum of 10-year follow-up
title_full Influence of the deviated center of rotation on the range of motion after cervical disc arthroplasty –an in vivo study with a minimum of 10-year follow-up
title_fullStr Influence of the deviated center of rotation on the range of motion after cervical disc arthroplasty –an in vivo study with a minimum of 10-year follow-up
title_full_unstemmed Influence of the deviated center of rotation on the range of motion after cervical disc arthroplasty –an in vivo study with a minimum of 10-year follow-up
title_short Influence of the deviated center of rotation on the range of motion after cervical disc arthroplasty –an in vivo study with a minimum of 10-year follow-up
title_sort influence of the deviated center of rotation on the range of motion after cervical disc arthroplasty –an in vivo study with a minimum of 10-year follow-up
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9890835/
https://www.ncbi.nlm.nih.gov/pubmed/36726119
http://dx.doi.org/10.1186/s12891-022-06041-x
work_keys_str_mv AT yankai influenceofthedeviatedcenterofrotationontherangeofmotionaftercervicaldiscarthroplastyaninvivostudywithaminimumof10yearfollowup
AT shizhan influenceofthedeviatedcenterofrotationontherangeofmotionaftercervicaldiscarthroplastyaninvivostudywithaminimumof10yearfollowup
AT heda influenceofthedeviatedcenterofrotationontherangeofmotionaftercervicaldiscarthroplastyaninvivostudywithaminimumof10yearfollowup
AT liubo influenceofthedeviatedcenterofrotationontherangeofmotionaftercervicaldiscarthroplastyaninvivostudywithaminimumof10yearfollowup
AT xiaobin influenceofthedeviatedcenterofrotationontherangeofmotionaftercervicaldiscarthroplastyaninvivostudywithaminimumof10yearfollowup
AT wangqilong influenceofthedeviatedcenterofrotationontherangeofmotionaftercervicaldiscarthroplastyaninvivostudywithaminimumof10yearfollowup
AT tianwei influenceofthedeviatedcenterofrotationontherangeofmotionaftercervicaldiscarthroplastyaninvivostudywithaminimumof10yearfollowup