Cargando…

Improving total body irradiation with a dedicated couch and 3D-printed patient-specific lung blocks: A feasibility study

INTRODUCTION: Total body irradiation (TBI) is an important component of the conditioning regimen in patients undergoing hematopoietic stem cell transplants. TBI is used in very few patients and therefore it is generally delivered with standard linear accelerators (LINACs) and not with dedicated devi...

Descripción completa

Detalles Bibliográficos
Autores principales: Strolin, Silvia, Paolani, Giulia, Santoro, Miriam, Cercenelli, Laura, Bortolani, Barbara, Ammendolia, Ilario, Cammelli, Silvia, Cicoria, Gianfranco, Win, Phyo Wai, Morganti, Alessio G., Marcelli, Emanuela, Strigari, Lidia
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9893493/
https://www.ncbi.nlm.nih.gov/pubmed/36741733
http://dx.doi.org/10.3389/fonc.2022.1046168
_version_ 1784881539405840384
author Strolin, Silvia
Paolani, Giulia
Santoro, Miriam
Cercenelli, Laura
Bortolani, Barbara
Ammendolia, Ilario
Cammelli, Silvia
Cicoria, Gianfranco
Win, Phyo Wai
Morganti, Alessio G.
Marcelli, Emanuela
Strigari, Lidia
author_facet Strolin, Silvia
Paolani, Giulia
Santoro, Miriam
Cercenelli, Laura
Bortolani, Barbara
Ammendolia, Ilario
Cammelli, Silvia
Cicoria, Gianfranco
Win, Phyo Wai
Morganti, Alessio G.
Marcelli, Emanuela
Strigari, Lidia
author_sort Strolin, Silvia
collection PubMed
description INTRODUCTION: Total body irradiation (TBI) is an important component of the conditioning regimen in patients undergoing hematopoietic stem cell transplants. TBI is used in very few patients and therefore it is generally delivered with standard linear accelerators (LINACs) and not with dedicated devices. Severe pulmonary toxicity is the most common adverse effect after TBI, and patient-specific lead blocks are used to reduce mean lung dose. In this context, online treatment setup is crucial to achieve precise positioning of the lung blocks. Therefore, in this study we aim to report our experience at generating 3D-printed patient-specific lung blocks and coupling a dedicated couch (with an integrated onboard image device) with a modern LINAC for TBI treatment. MATERIAL AND METHODS: TBI was planned and delivered (2Gy/fraction given twice a day, over 3 days) to 15 patients. Online images, to be compared with planned digitally reconstructed radiographies, were acquired with the couch-dedicated Electronic Portal Imaging Device (EPID) panel and imported in the iView software using a homemade Graphical User Interface (GUI). In vivo dosimetry, using Metal-Oxide Field-Effect Transistors (MOSFETs), was used to assess the setup reproducibility in both supine and prone positions. RESULTS: 3D printing of lung blocks was feasible for all planned patients using a stereolithography 3D printer with a build volume of 14.5×14.5×17.5 cm(3). The number of required pre-TBI EPID-images generally decreases after the first fraction. In patient-specific quality assurance, the difference between measured and calculated dose was generally<2%. The MOSFET measurements reproducibility along each treatment and patient was 2.7%, in average. CONCLUSION: The TBI technique was successfully implemented, demonstrating that our approach is feasible, flexible, and cost-effective. The use of 3D-printed patient-specific lung blocks have the potential to personalize TBI treatment and to refine the shape of the blocks before delivery, making them extremely versatile.
format Online
Article
Text
id pubmed-9893493
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-98934932023-02-03 Improving total body irradiation with a dedicated couch and 3D-printed patient-specific lung blocks: A feasibility study Strolin, Silvia Paolani, Giulia Santoro, Miriam Cercenelli, Laura Bortolani, Barbara Ammendolia, Ilario Cammelli, Silvia Cicoria, Gianfranco Win, Phyo Wai Morganti, Alessio G. Marcelli, Emanuela Strigari, Lidia Front Oncol Oncology INTRODUCTION: Total body irradiation (TBI) is an important component of the conditioning regimen in patients undergoing hematopoietic stem cell transplants. TBI is used in very few patients and therefore it is generally delivered with standard linear accelerators (LINACs) and not with dedicated devices. Severe pulmonary toxicity is the most common adverse effect after TBI, and patient-specific lead blocks are used to reduce mean lung dose. In this context, online treatment setup is crucial to achieve precise positioning of the lung blocks. Therefore, in this study we aim to report our experience at generating 3D-printed patient-specific lung blocks and coupling a dedicated couch (with an integrated onboard image device) with a modern LINAC for TBI treatment. MATERIAL AND METHODS: TBI was planned and delivered (2Gy/fraction given twice a day, over 3 days) to 15 patients. Online images, to be compared with planned digitally reconstructed radiographies, were acquired with the couch-dedicated Electronic Portal Imaging Device (EPID) panel and imported in the iView software using a homemade Graphical User Interface (GUI). In vivo dosimetry, using Metal-Oxide Field-Effect Transistors (MOSFETs), was used to assess the setup reproducibility in both supine and prone positions. RESULTS: 3D printing of lung blocks was feasible for all planned patients using a stereolithography 3D printer with a build volume of 14.5×14.5×17.5 cm(3). The number of required pre-TBI EPID-images generally decreases after the first fraction. In patient-specific quality assurance, the difference between measured and calculated dose was generally<2%. The MOSFET measurements reproducibility along each treatment and patient was 2.7%, in average. CONCLUSION: The TBI technique was successfully implemented, demonstrating that our approach is feasible, flexible, and cost-effective. The use of 3D-printed patient-specific lung blocks have the potential to personalize TBI treatment and to refine the shape of the blocks before delivery, making them extremely versatile. Frontiers Media S.A. 2023-01-19 /pmc/articles/PMC9893493/ /pubmed/36741733 http://dx.doi.org/10.3389/fonc.2022.1046168 Text en Copyright © 2023 Strolin, Paolani, Santoro, Cercenelli, Bortolani, Ammendolia, Cammelli, Cicoria, Win, Morganti, Marcelli and Strigari https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Oncology
Strolin, Silvia
Paolani, Giulia
Santoro, Miriam
Cercenelli, Laura
Bortolani, Barbara
Ammendolia, Ilario
Cammelli, Silvia
Cicoria, Gianfranco
Win, Phyo Wai
Morganti, Alessio G.
Marcelli, Emanuela
Strigari, Lidia
Improving total body irradiation with a dedicated couch and 3D-printed patient-specific lung blocks: A feasibility study
title Improving total body irradiation with a dedicated couch and 3D-printed patient-specific lung blocks: A feasibility study
title_full Improving total body irradiation with a dedicated couch and 3D-printed patient-specific lung blocks: A feasibility study
title_fullStr Improving total body irradiation with a dedicated couch and 3D-printed patient-specific lung blocks: A feasibility study
title_full_unstemmed Improving total body irradiation with a dedicated couch and 3D-printed patient-specific lung blocks: A feasibility study
title_short Improving total body irradiation with a dedicated couch and 3D-printed patient-specific lung blocks: A feasibility study
title_sort improving total body irradiation with a dedicated couch and 3d-printed patient-specific lung blocks: a feasibility study
topic Oncology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9893493/
https://www.ncbi.nlm.nih.gov/pubmed/36741733
http://dx.doi.org/10.3389/fonc.2022.1046168
work_keys_str_mv AT strolinsilvia improvingtotalbodyirradiationwithadedicatedcouchand3dprintedpatientspecificlungblocksafeasibilitystudy
AT paolanigiulia improvingtotalbodyirradiationwithadedicatedcouchand3dprintedpatientspecificlungblocksafeasibilitystudy
AT santoromiriam improvingtotalbodyirradiationwithadedicatedcouchand3dprintedpatientspecificlungblocksafeasibilitystudy
AT cercenellilaura improvingtotalbodyirradiationwithadedicatedcouchand3dprintedpatientspecificlungblocksafeasibilitystudy
AT bortolanibarbara improvingtotalbodyirradiationwithadedicatedcouchand3dprintedpatientspecificlungblocksafeasibilitystudy
AT ammendoliailario improvingtotalbodyirradiationwithadedicatedcouchand3dprintedpatientspecificlungblocksafeasibilitystudy
AT cammellisilvia improvingtotalbodyirradiationwithadedicatedcouchand3dprintedpatientspecificlungblocksafeasibilitystudy
AT cicoriagianfranco improvingtotalbodyirradiationwithadedicatedcouchand3dprintedpatientspecificlungblocksafeasibilitystudy
AT winphyowai improvingtotalbodyirradiationwithadedicatedcouchand3dprintedpatientspecificlungblocksafeasibilitystudy
AT morgantialessiog improvingtotalbodyirradiationwithadedicatedcouchand3dprintedpatientspecificlungblocksafeasibilitystudy
AT marcelliemanuela improvingtotalbodyirradiationwithadedicatedcouchand3dprintedpatientspecificlungblocksafeasibilitystudy
AT strigarilidia improvingtotalbodyirradiationwithadedicatedcouchand3dprintedpatientspecificlungblocksafeasibilitystudy