Cargando…
Computer-aided diagnosis of primary membranous nephropathy using expert system
BACKGROUND: The diagnosis of primary membranous nephropathy (PMN) often depends on invasive renal biopsy, and the diagnosis based on clinical manifestations and target antigens may not be completely reliable as it could be affected by uncertain factors. Moreover, different experts could even have di...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9893592/ https://www.ncbi.nlm.nih.gov/pubmed/36732817 http://dx.doi.org/10.1186/s12938-023-01063-5 |
Sumario: | BACKGROUND: The diagnosis of primary membranous nephropathy (PMN) often depends on invasive renal biopsy, and the diagnosis based on clinical manifestations and target antigens may not be completely reliable as it could be affected by uncertain factors. Moreover, different experts could even have different diagnosis results due to their different experiences, which could further impact the reliability of the diagnosis. Therefore, how to properly integrate the knowledge of different experts to provide more reliable and comprehensive PMN diagnosis has become an urgent issue. METHODS: This paper develops a belief rule-based system for PMN diagnosis. The belief rule base is constructed based on the knowledge of the experts, with 9 biochemical indicators selected as the input variables. The belief rule-based system is developed of three layers: (1) input layer; (2) belief rule base layer; and (3) output layer, where 9 biochemical indicators are selected as the input variables and the diagnosis result is provided as the conclusion. The belief rule base layer is constructed based on the knowledge of the experts. The final validation was held with gold pattern clinical cases, i.e., with known and clinically confirmed diagnoses. RESULTS: 134 patients are used in this study, and the proposed method is defined by its sensitivity, specificity, accuracy and area under curve (AUC), which are 98.0%, 96.9%, 97.8% and 0.93, respectively. The results of this study present a novel and effective way for PMN diagnosis without the requirement of renal biopsy. CONCLUSIONS: Through analysis of the diagnosis results and comparisons with other methods, it can be concluded that the developed system could help diagnose PMN based on biochemical indicators with relatively high accuracy. GRAPHICAL ABSTRACT: [Image: see text] |
---|