Cargando…

Long-term follow-up of changes in ocular biometric parameters in orthokeratology lens wearers with relatively large-scale axial length reduction

BACKGROUND: To investigate ocular biological characteristics for myopic children with axial length (AL) reduction during orthokeratology (Ortho-K) treatment and provide clinical clues for better myopia control effects. METHODS: Changes in ocular parameters and treatment zone (TZ) in 75 subjects who...

Descripción completa

Detalles Bibliográficos
Autores principales: Tang, Tao, Li, Xuewei, Chen, Sitong, Xu, Qiong, Zhao, Heng, Wang, Kai, Li, Yan, Zhao, Mingwei
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9893609/
https://www.ncbi.nlm.nih.gov/pubmed/36726171
http://dx.doi.org/10.1186/s40662-022-00324-z
_version_ 1784881562673741824
author Tang, Tao
Li, Xuewei
Chen, Sitong
Xu, Qiong
Zhao, Heng
Wang, Kai
Li, Yan
Zhao, Mingwei
author_facet Tang, Tao
Li, Xuewei
Chen, Sitong
Xu, Qiong
Zhao, Heng
Wang, Kai
Li, Yan
Zhao, Mingwei
author_sort Tang, Tao
collection PubMed
description BACKGROUND: To investigate ocular biological characteristics for myopic children with axial length (AL) reduction during orthokeratology (Ortho-K) treatment and provide clinical clues for better myopia control effects. METHODS: Changes in ocular parameters and treatment zone (TZ) in 75 subjects who completed one-year Ortho-K treatment were retrospectively reviewed. The subjects were divided into two groups according to one-year AL change: the AL reduction group (n = 37) and the AL elongation group (n = 38). Univariate and multivariate regression analyses were performed to determine the association between TZ, ocular parameters, and AL change. RESULTS: There was no significant difference in baseline between the two groups (all P > 0.05). After one year of Ortho-K treatment, compared with those in the AL elongation group, children in the AL reduction group had a decreased anterior chamber depth (ACD) (P < 0.001), thickened crystalline lens thickness (CLT) (P = 0.002), thinned vitreous chamber depth (VCD) (P < 0.001) and smaller TZ (P = 0.03), but no difference in central corneal thickness (CCT) and pupil diameter (PD). In the multivariable analyses, AL reduction was negatively associated with baseline age (beta: − 0.048; 95% CI: − 0.083 to − 0.013; P = 0.009) and positively associated with the TZ (beta: 0.024; 95% CI: 0.009 to 0.040; P = 0.003). CONCLUSIONS: In AL reduction eyes, thickened CLT, decreased ACD and thinned VCD were observed during Ortho-K treatment, which could be suggested as indicators for better myopia control effects in the clinic. Older baseline age and smaller TZ wearing Ortho-K were also associated with AL change. Thickened CLT may be a result of compensation for AL-reduction eyes.
format Online
Article
Text
id pubmed-9893609
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-98936092023-02-03 Long-term follow-up of changes in ocular biometric parameters in orthokeratology lens wearers with relatively large-scale axial length reduction Tang, Tao Li, Xuewei Chen, Sitong Xu, Qiong Zhao, Heng Wang, Kai Li, Yan Zhao, Mingwei Eye Vis (Lond) Research BACKGROUND: To investigate ocular biological characteristics for myopic children with axial length (AL) reduction during orthokeratology (Ortho-K) treatment and provide clinical clues for better myopia control effects. METHODS: Changes in ocular parameters and treatment zone (TZ) in 75 subjects who completed one-year Ortho-K treatment were retrospectively reviewed. The subjects were divided into two groups according to one-year AL change: the AL reduction group (n = 37) and the AL elongation group (n = 38). Univariate and multivariate regression analyses were performed to determine the association between TZ, ocular parameters, and AL change. RESULTS: There was no significant difference in baseline between the two groups (all P > 0.05). After one year of Ortho-K treatment, compared with those in the AL elongation group, children in the AL reduction group had a decreased anterior chamber depth (ACD) (P < 0.001), thickened crystalline lens thickness (CLT) (P = 0.002), thinned vitreous chamber depth (VCD) (P < 0.001) and smaller TZ (P = 0.03), but no difference in central corneal thickness (CCT) and pupil diameter (PD). In the multivariable analyses, AL reduction was negatively associated with baseline age (beta: − 0.048; 95% CI: − 0.083 to − 0.013; P = 0.009) and positively associated with the TZ (beta: 0.024; 95% CI: 0.009 to 0.040; P = 0.003). CONCLUSIONS: In AL reduction eyes, thickened CLT, decreased ACD and thinned VCD were observed during Ortho-K treatment, which could be suggested as indicators for better myopia control effects in the clinic. Older baseline age and smaller TZ wearing Ortho-K were also associated with AL change. Thickened CLT may be a result of compensation for AL-reduction eyes. BioMed Central 2023-02-02 /pmc/articles/PMC9893609/ /pubmed/36726171 http://dx.doi.org/10.1186/s40662-022-00324-z Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Research
Tang, Tao
Li, Xuewei
Chen, Sitong
Xu, Qiong
Zhao, Heng
Wang, Kai
Li, Yan
Zhao, Mingwei
Long-term follow-up of changes in ocular biometric parameters in orthokeratology lens wearers with relatively large-scale axial length reduction
title Long-term follow-up of changes in ocular biometric parameters in orthokeratology lens wearers with relatively large-scale axial length reduction
title_full Long-term follow-up of changes in ocular biometric parameters in orthokeratology lens wearers with relatively large-scale axial length reduction
title_fullStr Long-term follow-up of changes in ocular biometric parameters in orthokeratology lens wearers with relatively large-scale axial length reduction
title_full_unstemmed Long-term follow-up of changes in ocular biometric parameters in orthokeratology lens wearers with relatively large-scale axial length reduction
title_short Long-term follow-up of changes in ocular biometric parameters in orthokeratology lens wearers with relatively large-scale axial length reduction
title_sort long-term follow-up of changes in ocular biometric parameters in orthokeratology lens wearers with relatively large-scale axial length reduction
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9893609/
https://www.ncbi.nlm.nih.gov/pubmed/36726171
http://dx.doi.org/10.1186/s40662-022-00324-z
work_keys_str_mv AT tangtao longtermfollowupofchangesinocularbiometricparametersinorthokeratologylenswearerswithrelativelylargescaleaxiallengthreduction
AT lixuewei longtermfollowupofchangesinocularbiometricparametersinorthokeratologylenswearerswithrelativelylargescaleaxiallengthreduction
AT chensitong longtermfollowupofchangesinocularbiometricparametersinorthokeratologylenswearerswithrelativelylargescaleaxiallengthreduction
AT xuqiong longtermfollowupofchangesinocularbiometricparametersinorthokeratologylenswearerswithrelativelylargescaleaxiallengthreduction
AT zhaoheng longtermfollowupofchangesinocularbiometricparametersinorthokeratologylenswearerswithrelativelylargescaleaxiallengthreduction
AT wangkai longtermfollowupofchangesinocularbiometricparametersinorthokeratologylenswearerswithrelativelylargescaleaxiallengthreduction
AT liyan longtermfollowupofchangesinocularbiometricparametersinorthokeratologylenswearerswithrelativelylargescaleaxiallengthreduction
AT zhaomingwei longtermfollowupofchangesinocularbiometricparametersinorthokeratologylenswearerswithrelativelylargescaleaxiallengthreduction