Cargando…

New under the sun: ClotPro's ECA-test detects hyperfibrinolysis in a higher number of patients, more frequently and 9 min earlier

Liver diseases result in a re-balanced state of the haemostatic system with decreased haemostatic reserves. Increased fibrinolytic activity is commonly seen during liver transplants. The aim of this study was to assess whether ClotPro's ECA-test is able to detect hyperfibrinolysis earlier and w...

Descripción completa

Detalles Bibliográficos
Autores principales: Zátroch, István, Dinya, Elek, Fazakas, János
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Lippincott Williams & Wilkins 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9894133/
https://www.ncbi.nlm.nih.gov/pubmed/36519572
http://dx.doi.org/10.1097/MBC.0000000000001185
_version_ 1784881677465550848
author Zátroch, István
Dinya, Elek
Fazakas, János
author_facet Zátroch, István
Dinya, Elek
Fazakas, János
author_sort Zátroch, István
collection PubMed
description Liver diseases result in a re-balanced state of the haemostatic system with decreased haemostatic reserves. Increased fibrinolytic activity is commonly seen during liver transplants. The aim of this study was to assess whether ClotPro's ECA-test is able to detect hyperfibrinolysis earlier and with higher frequency than ClotPro's conventional viscoelastic assays for the intrinsic and the extrinsic coagulation pathway. From 25 liver transplant recipients, systemic blood samples were collected during surgery. Viscoelastic haemostatic assays with ClotPro's IN-test, EX-test and ECA-test were performed simultaneously from each blood sample. Hyperfibrinolysis was defined on the basis of the manufacturer's prespecified threshold value (maximal lysis >15%). The incidence of hyperfibrinolysis detected with each test was compared with the McNemar test. For each assay, lysis detection time (LDT) was calculated and analysed with the nonparametric Kruskal–Wallis test. A total of 125 tests were performed simultaneously. Compared with the IN-test and the EX-test, the ECA-test detected hyperfibrinolysis in significantly (P < 0.001) higher number of patients (9; 11; 14, respectively) and in more measurement points (14; 18; 28, respectively). The analysis of LDT values revealed significant superiority of the ECA-test to the IN-test (P = 0.046) and to the EX-test (P = 0.035), indicating the profibrinolytic state of the haemostasis 8.9 ± 0.65 and 8.7 ± 0.17 min earlier, respectively. These are preliminary results of the study NCT0424637. ClotPro's ECA-test appeared to detect fibrinolysis in a higher number of patients, more frequently, and the mean time of detection was 9 min earlier than that of the IN-test and the EX-test.
format Online
Article
Text
id pubmed-9894133
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Lippincott Williams & Wilkins
record_format MEDLINE/PubMed
spelling pubmed-98941332023-02-07 New under the sun: ClotPro's ECA-test detects hyperfibrinolysis in a higher number of patients, more frequently and 9 min earlier Zátroch, István Dinya, Elek Fazakas, János Blood Coagul Fibrinolysis Original Articles Liver diseases result in a re-balanced state of the haemostatic system with decreased haemostatic reserves. Increased fibrinolytic activity is commonly seen during liver transplants. The aim of this study was to assess whether ClotPro's ECA-test is able to detect hyperfibrinolysis earlier and with higher frequency than ClotPro's conventional viscoelastic assays for the intrinsic and the extrinsic coagulation pathway. From 25 liver transplant recipients, systemic blood samples were collected during surgery. Viscoelastic haemostatic assays with ClotPro's IN-test, EX-test and ECA-test were performed simultaneously from each blood sample. Hyperfibrinolysis was defined on the basis of the manufacturer's prespecified threshold value (maximal lysis >15%). The incidence of hyperfibrinolysis detected with each test was compared with the McNemar test. For each assay, lysis detection time (LDT) was calculated and analysed with the nonparametric Kruskal–Wallis test. A total of 125 tests were performed simultaneously. Compared with the IN-test and the EX-test, the ECA-test detected hyperfibrinolysis in significantly (P < 0.001) higher number of patients (9; 11; 14, respectively) and in more measurement points (14; 18; 28, respectively). The analysis of LDT values revealed significant superiority of the ECA-test to the IN-test (P = 0.046) and to the EX-test (P = 0.035), indicating the profibrinolytic state of the haemostasis 8.9 ± 0.65 and 8.7 ± 0.17 min earlier, respectively. These are preliminary results of the study NCT0424637. ClotPro's ECA-test appeared to detect fibrinolysis in a higher number of patients, more frequently, and the mean time of detection was 9 min earlier than that of the IN-test and the EX-test. Lippincott Williams & Wilkins 2023-03 2022-12-15 /pmc/articles/PMC9894133/ /pubmed/36519572 http://dx.doi.org/10.1097/MBC.0000000000001185 Text en Copyright © 2022 The Author(s). Published by Wolters Kluwer Health, Inc. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article distributed under the terms of the Creative Commons Attribution-Non Commercial-No Derivatives License 4.0 (CCBY-NC-ND), where it is permissible to download and share the work provided it is properly cited. The work cannot be changed in any way or used commercially without permission from the journal. http://creativecommons.org/licenses/by-nc-nd/4.0 (https://creativecommons.org/licenses/by-nc-nd/4.0/)
spellingShingle Original Articles
Zátroch, István
Dinya, Elek
Fazakas, János
New under the sun: ClotPro's ECA-test detects hyperfibrinolysis in a higher number of patients, more frequently and 9 min earlier
title New under the sun: ClotPro's ECA-test detects hyperfibrinolysis in a higher number of patients, more frequently and 9 min earlier
title_full New under the sun: ClotPro's ECA-test detects hyperfibrinolysis in a higher number of patients, more frequently and 9 min earlier
title_fullStr New under the sun: ClotPro's ECA-test detects hyperfibrinolysis in a higher number of patients, more frequently and 9 min earlier
title_full_unstemmed New under the sun: ClotPro's ECA-test detects hyperfibrinolysis in a higher number of patients, more frequently and 9 min earlier
title_short New under the sun: ClotPro's ECA-test detects hyperfibrinolysis in a higher number of patients, more frequently and 9 min earlier
title_sort new under the sun: clotpro's eca-test detects hyperfibrinolysis in a higher number of patients, more frequently and 9 min earlier
topic Original Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9894133/
https://www.ncbi.nlm.nih.gov/pubmed/36519572
http://dx.doi.org/10.1097/MBC.0000000000001185
work_keys_str_mv AT zatrochistvan newunderthesunclotprosecatestdetectshyperfibrinolysisinahighernumberofpatientsmorefrequentlyand9minearlier
AT dinyaelek newunderthesunclotprosecatestdetectshyperfibrinolysisinahighernumberofpatientsmorefrequentlyand9minearlier
AT fazakasjanos newunderthesunclotprosecatestdetectshyperfibrinolysisinahighernumberofpatientsmorefrequentlyand9minearlier