Cargando…
Evaluating sleep in covert encephalopathy with wearable technology: results from the WATCHES study
Covert HE (CHE) is a common early stage of HE associated with poor outcomes. Available neuropsychiatric diagnostic testing is underutilized and has significant clinical limitations. Sleep deterioration is consistently associated with CHE and HE; however, objective data is sparse and it has not been...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Lippincott Williams & Wilkins
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9894338/ https://www.ncbi.nlm.nih.gov/pubmed/36724117 http://dx.doi.org/10.1097/HC9.0000000000000028 |
_version_ | 1784881720177197056 |
---|---|
author | Buckholz, Adam Clarke, Lindsay Paik, Paul Jesudian, Arun Schwartz, Robert Krieger, Ana Rosenblatt, Russell Brown, Robert S. |
author_facet | Buckholz, Adam Clarke, Lindsay Paik, Paul Jesudian, Arun Schwartz, Robert Krieger, Ana Rosenblatt, Russell Brown, Robert S. |
author_sort | Buckholz, Adam |
collection | PubMed |
description | Covert HE (CHE) is a common early stage of HE associated with poor outcomes. Available neuropsychiatric diagnostic testing is underutilized and has significant clinical limitations. Sleep deterioration is consistently associated with CHE and HE; however, objective data is sparse and it has not been studied longitudinally. We longitudinally study and describe an association of sleep metrics with CHE as detected by a commercial wearable technology. METHODS: We monitored sleep for 6 months using a commercial fitness tracker in 25 participants with cirrhosis, hypothesizing that CHE as diagnosed by psychometric testing would be associated with significant reductions in sleep quality, especially restorative sleep (deep sleep + rapid eye movement). Mixed-effects modeling was performed to evaluate sleep factors associated with CHE and developed and internally validated a score based on these sleep metrics for associated CHE. RESULTS: Across 2862 nights with 66.3% study adherence, we found that those with CHE had consistently worse sleep, including an average of 1 hour less of nightly restorative sleep, driven primarily by reductions in rapid eye movement. A model including albumin, bilirubin, rapid eye movement, sleep disturbances, and sleep consistency showed good discrimination (area under the receiver operating curve=0.79) for CHE status with a sensitivity of 76% and specificity of 69%. CONCLUSIONS: Our large longitudinal study of sleep in cirrhosis suggests that sleep derangements in CHE can be detected using wearable technology. Given the known importance of sleep to overall health and CHE/HE to prognosis in cirrhosis, the ability to associate dynamic sleep metrics with CHE may in the future help with the detection and passive monitoring as factors that precipitate decompensation of cirrhosis become better understood and mobile health data validation and integration improves. |
format | Online Article Text |
id | pubmed-9894338 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Lippincott Williams & Wilkins |
record_format | MEDLINE/PubMed |
spelling | pubmed-98943382023-03-16 Evaluating sleep in covert encephalopathy with wearable technology: results from the WATCHES study Buckholz, Adam Clarke, Lindsay Paik, Paul Jesudian, Arun Schwartz, Robert Krieger, Ana Rosenblatt, Russell Brown, Robert S. Hepatol Commun Original Articles Covert HE (CHE) is a common early stage of HE associated with poor outcomes. Available neuropsychiatric diagnostic testing is underutilized and has significant clinical limitations. Sleep deterioration is consistently associated with CHE and HE; however, objective data is sparse and it has not been studied longitudinally. We longitudinally study and describe an association of sleep metrics with CHE as detected by a commercial wearable technology. METHODS: We monitored sleep for 6 months using a commercial fitness tracker in 25 participants with cirrhosis, hypothesizing that CHE as diagnosed by psychometric testing would be associated with significant reductions in sleep quality, especially restorative sleep (deep sleep + rapid eye movement). Mixed-effects modeling was performed to evaluate sleep factors associated with CHE and developed and internally validated a score based on these sleep metrics for associated CHE. RESULTS: Across 2862 nights with 66.3% study adherence, we found that those with CHE had consistently worse sleep, including an average of 1 hour less of nightly restorative sleep, driven primarily by reductions in rapid eye movement. A model including albumin, bilirubin, rapid eye movement, sleep disturbances, and sleep consistency showed good discrimination (area under the receiver operating curve=0.79) for CHE status with a sensitivity of 76% and specificity of 69%. CONCLUSIONS: Our large longitudinal study of sleep in cirrhosis suggests that sleep derangements in CHE can be detected using wearable technology. Given the known importance of sleep to overall health and CHE/HE to prognosis in cirrhosis, the ability to associate dynamic sleep metrics with CHE may in the future help with the detection and passive monitoring as factors that precipitate decompensation of cirrhosis become better understood and mobile health data validation and integration improves. Lippincott Williams & Wilkins 2023-02-01 /pmc/articles/PMC9894338/ /pubmed/36724117 http://dx.doi.org/10.1097/HC9.0000000000000028 Text en Copyright © 2023 The Author(s). Published by Wolters Kluwer Health, Inc. on behalf of the American Association for the Study of Liver Diseases. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article distributed under the terms of the Creative Commons Attribution-Non Commercial-No Derivatives License 4.0 (https://creativecommons.org/licenses/by-nc-nd/4.0/) (CCBY-NC-ND), where it is permissible to download and share the work provided it is properly cited. The work cannot be changed in any way or used commercially without permission from the journal. http://creativecommons.org/licenses/by-nc-nd/4.0/ (https://creativecommons.org/licenses/by-nc-nd/4.0/) |
spellingShingle | Original Articles Buckholz, Adam Clarke, Lindsay Paik, Paul Jesudian, Arun Schwartz, Robert Krieger, Ana Rosenblatt, Russell Brown, Robert S. Evaluating sleep in covert encephalopathy with wearable technology: results from the WATCHES study |
title | Evaluating sleep in covert encephalopathy with wearable technology: results from the WATCHES study |
title_full | Evaluating sleep in covert encephalopathy with wearable technology: results from the WATCHES study |
title_fullStr | Evaluating sleep in covert encephalopathy with wearable technology: results from the WATCHES study |
title_full_unstemmed | Evaluating sleep in covert encephalopathy with wearable technology: results from the WATCHES study |
title_short | Evaluating sleep in covert encephalopathy with wearable technology: results from the WATCHES study |
title_sort | evaluating sleep in covert encephalopathy with wearable technology: results from the watches study |
topic | Original Articles |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9894338/ https://www.ncbi.nlm.nih.gov/pubmed/36724117 http://dx.doi.org/10.1097/HC9.0000000000000028 |
work_keys_str_mv | AT buckholzadam evaluatingsleepincovertencephalopathywithwearabletechnologyresultsfromthewatchesstudy AT clarkelindsay evaluatingsleepincovertencephalopathywithwearabletechnologyresultsfromthewatchesstudy AT paikpaul evaluatingsleepincovertencephalopathywithwearabletechnologyresultsfromthewatchesstudy AT jesudianarun evaluatingsleepincovertencephalopathywithwearabletechnologyresultsfromthewatchesstudy AT schwartzrobert evaluatingsleepincovertencephalopathywithwearabletechnologyresultsfromthewatchesstudy AT kriegerana evaluatingsleepincovertencephalopathywithwearabletechnologyresultsfromthewatchesstudy AT rosenblattrussell evaluatingsleepincovertencephalopathywithwearabletechnologyresultsfromthewatchesstudy AT brownroberts evaluatingsleepincovertencephalopathywithwearabletechnologyresultsfromthewatchesstudy |