Cargando…

Usefulness of 4K-resolution Indocyanine Green Endoscope for the Removal of Spontaneous Intracerebral Hematomas

Indocyanine green (ICG) is a cyanine dye useful for visualizing blood vessels; it has been developed for endoscopy and is used in skull base surgery. Endoscopy is widely used for hematoma removal after an intracerebral hemorrhage since it is minimally invasive and has a shorter operation time than c...

Descripción completa

Detalles Bibliográficos
Autores principales: NOUNAKA, Yohei, TAHARA, Shigeyuki, SASAKI, Kazuma, MORITA, Akio
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Japan Neurosurgical Society 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9894616/
https://www.ncbi.nlm.nih.gov/pubmed/36642502
http://dx.doi.org/10.2176/jns-nmc.2022-0135
_version_ 1784881776981704704
author NOUNAKA, Yohei
TAHARA, Shigeyuki
SASAKI, Kazuma
MORITA, Akio
author_facet NOUNAKA, Yohei
TAHARA, Shigeyuki
SASAKI, Kazuma
MORITA, Akio
author_sort NOUNAKA, Yohei
collection PubMed
description Indocyanine green (ICG) is a cyanine dye useful for visualizing blood vessels; it has been developed for endoscopy and is used in skull base surgery. Endoscopy is widely used for hematoma removal after an intracerebral hemorrhage since it is minimally invasive and has a shorter operation time than craniotomy. However, with this technique the surgical field is limited and it is difficult to obtain an adequate orientation; thus, it is challenging to locate the bleeding point, and postoperative rebleeding has been reported. We performed intraoperative ICG near-infrared fluorescence imaging to locate the bleeding point. This purpose of this study was to evaluate the usefulness of ICG angiography during endoscopic hematoma removal in two patients, using two endoscope types and comparing their visualization of perforating branches during the procedure. ICG angiography was performed in two different cases of putaminal hemorrhage, using the SPIES NIR/ICG-System and IMAGE1 S Rubina (both KARL STORZ, Tuttlingen, Germany) at the intraoperative bleeding site. The intraoperative use of ICG allowed the clear visualization of the perforating branches and real-time confirmation of active bleeding. We could also distinguish an old hematoma from the active bleeding point. The IMAGE1 S Rubina has adequate brightness for contrast enhancement, allowing surgical manipulation simultaneously to the enhancement phase. ICG fluorescence angiography is useful to identify the damaged vessel and perform hemostasis. We expect other similar devices to be developed in the future, accompanied by flexible and thin rigid endoscopes.
format Online
Article
Text
id pubmed-9894616
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher The Japan Neurosurgical Society
record_format MEDLINE/PubMed
spelling pubmed-98946162023-02-13 Usefulness of 4K-resolution Indocyanine Green Endoscope for the Removal of Spontaneous Intracerebral Hematomas NOUNAKA, Yohei TAHARA, Shigeyuki SASAKI, Kazuma MORITA, Akio Neurol Med Chir (Tokyo) Technical Note Indocyanine green (ICG) is a cyanine dye useful for visualizing blood vessels; it has been developed for endoscopy and is used in skull base surgery. Endoscopy is widely used for hematoma removal after an intracerebral hemorrhage since it is minimally invasive and has a shorter operation time than craniotomy. However, with this technique the surgical field is limited and it is difficult to obtain an adequate orientation; thus, it is challenging to locate the bleeding point, and postoperative rebleeding has been reported. We performed intraoperative ICG near-infrared fluorescence imaging to locate the bleeding point. This purpose of this study was to evaluate the usefulness of ICG angiography during endoscopic hematoma removal in two patients, using two endoscope types and comparing their visualization of perforating branches during the procedure. ICG angiography was performed in two different cases of putaminal hemorrhage, using the SPIES NIR/ICG-System and IMAGE1 S Rubina (both KARL STORZ, Tuttlingen, Germany) at the intraoperative bleeding site. The intraoperative use of ICG allowed the clear visualization of the perforating branches and real-time confirmation of active bleeding. We could also distinguish an old hematoma from the active bleeding point. The IMAGE1 S Rubina has adequate brightness for contrast enhancement, allowing surgical manipulation simultaneously to the enhancement phase. ICG fluorescence angiography is useful to identify the damaged vessel and perform hemostasis. We expect other similar devices to be developed in the future, accompanied by flexible and thin rigid endoscopes. The Japan Neurosurgical Society 2023-01-15 /pmc/articles/PMC9894616/ /pubmed/36642502 http://dx.doi.org/10.2176/jns-nmc.2022-0135 Text en © 2023 The Japan Neurosurgical Society https://creativecommons.org/licenses/by-nc-nd/4.0/This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives International License.
spellingShingle Technical Note
NOUNAKA, Yohei
TAHARA, Shigeyuki
SASAKI, Kazuma
MORITA, Akio
Usefulness of 4K-resolution Indocyanine Green Endoscope for the Removal of Spontaneous Intracerebral Hematomas
title Usefulness of 4K-resolution Indocyanine Green Endoscope for the Removal of Spontaneous Intracerebral Hematomas
title_full Usefulness of 4K-resolution Indocyanine Green Endoscope for the Removal of Spontaneous Intracerebral Hematomas
title_fullStr Usefulness of 4K-resolution Indocyanine Green Endoscope for the Removal of Spontaneous Intracerebral Hematomas
title_full_unstemmed Usefulness of 4K-resolution Indocyanine Green Endoscope for the Removal of Spontaneous Intracerebral Hematomas
title_short Usefulness of 4K-resolution Indocyanine Green Endoscope for the Removal of Spontaneous Intracerebral Hematomas
title_sort usefulness of 4k-resolution indocyanine green endoscope for the removal of spontaneous intracerebral hematomas
topic Technical Note
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9894616/
https://www.ncbi.nlm.nih.gov/pubmed/36642502
http://dx.doi.org/10.2176/jns-nmc.2022-0135
work_keys_str_mv AT nounakayohei usefulnessof4kresolutionindocyaninegreenendoscopefortheremovalofspontaneousintracerebralhematomas
AT taharashigeyuki usefulnessof4kresolutionindocyaninegreenendoscopefortheremovalofspontaneousintracerebralhematomas
AT sasakikazuma usefulnessof4kresolutionindocyaninegreenendoscopefortheremovalofspontaneousintracerebralhematomas
AT moritaakio usefulnessof4kresolutionindocyaninegreenendoscopefortheremovalofspontaneousintracerebralhematomas