Cargando…

Applicability of on-site disinfection of personal protective equipment by ozone gas

On-site disinfection techniques are beneficial during a pandemic when there is a marked shortage of personal protective equipment (PPE), as experienced during the coronavirus disease 2019 outbreak. Ozone gas has been considered an alternative on-site disinfectant during a pandemic because it has ant...

Descripción completa

Detalles Bibliográficos
Autores principales: Ishiwata, Shunji, Hibino, Taishi, Sakashita, Tomoe, Nishioka, Manami, Inoue, Tomomi, Kotake, Takeshi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9894677/
https://www.ncbi.nlm.nih.gov/pubmed/36776915
http://dx.doi.org/10.1016/j.heliyon.2023.e13360
_version_ 1784881789646405632
author Ishiwata, Shunji
Hibino, Taishi
Sakashita, Tomoe
Nishioka, Manami
Inoue, Tomomi
Kotake, Takeshi
author_facet Ishiwata, Shunji
Hibino, Taishi
Sakashita, Tomoe
Nishioka, Manami
Inoue, Tomomi
Kotake, Takeshi
author_sort Ishiwata, Shunji
collection PubMed
description On-site disinfection techniques are beneficial during a pandemic when there is a marked shortage of personal protective equipment (PPE), as experienced during the coronavirus disease 2019 outbreak. Ozone gas has been considered an alternative on-site disinfectant during a pandemic because it has antimicrobial activities, can be produced from air by electricity without the need for storage, and can be easily deactivated after use. However, ozone gas might become distributed at the lower layer because it has a larger molecular weight than air. This study aimed to reveal the applicability of ozone gas for the on-site disinfection of PPE. The lockers meant for changing dresses were used as ozone gas exposure boxes, and the distribution of ozone was assayed. Considering that the determined ozone levels were not consistent in the types of ozone analysers, we studied the chemical and biological activities of ozone, which were evenly detected in the locker. The gown in the locker was also uniformly exposed to ozone. Results showed that ozone gas could be used for the on-site disinfection of PPE in a closed box, such as a locker. This finding is valuable during a pandemic when PPE is in short supply.
format Online
Article
Text
id pubmed-9894677
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-98946772023-02-06 Applicability of on-site disinfection of personal protective equipment by ozone gas Ishiwata, Shunji Hibino, Taishi Sakashita, Tomoe Nishioka, Manami Inoue, Tomomi Kotake, Takeshi Heliyon Research Article On-site disinfection techniques are beneficial during a pandemic when there is a marked shortage of personal protective equipment (PPE), as experienced during the coronavirus disease 2019 outbreak. Ozone gas has been considered an alternative on-site disinfectant during a pandemic because it has antimicrobial activities, can be produced from air by electricity without the need for storage, and can be easily deactivated after use. However, ozone gas might become distributed at the lower layer because it has a larger molecular weight than air. This study aimed to reveal the applicability of ozone gas for the on-site disinfection of PPE. The lockers meant for changing dresses were used as ozone gas exposure boxes, and the distribution of ozone was assayed. Considering that the determined ozone levels were not consistent in the types of ozone analysers, we studied the chemical and biological activities of ozone, which were evenly detected in the locker. The gown in the locker was also uniformly exposed to ozone. Results showed that ozone gas could be used for the on-site disinfection of PPE in a closed box, such as a locker. This finding is valuable during a pandemic when PPE is in short supply. Elsevier 2023-02-03 /pmc/articles/PMC9894677/ /pubmed/36776915 http://dx.doi.org/10.1016/j.heliyon.2023.e13360 Text en © 2023 The Authors https://creativecommons.org/licenses/by/4.0/This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Research Article
Ishiwata, Shunji
Hibino, Taishi
Sakashita, Tomoe
Nishioka, Manami
Inoue, Tomomi
Kotake, Takeshi
Applicability of on-site disinfection of personal protective equipment by ozone gas
title Applicability of on-site disinfection of personal protective equipment by ozone gas
title_full Applicability of on-site disinfection of personal protective equipment by ozone gas
title_fullStr Applicability of on-site disinfection of personal protective equipment by ozone gas
title_full_unstemmed Applicability of on-site disinfection of personal protective equipment by ozone gas
title_short Applicability of on-site disinfection of personal protective equipment by ozone gas
title_sort applicability of on-site disinfection of personal protective equipment by ozone gas
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9894677/
https://www.ncbi.nlm.nih.gov/pubmed/36776915
http://dx.doi.org/10.1016/j.heliyon.2023.e13360
work_keys_str_mv AT ishiwatashunji applicabilityofonsitedisinfectionofpersonalprotectiveequipmentbyozonegas
AT hibinotaishi applicabilityofonsitedisinfectionofpersonalprotectiveequipmentbyozonegas
AT sakashitatomoe applicabilityofonsitedisinfectionofpersonalprotectiveequipmentbyozonegas
AT nishiokamanami applicabilityofonsitedisinfectionofpersonalprotectiveequipmentbyozonegas
AT inouetomomi applicabilityofonsitedisinfectionofpersonalprotectiveequipmentbyozonegas
AT kotaketakeshi applicabilityofonsitedisinfectionofpersonalprotectiveequipmentbyozonegas