OLSA-Pegelsteuerung bei monauraler Sprachaudiometrie im Störschall zur Evaluation des CI-Versorgungsergebnisses
Scientific background: Speech audiometry measurements under the influence of background noise are a fundamental part of evaluating the outcome of hearing care. As yet far, there are no recommendations for selecting a suitable method for adaptive speech audiometry measurements in background noise in...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer Medizin
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9894967/ https://www.ncbi.nlm.nih.gov/pubmed/36469098 http://dx.doi.org/10.1007/s00106-022-01251-0 |
_version_ | 1784881847285579776 |
---|---|
author | Dziemba, Oliver C. Oberhoffner, Tobias Müller, Alexander |
author_facet | Dziemba, Oliver C. Oberhoffner, Tobias Müller, Alexander |
author_sort | Dziemba, Oliver C. |
collection | PubMed |
description | Scientific background: Speech audiometry measurements under the influence of background noise are a fundamental part of evaluating the outcome of hearing care. As yet far, there are no recommendations for selecting a suitable method for adaptive speech audiometry measurements in background noise in cochlear implant (CI) care, so either the choice the adaptive level change of the speech signal (S) with constant noise (N) or the adaptive level change of N with constant S. Objectives: Do the measurement results of the monaural speechrecognition threshold in noise (SRT) with the Oldenburg Sentence Test (OLSA) depend on the choice of level control? Material and methods: A total of 50 series of measurements with OLSA in noise and the Freiburg speech intelligibility test in quiet (FBE) on middle-aged CI patients from clinical routine. Results: There is no significant difference in the measurement results with different level controls when the SRT is less than 5 [Formula: see text] . Below 55 % monosyllabic intelligibility in quiet, the SRT in noise becomes greater than 5 [Formula: see text] . Conclusion: From a clinical, audiological and methodological point of view, it is advisable to carry out the adaptive monaural speech intelligibility measurement with a constant speech signal at 65 [Formula: see text] . |
format | Online Article Text |
id | pubmed-9894967 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Springer Medizin |
record_format | MEDLINE/PubMed |
spelling | pubmed-98949672023-02-04 OLSA-Pegelsteuerung bei monauraler Sprachaudiometrie im Störschall zur Evaluation des CI-Versorgungsergebnisses Dziemba, Oliver C. Oberhoffner, Tobias Müller, Alexander HNO Originalien Scientific background: Speech audiometry measurements under the influence of background noise are a fundamental part of evaluating the outcome of hearing care. As yet far, there are no recommendations for selecting a suitable method for adaptive speech audiometry measurements in background noise in cochlear implant (CI) care, so either the choice the adaptive level change of the speech signal (S) with constant noise (N) or the adaptive level change of N with constant S. Objectives: Do the measurement results of the monaural speechrecognition threshold in noise (SRT) with the Oldenburg Sentence Test (OLSA) depend on the choice of level control? Material and methods: A total of 50 series of measurements with OLSA in noise and the Freiburg speech intelligibility test in quiet (FBE) on middle-aged CI patients from clinical routine. Results: There is no significant difference in the measurement results with different level controls when the SRT is less than 5 [Formula: see text] . Below 55 % monosyllabic intelligibility in quiet, the SRT in noise becomes greater than 5 [Formula: see text] . Conclusion: From a clinical, audiological and methodological point of view, it is advisable to carry out the adaptive monaural speech intelligibility measurement with a constant speech signal at 65 [Formula: see text] . Springer Medizin 2022-12-05 2023 /pmc/articles/PMC9894967/ /pubmed/36469098 http://dx.doi.org/10.1007/s00106-022-01251-0 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open Access Dieser Artikel wird unter der Creative Commons Namensnennung 4.0 International Lizenz veröffentlicht, welche die Nutzung, Vervielfältigung, Bearbeitung, Verbreitung und Wiedergabe in jeglichem Medium und Format erlaubt, sofern Sie den/die ursprünglichen Autor(en) und die Quelle ordnungsgemäß nennen, einen Link zur Creative Commons Lizenz beifügen und angeben, ob Änderungen vorgenommen wurden. Die in diesem Artikel enthaltenen Bilder und sonstiges Drittmaterial unterliegen ebenfalls der genannten Creative Commons Lizenz, sofern sich aus der Abbildungslegende nichts anderes ergibt. Sofern das betreffende Material nicht unter der genannten Creative Commons Lizenz steht und die betreffende Handlung nicht nach gesetzlichen Vorschriften erlaubt ist, ist für die oben aufgeführten Weiterverwendungen des Materials die Einwilligung des jeweiligen Rechteinhabers einzuholen. Weitere Details zur Lizenz entnehmen Sie bitte der Lizenzinformation auf http://creativecommons.org/licenses/by/4.0/deed.de (https://creativecommons.org/licenses/by/4.0/) . |
spellingShingle | Originalien Dziemba, Oliver C. Oberhoffner, Tobias Müller, Alexander OLSA-Pegelsteuerung bei monauraler Sprachaudiometrie im Störschall zur Evaluation des CI-Versorgungsergebnisses |
title | OLSA-Pegelsteuerung bei monauraler Sprachaudiometrie im Störschall zur Evaluation des CI-Versorgungsergebnisses |
title_full | OLSA-Pegelsteuerung bei monauraler Sprachaudiometrie im Störschall zur Evaluation des CI-Versorgungsergebnisses |
title_fullStr | OLSA-Pegelsteuerung bei monauraler Sprachaudiometrie im Störschall zur Evaluation des CI-Versorgungsergebnisses |
title_full_unstemmed | OLSA-Pegelsteuerung bei monauraler Sprachaudiometrie im Störschall zur Evaluation des CI-Versorgungsergebnisses |
title_short | OLSA-Pegelsteuerung bei monauraler Sprachaudiometrie im Störschall zur Evaluation des CI-Versorgungsergebnisses |
title_sort | olsa-pegelsteuerung bei monauraler sprachaudiometrie im störschall zur evaluation des ci-versorgungsergebnisses |
topic | Originalien |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9894967/ https://www.ncbi.nlm.nih.gov/pubmed/36469098 http://dx.doi.org/10.1007/s00106-022-01251-0 |
work_keys_str_mv | AT dziembaoliverc olsapegelsteuerungbeimonauralersprachaudiometrieimstorschallzurevaluationdesciversorgungsergebnisses AT oberhoffnertobias olsapegelsteuerungbeimonauralersprachaudiometrieimstorschallzurevaluationdesciversorgungsergebnisses AT mulleralexander olsapegelsteuerungbeimonauralersprachaudiometrieimstorschallzurevaluationdesciversorgungsergebnisses |