Cargando…
Stellenwert der Computertomographie in der präoperativen Diagnostik der Otosklerose
BACKGROUND: Otosclerosis is an osteodystrophy of the otic capsule and presents with progressive conductive hearing loss. Imaging studies, especially computed tomography (CT) and cone-beam CT, have gained increased relevance in the diagnosis of otosclerosis. OBJECTIVE: This study investigated whether...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer Medizin
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9895003/ https://www.ncbi.nlm.nih.gov/pubmed/36326852 http://dx.doi.org/10.1007/s00106-022-01241-2 |
_version_ | 1784881855768559616 |
---|---|
author | Stenz, Nadja Angela Hashmi, Salman Lehnick, Dirk Treumann, Thomas Linder, Thomas |
author_facet | Stenz, Nadja Angela Hashmi, Salman Lehnick, Dirk Treumann, Thomas Linder, Thomas |
author_sort | Stenz, Nadja Angela |
collection | PubMed |
description | BACKGROUND: Otosclerosis is an osteodystrophy of the otic capsule and presents with progressive conductive hearing loss. Imaging studies, especially computed tomography (CT) and cone-beam CT, have gained increased relevance in the diagnosis of otosclerosis. OBJECTIVE: This study investigated whether there is a correlation between the extent of otosclerosis in high-resolution or cone-beam CT and hearing loss in pure-tone audiometry. MATERIALS AND METHODS: Based on an existing classification of otosclerotic foci, a classification was established. Preoperative CT scans of patients undergoing stapedotomy between 2015 and 2019 were evaluated and classified by two independent otorhinolaryngologists. The preoperative pure-tone audiograms were analysed and compared to the results of CT. RESULTS: A total of 168 CT studies (i.e., 168 ears) in 156 patients with intraoperatively confirmed otosclerosis were included in our study. A correlation between the extent of the otosclerotic focus or the calculated scores and hearing loss in pure-tone audiometry (air conduction, bone conduction and air-bone-gap) could not be proven. CONCLUSION: Preoperative CT is not obligatory. However, preoperative imaging using CT or cone-beam CT can be helpful to confirm the diagnosis and exclude other middle or inner ear pathologies as well as in planning of the surgical procedure in the overall context of otoscopy and audiometry. A correlation with the degree of hearing impairment could not be demonstrated and remains unclear. |
format | Online Article Text |
id | pubmed-9895003 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Springer Medizin |
record_format | MEDLINE/PubMed |
spelling | pubmed-98950032023-02-04 Stellenwert der Computertomographie in der präoperativen Diagnostik der Otosklerose Stenz, Nadja Angela Hashmi, Salman Lehnick, Dirk Treumann, Thomas Linder, Thomas HNO Originalien BACKGROUND: Otosclerosis is an osteodystrophy of the otic capsule and presents with progressive conductive hearing loss. Imaging studies, especially computed tomography (CT) and cone-beam CT, have gained increased relevance in the diagnosis of otosclerosis. OBJECTIVE: This study investigated whether there is a correlation between the extent of otosclerosis in high-resolution or cone-beam CT and hearing loss in pure-tone audiometry. MATERIALS AND METHODS: Based on an existing classification of otosclerotic foci, a classification was established. Preoperative CT scans of patients undergoing stapedotomy between 2015 and 2019 were evaluated and classified by two independent otorhinolaryngologists. The preoperative pure-tone audiograms were analysed and compared to the results of CT. RESULTS: A total of 168 CT studies (i.e., 168 ears) in 156 patients with intraoperatively confirmed otosclerosis were included in our study. A correlation between the extent of the otosclerotic focus or the calculated scores and hearing loss in pure-tone audiometry (air conduction, bone conduction and air-bone-gap) could not be proven. CONCLUSION: Preoperative CT is not obligatory. However, preoperative imaging using CT or cone-beam CT can be helpful to confirm the diagnosis and exclude other middle or inner ear pathologies as well as in planning of the surgical procedure in the overall context of otoscopy and audiometry. A correlation with the degree of hearing impairment could not be demonstrated and remains unclear. Springer Medizin 2022-11-03 2023 /pmc/articles/PMC9895003/ /pubmed/36326852 http://dx.doi.org/10.1007/s00106-022-01241-2 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open Access Dieser Artikel wird unter der Creative Commons Namensnennung 4.0 International Lizenz veröffentlicht, welche die Nutzung, Vervielfältigung, Bearbeitung, Verbreitung und Wiedergabe in jeglichem Medium und Format erlaubt, sofern Sie den/die ursprünglichen Autor(en) und die Quelle ordnungsgemäß nennen, einen Link zur Creative Commons Lizenz beifügen und angeben, ob Änderungen vorgenommen wurden. Die in diesem Artikel enthaltenen Bilder und sonstiges Drittmaterial unterliegen ebenfalls der genannten Creative Commons Lizenz, sofern sich aus der Abbildungslegende nichts anderes ergibt. Sofern das betreffende Material nicht unter der genannten Creative Commons Lizenz steht und die betreffende Handlung nicht nach gesetzlichen Vorschriften erlaubt ist, ist für die oben aufgeführten Weiterverwendungen des Materials die Einwilligung des jeweiligen Rechteinhabers einzuholen. Weitere Details zur Lizenz entnehmen Sie bitte der Lizenzinformation auf http://creativecommons.org/licenses/by/4.0/deed.de (https://creativecommons.org/licenses/by/4.0/) . |
spellingShingle | Originalien Stenz, Nadja Angela Hashmi, Salman Lehnick, Dirk Treumann, Thomas Linder, Thomas Stellenwert der Computertomographie in der präoperativen Diagnostik der Otosklerose |
title | Stellenwert der Computertomographie in der präoperativen Diagnostik der Otosklerose |
title_full | Stellenwert der Computertomographie in der präoperativen Diagnostik der Otosklerose |
title_fullStr | Stellenwert der Computertomographie in der präoperativen Diagnostik der Otosklerose |
title_full_unstemmed | Stellenwert der Computertomographie in der präoperativen Diagnostik der Otosklerose |
title_short | Stellenwert der Computertomographie in der präoperativen Diagnostik der Otosklerose |
title_sort | stellenwert der computertomographie in der präoperativen diagnostik der otosklerose |
topic | Originalien |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9895003/ https://www.ncbi.nlm.nih.gov/pubmed/36326852 http://dx.doi.org/10.1007/s00106-022-01241-2 |
work_keys_str_mv | AT stenznadjaangela stellenwertdercomputertomographieinderpraoperativendiagnostikderotosklerose AT hashmisalman stellenwertdercomputertomographieinderpraoperativendiagnostikderotosklerose AT lehnickdirk stellenwertdercomputertomographieinderpraoperativendiagnostikderotosklerose AT treumannthomas stellenwertdercomputertomographieinderpraoperativendiagnostikderotosklerose AT linderthomas stellenwertdercomputertomographieinderpraoperativendiagnostikderotosklerose |