Cargando…
Do Different Approaches Make a Difference in Isokinetic Performance in Elderly Patients With Femoral Neck Fracture Who Underwent Bipolar Endoprosthesis?
Background There are ongoing doubts about the effects of the commonly used anterolateral approach (ALA) and posterolateral approach (PLA) for bipolar hemiarthroplasty (BHA) on hip muscle strength after surgery. In this study, it was aimed to evaluate the isokinetic performance of the operated and no...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Cureus
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9897598/ https://www.ncbi.nlm.nih.gov/pubmed/36751156 http://dx.doi.org/10.7759/cureus.33362 |
_version_ | 1784882283876974592 |
---|---|
author | Korkmaz, İzzet Korkmaz, Nurdan Koç, Saadet S Bingöl, Olgun Kılıç, Enver Ozdemir, Guzelali Toğral, Güray |
author_facet | Korkmaz, İzzet Korkmaz, Nurdan Koç, Saadet S Bingöl, Olgun Kılıç, Enver Ozdemir, Guzelali Toğral, Güray |
author_sort | Korkmaz, İzzet |
collection | PubMed |
description | Background There are ongoing doubts about the effects of the commonly used anterolateral approach (ALA) and posterolateral approach (PLA) for bipolar hemiarthroplasty (BHA) on hip muscle strength after surgery. In this study, it was aimed to evaluate the isokinetic performance of the operated and non-operated hips in patients with femoral neck fractures who underwent BHA with PLA or ALA and to compare the isokinetic performance of the hips and functional results between the two approaches. Materials and methods Forty-one patients who underwent unilateral BHA with PLA or ALA for femoral neck fracture between February 2019 and December 2020 were enrolled. The isokinetic performance of the flexor, extensor, and abductor muscles of the operated and non-operated hips were evaluated by measuring peak torque, total work, and average power. Functional status was assessed using Harris Hip Score and Short Form 36. Results The patients were divided into two groups; those operated with PLA (n=22) and with ALA (n=19). The groups had similar demographic and clinical characteristics. All isokinetic parameters of the operated hips did not differ between the groups (all p>0.05). In both groups, all isokinetic parameters were significantly lower in the operated hips than in the non-operated hips. Conclusion Although there are debates about potential extensor muscle injury with PLA and potential abductor muscle injury with ALA, this study showed that functional results and the isokinetic performance of both approaches were not different. |
format | Online Article Text |
id | pubmed-9897598 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Cureus |
record_format | MEDLINE/PubMed |
spelling | pubmed-98975982023-02-06 Do Different Approaches Make a Difference in Isokinetic Performance in Elderly Patients With Femoral Neck Fracture Who Underwent Bipolar Endoprosthesis? Korkmaz, İzzet Korkmaz, Nurdan Koç, Saadet S Bingöl, Olgun Kılıç, Enver Ozdemir, Guzelali Toğral, Güray Cureus Orthopedics Background There are ongoing doubts about the effects of the commonly used anterolateral approach (ALA) and posterolateral approach (PLA) for bipolar hemiarthroplasty (BHA) on hip muscle strength after surgery. In this study, it was aimed to evaluate the isokinetic performance of the operated and non-operated hips in patients with femoral neck fractures who underwent BHA with PLA or ALA and to compare the isokinetic performance of the hips and functional results between the two approaches. Materials and methods Forty-one patients who underwent unilateral BHA with PLA or ALA for femoral neck fracture between February 2019 and December 2020 were enrolled. The isokinetic performance of the flexor, extensor, and abductor muscles of the operated and non-operated hips were evaluated by measuring peak torque, total work, and average power. Functional status was assessed using Harris Hip Score and Short Form 36. Results The patients were divided into two groups; those operated with PLA (n=22) and with ALA (n=19). The groups had similar demographic and clinical characteristics. All isokinetic parameters of the operated hips did not differ between the groups (all p>0.05). In both groups, all isokinetic parameters were significantly lower in the operated hips than in the non-operated hips. Conclusion Although there are debates about potential extensor muscle injury with PLA and potential abductor muscle injury with ALA, this study showed that functional results and the isokinetic performance of both approaches were not different. Cureus 2023-01-04 /pmc/articles/PMC9897598/ /pubmed/36751156 http://dx.doi.org/10.7759/cureus.33362 Text en Copyright © 2023, Korkmaz et al. https://creativecommons.org/licenses/by/3.0/This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. |
spellingShingle | Orthopedics Korkmaz, İzzet Korkmaz, Nurdan Koç, Saadet S Bingöl, Olgun Kılıç, Enver Ozdemir, Guzelali Toğral, Güray Do Different Approaches Make a Difference in Isokinetic Performance in Elderly Patients With Femoral Neck Fracture Who Underwent Bipolar Endoprosthesis? |
title | Do Different Approaches Make a Difference in Isokinetic Performance in Elderly Patients With Femoral Neck Fracture Who Underwent Bipolar Endoprosthesis? |
title_full | Do Different Approaches Make a Difference in Isokinetic Performance in Elderly Patients With Femoral Neck Fracture Who Underwent Bipolar Endoprosthesis? |
title_fullStr | Do Different Approaches Make a Difference in Isokinetic Performance in Elderly Patients With Femoral Neck Fracture Who Underwent Bipolar Endoprosthesis? |
title_full_unstemmed | Do Different Approaches Make a Difference in Isokinetic Performance in Elderly Patients With Femoral Neck Fracture Who Underwent Bipolar Endoprosthesis? |
title_short | Do Different Approaches Make a Difference in Isokinetic Performance in Elderly Patients With Femoral Neck Fracture Who Underwent Bipolar Endoprosthesis? |
title_sort | do different approaches make a difference in isokinetic performance in elderly patients with femoral neck fracture who underwent bipolar endoprosthesis? |
topic | Orthopedics |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9897598/ https://www.ncbi.nlm.nih.gov/pubmed/36751156 http://dx.doi.org/10.7759/cureus.33362 |
work_keys_str_mv | AT korkmazizzet dodifferentapproachesmakeadifferenceinisokineticperformanceinelderlypatientswithfemoralneckfracturewhounderwentbipolarendoprosthesis AT korkmaznurdan dodifferentapproachesmakeadifferenceinisokineticperformanceinelderlypatientswithfemoralneckfracturewhounderwentbipolarendoprosthesis AT kocsaadets dodifferentapproachesmakeadifferenceinisokineticperformanceinelderlypatientswithfemoralneckfracturewhounderwentbipolarendoprosthesis AT bingololgun dodifferentapproachesmakeadifferenceinisokineticperformanceinelderlypatientswithfemoralneckfracturewhounderwentbipolarendoprosthesis AT kılıcenver dodifferentapproachesmakeadifferenceinisokineticperformanceinelderlypatientswithfemoralneckfracturewhounderwentbipolarendoprosthesis AT ozdemirguzelali dodifferentapproachesmakeadifferenceinisokineticperformanceinelderlypatientswithfemoralneckfracturewhounderwentbipolarendoprosthesis AT togralguray dodifferentapproachesmakeadifferenceinisokineticperformanceinelderlypatientswithfemoralneckfracturewhounderwentbipolarendoprosthesis |