Cargando…

Aorto-cutaneous fistula of the ascending aorta—case report and a literature review of endovascular management

Aorto-cutaneous fistulas are an unusual and life-threatening complication after aortic surgery. We present the case of an endovascular intervention for an aorto-cutaneous fistula of the ascending aorta that was intended to be a bridge to definitive surgical treatment and report a literature review....

Descripción completa

Detalles Bibliográficos
Autores principales: Gormley, Sinead, Zaman, Zubayr, Mani, Kevin, Khashram, Manar
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9898732/
https://www.ncbi.nlm.nih.gov/pubmed/36747605
http://dx.doi.org/10.1016/j.jvscit.2022.06.023
_version_ 1784882490867974144
author Gormley, Sinead
Zaman, Zubayr
Mani, Kevin
Khashram, Manar
author_facet Gormley, Sinead
Zaman, Zubayr
Mani, Kevin
Khashram, Manar
author_sort Gormley, Sinead
collection PubMed
description Aorto-cutaneous fistulas are an unusual and life-threatening complication after aortic surgery. We present the case of an endovascular intervention for an aorto-cutaneous fistula of the ascending aorta that was intended to be a bridge to definitive surgical treatment and report a literature review. A 56-year-old woman had a previous Bentall’s procedure and mitral valve annuloplasty in 2016. Four years later she re-presented with an infective pseudoaneurysm of the distal anastomosis of the ascending aortic graft, with aorto-cutaneous fistulation. She was at high risk for a revision operation and required optimization before a major open surgery. A thoracic endovascular aortic repair stent graft (Valiant Navion; Medtronic Inc) was implanted to exclude the distal anastomotic pseudoaneurysm. Two months later she re-presented with a new infected pseudoaneurysm at the proximal end of the previously implanted stent graft, and a further thoracic endovascular aortic repair was undertaken.
format Online
Article
Text
id pubmed-9898732
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-98987322023-02-05 Aorto-cutaneous fistula of the ascending aorta—case report and a literature review of endovascular management Gormley, Sinead Zaman, Zubayr Mani, Kevin Khashram, Manar J Vasc Surg Cases Innov Tech Case report Aorto-cutaneous fistulas are an unusual and life-threatening complication after aortic surgery. We present the case of an endovascular intervention for an aorto-cutaneous fistula of the ascending aorta that was intended to be a bridge to definitive surgical treatment and report a literature review. A 56-year-old woman had a previous Bentall’s procedure and mitral valve annuloplasty in 2016. Four years later she re-presented with an infective pseudoaneurysm of the distal anastomosis of the ascending aortic graft, with aorto-cutaneous fistulation. She was at high risk for a revision operation and required optimization before a major open surgery. A thoracic endovascular aortic repair stent graft (Valiant Navion; Medtronic Inc) was implanted to exclude the distal anastomotic pseudoaneurysm. Two months later she re-presented with a new infected pseudoaneurysm at the proximal end of the previously implanted stent graft, and a further thoracic endovascular aortic repair was undertaken. Elsevier 2022-07-30 /pmc/articles/PMC9898732/ /pubmed/36747605 http://dx.doi.org/10.1016/j.jvscit.2022.06.023 Text en © 2022 The Author(s) https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Case report
Gormley, Sinead
Zaman, Zubayr
Mani, Kevin
Khashram, Manar
Aorto-cutaneous fistula of the ascending aorta—case report and a literature review of endovascular management
title Aorto-cutaneous fistula of the ascending aorta—case report and a literature review of endovascular management
title_full Aorto-cutaneous fistula of the ascending aorta—case report and a literature review of endovascular management
title_fullStr Aorto-cutaneous fistula of the ascending aorta—case report and a literature review of endovascular management
title_full_unstemmed Aorto-cutaneous fistula of the ascending aorta—case report and a literature review of endovascular management
title_short Aorto-cutaneous fistula of the ascending aorta—case report and a literature review of endovascular management
title_sort aorto-cutaneous fistula of the ascending aorta—case report and a literature review of endovascular management
topic Case report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9898732/
https://www.ncbi.nlm.nih.gov/pubmed/36747605
http://dx.doi.org/10.1016/j.jvscit.2022.06.023
work_keys_str_mv AT gormleysinead aortocutaneousfistulaoftheascendingaortacasereportandaliteraturereviewofendovascularmanagement
AT zamanzubayr aortocutaneousfistulaoftheascendingaortacasereportandaliteraturereviewofendovascularmanagement
AT manikevin aortocutaneousfistulaoftheascendingaortacasereportandaliteraturereviewofendovascularmanagement
AT khashrammanar aortocutaneousfistulaoftheascendingaortacasereportandaliteraturereviewofendovascularmanagement