Cargando…
Accuracy of high definition near infrared transillumination camera in detection of hidden proximal caries
BACKGROUND: Early caries detection became mandatory in modern dentistry. However, the traditional methods in caries detection had many limitations. Hence,a novel approach based on Near Infrared technology was introduced to overcome such limitations. MATERIAL AND METHODS: Proximal surfaces of 102 pos...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Medicina Oral S.L.
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9899360/ https://www.ncbi.nlm.nih.gov/pubmed/36755680 http://dx.doi.org/10.4317/jced.59413 |
_version_ | 1784882620953264128 |
---|---|
author | Edrees, Amr Hassanein, Olfat Shaalan, Omar Yassen, Asmaa |
author_facet | Edrees, Amr Hassanein, Olfat Shaalan, Omar Yassen, Asmaa |
author_sort | Edrees, Amr |
collection | PubMed |
description | BACKGROUND: Early caries detection became mandatory in modern dentistry. However, the traditional methods in caries detection had many limitations. Hence,a novel approach based on Near Infrared technology was introduced to overcome such limitations. MATERIAL AND METHODS: Proximal surfaces of 102 posterior teeth from 36 adult participants who fulfilled the eligibility criteria were assessed by two examiners using three diagnostic methods. Teeth were examined visually according to the criteria of the International Caries Detection and Assessment System (ICDAS-II) then examined by bitewing digital radiograph (BW) and near infrared light transillumination (NIRT) camera (Vista Proxi iX HD smart). Inter and intra observer agreements were assessed using Kappa test.Dignostic accuracy parameters and Area Under the ROC curve (AUROC) with 95% confidence interval (95% CI) were evaluated for the different caries assessment methods. RESULTS: The results of inter-observer agreement showed an excellent agreement in the different groups. There was a statistically significant difference in the score distribution between ICDASII and VistaCam modalities (P-value <0.05). While there was no statistically significant difference in the score distribution between bitewing radiography and VistaCam modalities (P-value >0.05). ROC curve analysis revealed that VistaCam when compared with ICDASII had sensitivity (99.0%), specificity (50.0 %), diagnostic accuracy (98.0%) and Area under the ROC curve (AUC) was 0.745 with 95% Confidence Interval (0.649 – 0.826).When VistaCam compared with bitewing radiography, it showed sensitivity (100.0%); specificity (40.0%), diagnostic accuracy (97.1%) and AUC (0.700) with 95% confidence interval (0.601 – 0.787). CONCLUSIONS: NIRT based diagnostic modality is a promising method for detection of hidden proximal lesions overcoming the hazards of radiograph. Key words:Bitewing radiography , ICDAS II , Near-infrared transillumination, proximal caries, VistaCam® iX Proxi. |
format | Online Article Text |
id | pubmed-9899360 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Medicina Oral S.L. |
record_format | MEDLINE/PubMed |
spelling | pubmed-98993602023-02-07 Accuracy of high definition near infrared transillumination camera in detection of hidden proximal caries Edrees, Amr Hassanein, Olfat Shaalan, Omar Yassen, Asmaa J Clin Exp Dent Research BACKGROUND: Early caries detection became mandatory in modern dentistry. However, the traditional methods in caries detection had many limitations. Hence,a novel approach based on Near Infrared technology was introduced to overcome such limitations. MATERIAL AND METHODS: Proximal surfaces of 102 posterior teeth from 36 adult participants who fulfilled the eligibility criteria were assessed by two examiners using three diagnostic methods. Teeth were examined visually according to the criteria of the International Caries Detection and Assessment System (ICDAS-II) then examined by bitewing digital radiograph (BW) and near infrared light transillumination (NIRT) camera (Vista Proxi iX HD smart). Inter and intra observer agreements were assessed using Kappa test.Dignostic accuracy parameters and Area Under the ROC curve (AUROC) with 95% confidence interval (95% CI) were evaluated for the different caries assessment methods. RESULTS: The results of inter-observer agreement showed an excellent agreement in the different groups. There was a statistically significant difference in the score distribution between ICDASII and VistaCam modalities (P-value <0.05). While there was no statistically significant difference in the score distribution between bitewing radiography and VistaCam modalities (P-value >0.05). ROC curve analysis revealed that VistaCam when compared with ICDASII had sensitivity (99.0%), specificity (50.0 %), diagnostic accuracy (98.0%) and Area under the ROC curve (AUC) was 0.745 with 95% Confidence Interval (0.649 – 0.826).When VistaCam compared with bitewing radiography, it showed sensitivity (100.0%); specificity (40.0%), diagnostic accuracy (97.1%) and AUC (0.700) with 95% confidence interval (0.601 – 0.787). CONCLUSIONS: NIRT based diagnostic modality is a promising method for detection of hidden proximal lesions overcoming the hazards of radiograph. Key words:Bitewing radiography , ICDAS II , Near-infrared transillumination, proximal caries, VistaCam® iX Proxi. Medicina Oral S.L. 2023-01-01 /pmc/articles/PMC9899360/ /pubmed/36755680 http://dx.doi.org/10.4317/jced.59413 Text en Copyright: © 2023 Medicina Oral S.L. https://creativecommons.org/licenses/by/2.5/This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Edrees, Amr Hassanein, Olfat Shaalan, Omar Yassen, Asmaa Accuracy of high definition near infrared transillumination camera in detection of hidden proximal caries |
title | Accuracy of high definition near infrared transillumination camera in detection of hidden proximal caries |
title_full | Accuracy of high definition near infrared transillumination camera in detection of hidden proximal caries |
title_fullStr | Accuracy of high definition near infrared transillumination camera in detection of hidden proximal caries |
title_full_unstemmed | Accuracy of high definition near infrared transillumination camera in detection of hidden proximal caries |
title_short | Accuracy of high definition near infrared transillumination camera in detection of hidden proximal caries |
title_sort | accuracy of high definition near infrared transillumination camera in detection of hidden proximal caries |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9899360/ https://www.ncbi.nlm.nih.gov/pubmed/36755680 http://dx.doi.org/10.4317/jced.59413 |
work_keys_str_mv | AT edreesamr accuracyofhighdefinitionnearinfraredtransilluminationcameraindetectionofhiddenproximalcaries AT hassaneinolfat accuracyofhighdefinitionnearinfraredtransilluminationcameraindetectionofhiddenproximalcaries AT shaalanomar accuracyofhighdefinitionnearinfraredtransilluminationcameraindetectionofhiddenproximalcaries AT yassenasmaa accuracyofhighdefinitionnearinfraredtransilluminationcameraindetectionofhiddenproximalcaries |