Cargando…
Diameter and taper variability of gutta-percha cones adapted to TruNatomyTM and RotateTM rotary file systems
BACKGROUND: Evaluate the discrepancy in diameter and taper between adapted gutta-percha cones for TruNatomyTM 26.04 (TRU04), RotateTM 25.04 (ROT04) and 25.06 (ROT06) systems and their reference files. MATERIAL AND METHODS: A sample of 60 gutta-percha cones and 15 rotary files was selected and divide...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Medicina Oral S.L.
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9899363/ https://www.ncbi.nlm.nih.gov/pubmed/36755679 http://dx.doi.org/10.4317/jced.59992 |
_version_ | 1784882621678878720 |
---|---|
author | Martínez, Ignacio Lozano, Adrián Sanz, José-Luis Forner, Leopoldo Llena, Carmen |
author_facet | Martínez, Ignacio Lozano, Adrián Sanz, José-Luis Forner, Leopoldo Llena, Carmen |
author_sort | Martínez, Ignacio |
collection | PubMed |
description | BACKGROUND: Evaluate the discrepancy in diameter and taper between adapted gutta-percha cones for TruNatomyTM 26.04 (TRU04), RotateTM 25.04 (ROT04) and 25.06 (ROT06) systems and their reference files. MATERIAL AND METHODS: A sample of 60 gutta-percha cones and 15 rotary files was selected and divided into three groups (TRU04, ROT04, ROT06). Each group consisted of 20 cones and 5 corresponding files. They were observed under an optical microscope at x20 magnification and images of all observations were obtained. Diameters were measured with a digital ruler calibrated at 3 levels: D1, D3, D16 (mm from tip). The taper of each system of cones and files was calculated, The percentage of discrepancy between the taper of each file system and its corresponding gutta-percha cone was calculated. RESULTS: The percentage of discrepancy between the diameter of the tested gutta-percha cones and their corresponding files varied from -7% to 21%. The smallest dimensional discrepancy between gutta-percha cone and corresponding file was found at D16 in TRU04 group. The tapers of the gutta-percha cones vs their respective files were: 2% vs 3% (TRU04), 4% vs 5% (ROT04), and 6% vs 5% (ROT06). The highest discrepancy was observed at D16 in ROT06 group. The global taper discrepancy between gutta-percha cone and its corresponding file was negative in TRU04 and ROT04 groups. CONCLUSIONS: The taper and the diameter at D1, D3, and D16 differed between all of the tested gutta-percha cones and their corresponding files. TruNatomy 26.04 files and its adapted gutta-percha cones exhibited the least discrepancy. Key words:Corresponding gutta-percha, rotary file, taper, TruNatomy, Rotate, standardization. |
format | Online Article Text |
id | pubmed-9899363 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Medicina Oral S.L. |
record_format | MEDLINE/PubMed |
spelling | pubmed-98993632023-02-07 Diameter and taper variability of gutta-percha cones adapted to TruNatomyTM and RotateTM rotary file systems Martínez, Ignacio Lozano, Adrián Sanz, José-Luis Forner, Leopoldo Llena, Carmen J Clin Exp Dent Research BACKGROUND: Evaluate the discrepancy in diameter and taper between adapted gutta-percha cones for TruNatomyTM 26.04 (TRU04), RotateTM 25.04 (ROT04) and 25.06 (ROT06) systems and their reference files. MATERIAL AND METHODS: A sample of 60 gutta-percha cones and 15 rotary files was selected and divided into three groups (TRU04, ROT04, ROT06). Each group consisted of 20 cones and 5 corresponding files. They were observed under an optical microscope at x20 magnification and images of all observations were obtained. Diameters were measured with a digital ruler calibrated at 3 levels: D1, D3, D16 (mm from tip). The taper of each system of cones and files was calculated, The percentage of discrepancy between the taper of each file system and its corresponding gutta-percha cone was calculated. RESULTS: The percentage of discrepancy between the diameter of the tested gutta-percha cones and their corresponding files varied from -7% to 21%. The smallest dimensional discrepancy between gutta-percha cone and corresponding file was found at D16 in TRU04 group. The tapers of the gutta-percha cones vs their respective files were: 2% vs 3% (TRU04), 4% vs 5% (ROT04), and 6% vs 5% (ROT06). The highest discrepancy was observed at D16 in ROT06 group. The global taper discrepancy between gutta-percha cone and its corresponding file was negative in TRU04 and ROT04 groups. CONCLUSIONS: The taper and the diameter at D1, D3, and D16 differed between all of the tested gutta-percha cones and their corresponding files. TruNatomy 26.04 files and its adapted gutta-percha cones exhibited the least discrepancy. Key words:Corresponding gutta-percha, rotary file, taper, TruNatomy, Rotate, standardization. Medicina Oral S.L. 2023-01-01 /pmc/articles/PMC9899363/ /pubmed/36755679 http://dx.doi.org/10.4317/jced.59992 Text en Copyright: © 2023 Medicina Oral S.L. https://creativecommons.org/licenses/by/2.5/This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Martínez, Ignacio Lozano, Adrián Sanz, José-Luis Forner, Leopoldo Llena, Carmen Diameter and taper variability of gutta-percha cones adapted to TruNatomyTM and RotateTM rotary file systems |
title | Diameter and taper variability of gutta-percha cones adapted to TruNatomyTM and RotateTM rotary file systems |
title_full | Diameter and taper variability of gutta-percha cones adapted to TruNatomyTM and RotateTM rotary file systems |
title_fullStr | Diameter and taper variability of gutta-percha cones adapted to TruNatomyTM and RotateTM rotary file systems |
title_full_unstemmed | Diameter and taper variability of gutta-percha cones adapted to TruNatomyTM and RotateTM rotary file systems |
title_short | Diameter and taper variability of gutta-percha cones adapted to TruNatomyTM and RotateTM rotary file systems |
title_sort | diameter and taper variability of gutta-percha cones adapted to trunatomytm and rotatetm rotary file systems |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9899363/ https://www.ncbi.nlm.nih.gov/pubmed/36755679 http://dx.doi.org/10.4317/jced.59992 |
work_keys_str_mv | AT martinezignacio diameterandtapervariabilityofguttaperchaconesadaptedtotrunatomytmandrotatetmrotaryfilesystems AT lozanoadrian diameterandtapervariabilityofguttaperchaconesadaptedtotrunatomytmandrotatetmrotaryfilesystems AT sanzjoseluis diameterandtapervariabilityofguttaperchaconesadaptedtotrunatomytmandrotatetmrotaryfilesystems AT fornerleopoldo diameterandtapervariabilityofguttaperchaconesadaptedtotrunatomytmandrotatetmrotaryfilesystems AT llenacarmen diameterandtapervariabilityofguttaperchaconesadaptedtotrunatomytmandrotatetmrotaryfilesystems |