Cargando…

Diameter and taper variability of gutta-percha cones adapted to TruNatomyTM and RotateTM rotary file systems

BACKGROUND: Evaluate the discrepancy in diameter and taper between adapted gutta-percha cones for TruNatomyTM 26.04 (TRU04), RotateTM 25.04 (ROT04) and 25.06 (ROT06) systems and their reference files. MATERIAL AND METHODS: A sample of 60 gutta-percha cones and 15 rotary files was selected and divide...

Descripción completa

Detalles Bibliográficos
Autores principales: Martínez, Ignacio, Lozano, Adrián, Sanz, José-Luis, Forner, Leopoldo, Llena, Carmen
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medicina Oral S.L. 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9899363/
https://www.ncbi.nlm.nih.gov/pubmed/36755679
http://dx.doi.org/10.4317/jced.59992
_version_ 1784882621678878720
author Martínez, Ignacio
Lozano, Adrián
Sanz, José-Luis
Forner, Leopoldo
Llena, Carmen
author_facet Martínez, Ignacio
Lozano, Adrián
Sanz, José-Luis
Forner, Leopoldo
Llena, Carmen
author_sort Martínez, Ignacio
collection PubMed
description BACKGROUND: Evaluate the discrepancy in diameter and taper between adapted gutta-percha cones for TruNatomyTM 26.04 (TRU04), RotateTM 25.04 (ROT04) and 25.06 (ROT06) systems and their reference files. MATERIAL AND METHODS: A sample of 60 gutta-percha cones and 15 rotary files was selected and divided into three groups (TRU04, ROT04, ROT06). Each group consisted of 20 cones and 5 corresponding files. They were observed under an optical microscope at x20 magnification and images of all observations were obtained. Diameters were measured with a digital ruler calibrated at 3 levels: D1, D3, D16 (mm from tip). The taper of each system of cones and files was calculated, The percentage of discrepancy between the taper of each file system and its corresponding gutta-percha cone was calculated. RESULTS: The percentage of discrepancy between the diameter of the tested gutta-percha cones and their corresponding files varied from -7% to 21%. The smallest dimensional discrepancy between gutta-percha cone and corresponding file was found at D16 in TRU04 group. The tapers of the gutta-percha cones vs their respective files were: 2% vs 3% (TRU04), 4% vs 5% (ROT04), and 6% vs 5% (ROT06). The highest discrepancy was observed at D16 in ROT06 group. The global taper discrepancy between gutta-percha cone and its corresponding file was negative in TRU04 and ROT04 groups. CONCLUSIONS: The taper and the diameter at D1, D3, and D16 differed between all of the tested gutta-percha cones and their corresponding files. TruNatomy 26.04 files and its adapted gutta-percha cones exhibited the least discrepancy. Key words:Corresponding gutta-percha, rotary file, taper, TruNatomy, Rotate, standardization.
format Online
Article
Text
id pubmed-9899363
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Medicina Oral S.L.
record_format MEDLINE/PubMed
spelling pubmed-98993632023-02-07 Diameter and taper variability of gutta-percha cones adapted to TruNatomyTM and RotateTM rotary file systems Martínez, Ignacio Lozano, Adrián Sanz, José-Luis Forner, Leopoldo Llena, Carmen J Clin Exp Dent Research BACKGROUND: Evaluate the discrepancy in diameter and taper between adapted gutta-percha cones for TruNatomyTM 26.04 (TRU04), RotateTM 25.04 (ROT04) and 25.06 (ROT06) systems and their reference files. MATERIAL AND METHODS: A sample of 60 gutta-percha cones and 15 rotary files was selected and divided into three groups (TRU04, ROT04, ROT06). Each group consisted of 20 cones and 5 corresponding files. They were observed under an optical microscope at x20 magnification and images of all observations were obtained. Diameters were measured with a digital ruler calibrated at 3 levels: D1, D3, D16 (mm from tip). The taper of each system of cones and files was calculated, The percentage of discrepancy between the taper of each file system and its corresponding gutta-percha cone was calculated. RESULTS: The percentage of discrepancy between the diameter of the tested gutta-percha cones and their corresponding files varied from -7% to 21%. The smallest dimensional discrepancy between gutta-percha cone and corresponding file was found at D16 in TRU04 group. The tapers of the gutta-percha cones vs their respective files were: 2% vs 3% (TRU04), 4% vs 5% (ROT04), and 6% vs 5% (ROT06). The highest discrepancy was observed at D16 in ROT06 group. The global taper discrepancy between gutta-percha cone and its corresponding file was negative in TRU04 and ROT04 groups. CONCLUSIONS: The taper and the diameter at D1, D3, and D16 differed between all of the tested gutta-percha cones and their corresponding files. TruNatomy 26.04 files and its adapted gutta-percha cones exhibited the least discrepancy. Key words:Corresponding gutta-percha, rotary file, taper, TruNatomy, Rotate, standardization. Medicina Oral S.L. 2023-01-01 /pmc/articles/PMC9899363/ /pubmed/36755679 http://dx.doi.org/10.4317/jced.59992 Text en Copyright: © 2023 Medicina Oral S.L. https://creativecommons.org/licenses/by/2.5/This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research
Martínez, Ignacio
Lozano, Adrián
Sanz, José-Luis
Forner, Leopoldo
Llena, Carmen
Diameter and taper variability of gutta-percha cones adapted to TruNatomyTM and RotateTM rotary file systems
title Diameter and taper variability of gutta-percha cones adapted to TruNatomyTM and RotateTM rotary file systems
title_full Diameter and taper variability of gutta-percha cones adapted to TruNatomyTM and RotateTM rotary file systems
title_fullStr Diameter and taper variability of gutta-percha cones adapted to TruNatomyTM and RotateTM rotary file systems
title_full_unstemmed Diameter and taper variability of gutta-percha cones adapted to TruNatomyTM and RotateTM rotary file systems
title_short Diameter and taper variability of gutta-percha cones adapted to TruNatomyTM and RotateTM rotary file systems
title_sort diameter and taper variability of gutta-percha cones adapted to trunatomytm and rotatetm rotary file systems
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9899363/
https://www.ncbi.nlm.nih.gov/pubmed/36755679
http://dx.doi.org/10.4317/jced.59992
work_keys_str_mv AT martinezignacio diameterandtapervariabilityofguttaperchaconesadaptedtotrunatomytmandrotatetmrotaryfilesystems
AT lozanoadrian diameterandtapervariabilityofguttaperchaconesadaptedtotrunatomytmandrotatetmrotaryfilesystems
AT sanzjoseluis diameterandtapervariabilityofguttaperchaconesadaptedtotrunatomytmandrotatetmrotaryfilesystems
AT fornerleopoldo diameterandtapervariabilityofguttaperchaconesadaptedtotrunatomytmandrotatetmrotaryfilesystems
AT llenacarmen diameterandtapervariabilityofguttaperchaconesadaptedtotrunatomytmandrotatetmrotaryfilesystems