Cargando…
Reproducibility of the energy metabolism response to an oral glucose tolerance test: influence of a postcalorimetric correction procedure
PURPOSE: Metabolic flexibility (MetF), which is a surrogate of metabolic health, can be assessed by the change in the respiratory exchange ratio (RER) in response to an oral glucose tolerance test (OGTT). We aimed to determine the day-to-day reproducibility of the energy expenditure (EE) and RER res...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer Berlin Heidelberg
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9899729/ https://www.ncbi.nlm.nih.gov/pubmed/36006468 http://dx.doi.org/10.1007/s00394-022-02986-w |
Sumario: | PURPOSE: Metabolic flexibility (MetF), which is a surrogate of metabolic health, can be assessed by the change in the respiratory exchange ratio (RER) in response to an oral glucose tolerance test (OGTT). We aimed to determine the day-to-day reproducibility of the energy expenditure (EE) and RER response to an OGTT, and whether a simulation-based postcalorimetric correction of metabolic cart readouts improves day-to-day reproducibility. METHODS: The EE was assessed (12 young adults, 6 women, 27 ± 2 years old) using an Omnical metabolic cart (Maastricht Instruments, Maastricht, The Netherlands) after an overnight fast (12 h) and after a 75-g oral glucose dose on 2 separate days (48 h). On both days, we assessed EE in 7 periods (one 30-min baseline and six 15-min postprandial). The ICcE was performed immediately after each recording period, and capillary glucose concentration (using a digital glucometer) was determined. RESULTS: We observed a high day-to-day reproducibility for the assessed RER (coefficients of variation [CV] < 4%) and EE (CVs < 9%) in the 7 different periods. In contrast, the RER and EE areas under the curve showed a low day-to-day reproducibility (CV = 22% and 56%, respectively). Contrary to our expectations, the postcalorimetric correction procedure did not influence the day-to-day reproducibility of the energy metabolism response, possibly because the Omnical’s accuracy was ~ 100%. CONCLUSION: Our study demonstrates that the energy metabolism response to an OGTT is poorly reproducible (CVs > 20%) even using a very accurate metabolic cart. Furthermore, the postcalorimetric correction procedure did not influence the day-to-day reproducibility. Trial registration NCT04320433; March 25, 2020. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s00394-022-02986-w. |
---|