Cargando…

Evaluating the “wrong-way-round” electrospray ionization of antiretroviral drugs for improved detection sensitivity

The presence of antiretroviral drugs (ARVDs) in the aquatic environment poses a significant health risk to the ecosystem. The dilution of these compounds during wastewater treatment processes, followed by discharge into the environment, results in extremely low concentrations in the range of ng/L. T...

Descripción completa

Detalles Bibliográficos
Autores principales: Venter, Pieter, van Onselen, Rianita
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Berlin Heidelberg 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9899738/
https://www.ncbi.nlm.nih.gov/pubmed/36637494
http://dx.doi.org/10.1007/s00216-022-04499-1
_version_ 1784882695271088128
author Venter, Pieter
van Onselen, Rianita
author_facet Venter, Pieter
van Onselen, Rianita
author_sort Venter, Pieter
collection PubMed
description The presence of antiretroviral drugs (ARVDs) in the aquatic environment poses a significant health risk to the ecosystem. The dilution of these compounds during wastewater treatment processes, followed by discharge into the environment, results in extremely low concentrations in the range of ng/L. Therefore, to enable detection of these low concentrations, it is important to determine the most efficient electrospray ionization (ESI) mode using the right mobile phase modifier and to establish a selective extraction procedure. In this study, we compared the ESI intensity in the positive and negative mode using both formic acid (FA) and ammonium hydroxide (NH(4)OH) as mobile phase modifiers. The results revealed a phenomenon known as the “wrong-way-round” (WWR) ESI in which high intensity [M + H](+) ions were detected under basic conditions using NH(4)OH as modifier and, similarly, high intensity [M-H](−) ions were detected under acidic conditions using FA as modifier. Furthermore, mixed-mode strong cation (MCX) and mixed-mode strong anion (MAX) exchange sorbents were evaluated for extraction recoveries, which yielded extraction recoveries between 60 and 100%. Finally, the recoveries obtained using mixed-mode ion exchange sorbents compared to ion production during the ESI process provide evidence that ions produced in solution do not necessarily reflect the ions that are produced during the ESI process. Based on the results of this study, it is recommended to evaluate the optimal ionization mode under basic and acidic conditions, instead of defaulting to the use of acidic modifiers with positive ion detection. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s00216-022-04499-1.
format Online
Article
Text
id pubmed-9899738
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Springer Berlin Heidelberg
record_format MEDLINE/PubMed
spelling pubmed-98997382023-02-07 Evaluating the “wrong-way-round” electrospray ionization of antiretroviral drugs for improved detection sensitivity Venter, Pieter van Onselen, Rianita Anal Bioanal Chem Research Paper The presence of antiretroviral drugs (ARVDs) in the aquatic environment poses a significant health risk to the ecosystem. The dilution of these compounds during wastewater treatment processes, followed by discharge into the environment, results in extremely low concentrations in the range of ng/L. Therefore, to enable detection of these low concentrations, it is important to determine the most efficient electrospray ionization (ESI) mode using the right mobile phase modifier and to establish a selective extraction procedure. In this study, we compared the ESI intensity in the positive and negative mode using both formic acid (FA) and ammonium hydroxide (NH(4)OH) as mobile phase modifiers. The results revealed a phenomenon known as the “wrong-way-round” (WWR) ESI in which high intensity [M + H](+) ions were detected under basic conditions using NH(4)OH as modifier and, similarly, high intensity [M-H](−) ions were detected under acidic conditions using FA as modifier. Furthermore, mixed-mode strong cation (MCX) and mixed-mode strong anion (MAX) exchange sorbents were evaluated for extraction recoveries, which yielded extraction recoveries between 60 and 100%. Finally, the recoveries obtained using mixed-mode ion exchange sorbents compared to ion production during the ESI process provide evidence that ions produced in solution do not necessarily reflect the ions that are produced during the ESI process. Based on the results of this study, it is recommended to evaluate the optimal ionization mode under basic and acidic conditions, instead of defaulting to the use of acidic modifiers with positive ion detection. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s00216-022-04499-1. Springer Berlin Heidelberg 2023-01-13 2023 /pmc/articles/PMC9899738/ /pubmed/36637494 http://dx.doi.org/10.1007/s00216-022-04499-1 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Research Paper
Venter, Pieter
van Onselen, Rianita
Evaluating the “wrong-way-round” electrospray ionization of antiretroviral drugs for improved detection sensitivity
title Evaluating the “wrong-way-round” electrospray ionization of antiretroviral drugs for improved detection sensitivity
title_full Evaluating the “wrong-way-round” electrospray ionization of antiretroviral drugs for improved detection sensitivity
title_fullStr Evaluating the “wrong-way-round” electrospray ionization of antiretroviral drugs for improved detection sensitivity
title_full_unstemmed Evaluating the “wrong-way-round” electrospray ionization of antiretroviral drugs for improved detection sensitivity
title_short Evaluating the “wrong-way-round” electrospray ionization of antiretroviral drugs for improved detection sensitivity
title_sort evaluating the “wrong-way-round” electrospray ionization of antiretroviral drugs for improved detection sensitivity
topic Research Paper
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9899738/
https://www.ncbi.nlm.nih.gov/pubmed/36637494
http://dx.doi.org/10.1007/s00216-022-04499-1
work_keys_str_mv AT venterpieter evaluatingthewrongwayroundelectrosprayionizationofantiretroviraldrugsforimproveddetectionsensitivity
AT vanonselenrianita evaluatingthewrongwayroundelectrosprayionizationofantiretroviraldrugsforimproveddetectionsensitivity