Cargando…
Differential diagnosis of gallbladder neoplastic polyps and cholesterol polyps with radiomics of dual modal ultrasound: a pilot study
PURPOSE: To verify whether radiomics techniques based on dual-modality ultrasound consisting of B-mode and superb microvascular imaging (SMI) can improve the accuracy of the differentiation between gallbladder neoplastic polyps and cholesterol polyps. METHODS: A total of 100 patients with 100 pathol...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9901123/ https://www.ncbi.nlm.nih.gov/pubmed/36747143 http://dx.doi.org/10.1186/s12880-023-00982-y |
_version_ | 1784882977550893056 |
---|---|
author | Yuan, Hai-xia Wang, Changyan Tang, Cong-yu You, Qi-qin Zhang, Qi Wang, Wen-ping |
author_facet | Yuan, Hai-xia Wang, Changyan Tang, Cong-yu You, Qi-qin Zhang, Qi Wang, Wen-ping |
author_sort | Yuan, Hai-xia |
collection | PubMed |
description | PURPOSE: To verify whether radiomics techniques based on dual-modality ultrasound consisting of B-mode and superb microvascular imaging (SMI) can improve the accuracy of the differentiation between gallbladder neoplastic polyps and cholesterol polyps. METHODS: A total of 100 patients with 100 pathologically proven gallbladder polypoid lesions were enrolled in this retrospective study. Radiomics features on B-mode ultrasound and SMI of each lesion were extracted. Support vector machine was used to classify adenomas and cholesterol polyps of gallbladder for B-mode, SMI and dual-modality ultrasound, respectively, and the classification results were compared among the three groups. RESULTS: Six, eight and nine features were extracted for each lesion at B-mode ultrasound, SMI and dual-modality ultrasound, respectively. In dual-modality ultrasound model, the area under the receiver operating characteristic curve (AUC), classification accuracy, sensitivity, specificity, and Youden’s index were 0.850 ± 0.090, 0.828 ± 0.097, 0.892 ± 0.144, 0.803 ± 0.149 and 0.695 ± 0.157, respectively. The AUC and Youden’s index of the dual-modality model were higher than those of the B-mode model (p < 0.05). The AUC, accuracy, specificity and Youden’s index of the dual-modality model were higher than those of the SMI model (p < 0.05). CONCLUSIONS: Radiomics analysis of the dual-modality ultrasound composed of B-mode and SMI can improve the accuracy of classification between gallbladder neoplastic polyps and cholesterol polyps. |
format | Online Article Text |
id | pubmed-9901123 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-99011232023-02-07 Differential diagnosis of gallbladder neoplastic polyps and cholesterol polyps with radiomics of dual modal ultrasound: a pilot study Yuan, Hai-xia Wang, Changyan Tang, Cong-yu You, Qi-qin Zhang, Qi Wang, Wen-ping BMC Med Imaging Research PURPOSE: To verify whether radiomics techniques based on dual-modality ultrasound consisting of B-mode and superb microvascular imaging (SMI) can improve the accuracy of the differentiation between gallbladder neoplastic polyps and cholesterol polyps. METHODS: A total of 100 patients with 100 pathologically proven gallbladder polypoid lesions were enrolled in this retrospective study. Radiomics features on B-mode ultrasound and SMI of each lesion were extracted. Support vector machine was used to classify adenomas and cholesterol polyps of gallbladder for B-mode, SMI and dual-modality ultrasound, respectively, and the classification results were compared among the three groups. RESULTS: Six, eight and nine features were extracted for each lesion at B-mode ultrasound, SMI and dual-modality ultrasound, respectively. In dual-modality ultrasound model, the area under the receiver operating characteristic curve (AUC), classification accuracy, sensitivity, specificity, and Youden’s index were 0.850 ± 0.090, 0.828 ± 0.097, 0.892 ± 0.144, 0.803 ± 0.149 and 0.695 ± 0.157, respectively. The AUC and Youden’s index of the dual-modality model were higher than those of the B-mode model (p < 0.05). The AUC, accuracy, specificity and Youden’s index of the dual-modality model were higher than those of the SMI model (p < 0.05). CONCLUSIONS: Radiomics analysis of the dual-modality ultrasound composed of B-mode and SMI can improve the accuracy of classification between gallbladder neoplastic polyps and cholesterol polyps. BioMed Central 2023-02-06 /pmc/articles/PMC9901123/ /pubmed/36747143 http://dx.doi.org/10.1186/s12880-023-00982-y Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Research Yuan, Hai-xia Wang, Changyan Tang, Cong-yu You, Qi-qin Zhang, Qi Wang, Wen-ping Differential diagnosis of gallbladder neoplastic polyps and cholesterol polyps with radiomics of dual modal ultrasound: a pilot study |
title | Differential diagnosis of gallbladder neoplastic polyps and cholesterol polyps with radiomics of dual modal ultrasound: a pilot study |
title_full | Differential diagnosis of gallbladder neoplastic polyps and cholesterol polyps with radiomics of dual modal ultrasound: a pilot study |
title_fullStr | Differential diagnosis of gallbladder neoplastic polyps and cholesterol polyps with radiomics of dual modal ultrasound: a pilot study |
title_full_unstemmed | Differential diagnosis of gallbladder neoplastic polyps and cholesterol polyps with radiomics of dual modal ultrasound: a pilot study |
title_short | Differential diagnosis of gallbladder neoplastic polyps and cholesterol polyps with radiomics of dual modal ultrasound: a pilot study |
title_sort | differential diagnosis of gallbladder neoplastic polyps and cholesterol polyps with radiomics of dual modal ultrasound: a pilot study |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9901123/ https://www.ncbi.nlm.nih.gov/pubmed/36747143 http://dx.doi.org/10.1186/s12880-023-00982-y |
work_keys_str_mv | AT yuanhaixia differentialdiagnosisofgallbladderneoplasticpolypsandcholesterolpolypswithradiomicsofdualmodalultrasoundapilotstudy AT wangchangyan differentialdiagnosisofgallbladderneoplasticpolypsandcholesterolpolypswithradiomicsofdualmodalultrasoundapilotstudy AT tangcongyu differentialdiagnosisofgallbladderneoplasticpolypsandcholesterolpolypswithradiomicsofdualmodalultrasoundapilotstudy AT youqiqin differentialdiagnosisofgallbladderneoplasticpolypsandcholesterolpolypswithradiomicsofdualmodalultrasoundapilotstudy AT zhangqi differentialdiagnosisofgallbladderneoplasticpolypsandcholesterolpolypswithradiomicsofdualmodalultrasoundapilotstudy AT wangwenping differentialdiagnosisofgallbladderneoplasticpolypsandcholesterolpolypswithradiomicsofdualmodalultrasoundapilotstudy |