Cargando…

A Novel Wide-band Dielectric Imaging System for Electro-anatomic Mapping and Monitoring in Radiofrequency Ablation and Cryoablation

BACKGROUND AND OBJECTIVES: A novel wide-band dielectric mapping system, named as KODEX-EPD (EPD Solutions, Philips, Best, the Netherlands), was effectively used in the EA mapping for atrial fibrillation (AF) ablation. To date, only a few studies have concentrated on the application of the KODEX-EPD...

Descripción completa

Detalles Bibliográficos
Autores principales: Li, Jian, Hua, Yu, Qiao, Lei, Wang, Bo, Pang, Xuefeng, Jia, He, Yu, Yang, Yu, Bo, Sun, Yingxian, Zhang, Xingang, Chen, Yanli
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Sciendo 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9901558/
https://www.ncbi.nlm.nih.gov/pubmed/36776237
http://dx.doi.org/10.2478/jtim-2022-0040
_version_ 1784883049791488000
author Li, Jian
Hua, Yu
Qiao, Lei
Wang, Bo
Pang, Xuefeng
Jia, He
Yu, Yang
Yu, Bo
Sun, Yingxian
Zhang, Xingang
Chen, Yanli
author_facet Li, Jian
Hua, Yu
Qiao, Lei
Wang, Bo
Pang, Xuefeng
Jia, He
Yu, Yang
Yu, Bo
Sun, Yingxian
Zhang, Xingang
Chen, Yanli
author_sort Li, Jian
collection PubMed
description BACKGROUND AND OBJECTIVES: A novel wide-band dielectric mapping system, named as KODEX-EPD (EPD Solutions, Philips, Best, the Netherlands), was effectively used in the EA mapping for atrial fibrillation (AF) ablation. To date, only a few studies have concentrated on the application of the KODEX-EPD system for ablating supraventricular tachycardia or ventricular premature beats (VPBs) in human models. This study aims to assess the applicability and efficiency of a novel three-dimensional electro-anatomic (EA) mapping system to improve the success rate of ablation. METHODS: This study included 11 consecutive patients who underwent ablation after EA mapping with the KODEX-EPD system. RESULTS: All surgeries were successfully performed using the KODEX-EPD system, including 6 cases who underwent ablation of paroxysmal supraventricular tachycardia (PSVT), 2 cases who received ablation of VPBs from right ventricular outflow tract (RVOT), and 3 cases who underwent cryoablation of AF. For ablation of PSVT or VPBs, the operation time was 31.4 (range, 24.0–38.0) min, in which a median operation time of 2.9 min was used to create anatomic images, and the median fluoroscopic dose was 7.4 mGy. For ablation of AF, the operation time was 56.0 (range, 49.0–62.0) min, in which a median of 4.3 (range, 3.4–5.2) min was used for constructing left atrium map, and the median fluoroscopic dose was 15.0 mGy. The operation time and the fluoroscopic dose were greatly shortened for all surgeries. CONCLUSION: The KODEX-EPD system is an effective and safe tool to guide the EA mapping, leading to improvement in the success rate of ablation. It can promote the ablation process with the reduced fluoroscopic dose, and it is also a promising tool for complex surgeries.
format Online
Article
Text
id pubmed-9901558
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Sciendo
record_format MEDLINE/PubMed
spelling pubmed-99015582023-02-09 A Novel Wide-band Dielectric Imaging System for Electro-anatomic Mapping and Monitoring in Radiofrequency Ablation and Cryoablation Li, Jian Hua, Yu Qiao, Lei Wang, Bo Pang, Xuefeng Jia, He Yu, Yang Yu, Bo Sun, Yingxian Zhang, Xingang Chen, Yanli J Transl Int Med Original Article BACKGROUND AND OBJECTIVES: A novel wide-band dielectric mapping system, named as KODEX-EPD (EPD Solutions, Philips, Best, the Netherlands), was effectively used in the EA mapping for atrial fibrillation (AF) ablation. To date, only a few studies have concentrated on the application of the KODEX-EPD system for ablating supraventricular tachycardia or ventricular premature beats (VPBs) in human models. This study aims to assess the applicability and efficiency of a novel three-dimensional electro-anatomic (EA) mapping system to improve the success rate of ablation. METHODS: This study included 11 consecutive patients who underwent ablation after EA mapping with the KODEX-EPD system. RESULTS: All surgeries were successfully performed using the KODEX-EPD system, including 6 cases who underwent ablation of paroxysmal supraventricular tachycardia (PSVT), 2 cases who received ablation of VPBs from right ventricular outflow tract (RVOT), and 3 cases who underwent cryoablation of AF. For ablation of PSVT or VPBs, the operation time was 31.4 (range, 24.0–38.0) min, in which a median operation time of 2.9 min was used to create anatomic images, and the median fluoroscopic dose was 7.4 mGy. For ablation of AF, the operation time was 56.0 (range, 49.0–62.0) min, in which a median of 4.3 (range, 3.4–5.2) min was used for constructing left atrium map, and the median fluoroscopic dose was 15.0 mGy. The operation time and the fluoroscopic dose were greatly shortened for all surgeries. CONCLUSION: The KODEX-EPD system is an effective and safe tool to guide the EA mapping, leading to improvement in the success rate of ablation. It can promote the ablation process with the reduced fluoroscopic dose, and it is also a promising tool for complex surgeries. Sciendo 2022-08-31 /pmc/articles/PMC9901558/ /pubmed/36776237 http://dx.doi.org/10.2478/jtim-2022-0040 Text en © 2022 Jian Li, Yu Hua, Lei Qiao, Bo Wang, Xuefeng Pang, He Jia, Yang Yu, Bo Yu, Yingxian Sun, Xingang Zhang, Yanli Chen, published by Sciendo https://creativecommons.org/licenses/by-nc-nd/3.0/This work is licensed under the Creative Commons Attribution-NonCommercial-NoDerivatives 3.0 License.
spellingShingle Original Article
Li, Jian
Hua, Yu
Qiao, Lei
Wang, Bo
Pang, Xuefeng
Jia, He
Yu, Yang
Yu, Bo
Sun, Yingxian
Zhang, Xingang
Chen, Yanli
A Novel Wide-band Dielectric Imaging System for Electro-anatomic Mapping and Monitoring in Radiofrequency Ablation and Cryoablation
title A Novel Wide-band Dielectric Imaging System for Electro-anatomic Mapping and Monitoring in Radiofrequency Ablation and Cryoablation
title_full A Novel Wide-band Dielectric Imaging System for Electro-anatomic Mapping and Monitoring in Radiofrequency Ablation and Cryoablation
title_fullStr A Novel Wide-band Dielectric Imaging System for Electro-anatomic Mapping and Monitoring in Radiofrequency Ablation and Cryoablation
title_full_unstemmed A Novel Wide-band Dielectric Imaging System for Electro-anatomic Mapping and Monitoring in Radiofrequency Ablation and Cryoablation
title_short A Novel Wide-band Dielectric Imaging System for Electro-anatomic Mapping and Monitoring in Radiofrequency Ablation and Cryoablation
title_sort novel wide-band dielectric imaging system for electro-anatomic mapping and monitoring in radiofrequency ablation and cryoablation
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9901558/
https://www.ncbi.nlm.nih.gov/pubmed/36776237
http://dx.doi.org/10.2478/jtim-2022-0040
work_keys_str_mv AT lijian anovelwidebanddielectricimagingsystemforelectroanatomicmappingandmonitoringinradiofrequencyablationandcryoablation
AT huayu anovelwidebanddielectricimagingsystemforelectroanatomicmappingandmonitoringinradiofrequencyablationandcryoablation
AT qiaolei anovelwidebanddielectricimagingsystemforelectroanatomicmappingandmonitoringinradiofrequencyablationandcryoablation
AT wangbo anovelwidebanddielectricimagingsystemforelectroanatomicmappingandmonitoringinradiofrequencyablationandcryoablation
AT pangxuefeng anovelwidebanddielectricimagingsystemforelectroanatomicmappingandmonitoringinradiofrequencyablationandcryoablation
AT jiahe anovelwidebanddielectricimagingsystemforelectroanatomicmappingandmonitoringinradiofrequencyablationandcryoablation
AT yuyang anovelwidebanddielectricimagingsystemforelectroanatomicmappingandmonitoringinradiofrequencyablationandcryoablation
AT yubo anovelwidebanddielectricimagingsystemforelectroanatomicmappingandmonitoringinradiofrequencyablationandcryoablation
AT sunyingxian anovelwidebanddielectricimagingsystemforelectroanatomicmappingandmonitoringinradiofrequencyablationandcryoablation
AT zhangxingang anovelwidebanddielectricimagingsystemforelectroanatomicmappingandmonitoringinradiofrequencyablationandcryoablation
AT chenyanli anovelwidebanddielectricimagingsystemforelectroanatomicmappingandmonitoringinradiofrequencyablationandcryoablation
AT lijian novelwidebanddielectricimagingsystemforelectroanatomicmappingandmonitoringinradiofrequencyablationandcryoablation
AT huayu novelwidebanddielectricimagingsystemforelectroanatomicmappingandmonitoringinradiofrequencyablationandcryoablation
AT qiaolei novelwidebanddielectricimagingsystemforelectroanatomicmappingandmonitoringinradiofrequencyablationandcryoablation
AT wangbo novelwidebanddielectricimagingsystemforelectroanatomicmappingandmonitoringinradiofrequencyablationandcryoablation
AT pangxuefeng novelwidebanddielectricimagingsystemforelectroanatomicmappingandmonitoringinradiofrequencyablationandcryoablation
AT jiahe novelwidebanddielectricimagingsystemforelectroanatomicmappingandmonitoringinradiofrequencyablationandcryoablation
AT yuyang novelwidebanddielectricimagingsystemforelectroanatomicmappingandmonitoringinradiofrequencyablationandcryoablation
AT yubo novelwidebanddielectricimagingsystemforelectroanatomicmappingandmonitoringinradiofrequencyablationandcryoablation
AT sunyingxian novelwidebanddielectricimagingsystemforelectroanatomicmappingandmonitoringinradiofrequencyablationandcryoablation
AT zhangxingang novelwidebanddielectricimagingsystemforelectroanatomicmappingandmonitoringinradiofrequencyablationandcryoablation
AT chenyanli novelwidebanddielectricimagingsystemforelectroanatomicmappingandmonitoringinradiofrequencyablationandcryoablation