Cargando…

Precision of Myocardial Blood Flow and Flow Reserve Measurement During CZT SPECT Perfusion Imaging Processing: Intra- and Interobserver Variability

The aim of this study was to evaluate the reproducibility of myocardial blood flow (MBF) and myocardial flow reserve (MFR) measurement in patients referred for dynamic SPECT. Methods: We retrospectively analyzed patients referred for myocardial perfusion imaging. SPECT data were acquired on a cadmiu...

Descripción completa

Detalles Bibliográficos
Autores principales: Bailly, Matthieu, Thibault, Frédérique, Metrard, Gilles, Courtehoux, Maxime, Angoulvant, Denis, Ribeiro, Maria Joao
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Society of Nuclear Medicine 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9902854/
https://www.ncbi.nlm.nih.gov/pubmed/36109180
http://dx.doi.org/10.2967/jnumed.122.264454
_version_ 1784883351117627392
author Bailly, Matthieu
Thibault, Frédérique
Metrard, Gilles
Courtehoux, Maxime
Angoulvant, Denis
Ribeiro, Maria Joao
author_facet Bailly, Matthieu
Thibault, Frédérique
Metrard, Gilles
Courtehoux, Maxime
Angoulvant, Denis
Ribeiro, Maria Joao
author_sort Bailly, Matthieu
collection PubMed
description The aim of this study was to evaluate the reproducibility of myocardial blood flow (MBF) and myocardial flow reserve (MFR) measurement in patients referred for dynamic SPECT. Methods: We retrospectively analyzed patients referred for myocardial perfusion imaging. SPECT data were acquired on a cadmium zinc telluride–based pinhole cardiac camera in list mode using a stress (251 ± 15 MBq)/rest (512 ± 26 MBq) 1-d (99m)Tc-tetrofosmin protocol. Kinetic analyses were done with software using a 1-tissue-compartment model and converted to MBF using a previously determined extraction fraction correction. MFR was analyzed and compared globally and regionally. Motion detection was applied, but not attenuation correction. Results: In total, 124 patients (64 male, 60 female) were included, and SPECT acquisitions were twice reconstructed by the same nuclear medicine board-certified physician for 50 patients and by 2 different physicians for 74. Both intra- and interobserver measurements of global MFR had no significant bias (−0.01 [P = 0.94] and 0.01 [P = 0.67], respectively). However, rest MBF and stress MBF were significantly different in global left ventricular evaluation (P = 0.001 and P = 0.002, respectively) and in the anterior territory (P < 0.0001) on interuser analysis. The average coefficient of variation was 15%–30% of the mean stress MBF if the analysis was performed by the same physician or 2 different physicians and was around 20% of the mean MFR independently of the processing physician. Using the MFR threshold of 2, we noticed good intrauser agreement, whereas it was moderate when the users were different (κ = 0.75 [95% CI, 0.56–0.94] vs. 0.56 [95% CI, 0.36–0.75], respectively). Conclusion: Repeated measurements of global MFR by the same physician or 2 different physicians were similar, with an average coefficient of variation of 20%. Better reproducibility was achieved for intrauser MBF evaluation. Automation of processing is needed to improve reproducibility.
format Online
Article
Text
id pubmed-9902854
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Society of Nuclear Medicine
record_format MEDLINE/PubMed
spelling pubmed-99028542023-04-19 Precision of Myocardial Blood Flow and Flow Reserve Measurement During CZT SPECT Perfusion Imaging Processing: Intra- and Interobserver Variability Bailly, Matthieu Thibault, Frédérique Metrard, Gilles Courtehoux, Maxime Angoulvant, Denis Ribeiro, Maria Joao J Nucl Med Clinical Investigation The aim of this study was to evaluate the reproducibility of myocardial blood flow (MBF) and myocardial flow reserve (MFR) measurement in patients referred for dynamic SPECT. Methods: We retrospectively analyzed patients referred for myocardial perfusion imaging. SPECT data were acquired on a cadmium zinc telluride–based pinhole cardiac camera in list mode using a stress (251 ± 15 MBq)/rest (512 ± 26 MBq) 1-d (99m)Tc-tetrofosmin protocol. Kinetic analyses were done with software using a 1-tissue-compartment model and converted to MBF using a previously determined extraction fraction correction. MFR was analyzed and compared globally and regionally. Motion detection was applied, but not attenuation correction. Results: In total, 124 patients (64 male, 60 female) were included, and SPECT acquisitions were twice reconstructed by the same nuclear medicine board-certified physician for 50 patients and by 2 different physicians for 74. Both intra- and interobserver measurements of global MFR had no significant bias (−0.01 [P = 0.94] and 0.01 [P = 0.67], respectively). However, rest MBF and stress MBF were significantly different in global left ventricular evaluation (P = 0.001 and P = 0.002, respectively) and in the anterior territory (P < 0.0001) on interuser analysis. The average coefficient of variation was 15%–30% of the mean stress MBF if the analysis was performed by the same physician or 2 different physicians and was around 20% of the mean MFR independently of the processing physician. Using the MFR threshold of 2, we noticed good intrauser agreement, whereas it was moderate when the users were different (κ = 0.75 [95% CI, 0.56–0.94] vs. 0.56 [95% CI, 0.36–0.75], respectively). Conclusion: Repeated measurements of global MFR by the same physician or 2 different physicians were similar, with an average coefficient of variation of 20%. Better reproducibility was achieved for intrauser MBF evaluation. Automation of processing is needed to improve reproducibility. Society of Nuclear Medicine 2023-02 /pmc/articles/PMC9902854/ /pubmed/36109180 http://dx.doi.org/10.2967/jnumed.122.264454 Text en © 2023 by the Society of Nuclear Medicine and Molecular Imaging. https://creativecommons.org/licenses/by/4.0/Immediate Open Access: Creative Commons Attribution 4.0 International License (CC BY) allows users to share and adapt with attribution, excluding materials credited to previous publications. License: https://creativecommons.org/licenses/by/4.0/. Details: http://jnm.snmjournals.org/site/misc/permission.xhtml.
spellingShingle Clinical Investigation
Bailly, Matthieu
Thibault, Frédérique
Metrard, Gilles
Courtehoux, Maxime
Angoulvant, Denis
Ribeiro, Maria Joao
Precision of Myocardial Blood Flow and Flow Reserve Measurement During CZT SPECT Perfusion Imaging Processing: Intra- and Interobserver Variability
title Precision of Myocardial Blood Flow and Flow Reserve Measurement During CZT SPECT Perfusion Imaging Processing: Intra- and Interobserver Variability
title_full Precision of Myocardial Blood Flow and Flow Reserve Measurement During CZT SPECT Perfusion Imaging Processing: Intra- and Interobserver Variability
title_fullStr Precision of Myocardial Blood Flow and Flow Reserve Measurement During CZT SPECT Perfusion Imaging Processing: Intra- and Interobserver Variability
title_full_unstemmed Precision of Myocardial Blood Flow and Flow Reserve Measurement During CZT SPECT Perfusion Imaging Processing: Intra- and Interobserver Variability
title_short Precision of Myocardial Blood Flow and Flow Reserve Measurement During CZT SPECT Perfusion Imaging Processing: Intra- and Interobserver Variability
title_sort precision of myocardial blood flow and flow reserve measurement during czt spect perfusion imaging processing: intra- and interobserver variability
topic Clinical Investigation
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9902854/
https://www.ncbi.nlm.nih.gov/pubmed/36109180
http://dx.doi.org/10.2967/jnumed.122.264454
work_keys_str_mv AT baillymatthieu precisionofmyocardialbloodflowandflowreservemeasurementduringcztspectperfusionimagingprocessingintraandinterobservervariability
AT thibaultfrederique precisionofmyocardialbloodflowandflowreservemeasurementduringcztspectperfusionimagingprocessingintraandinterobservervariability
AT metrardgilles precisionofmyocardialbloodflowandflowreservemeasurementduringcztspectperfusionimagingprocessingintraandinterobservervariability
AT courtehouxmaxime precisionofmyocardialbloodflowandflowreservemeasurementduringcztspectperfusionimagingprocessingintraandinterobservervariability
AT angoulvantdenis precisionofmyocardialbloodflowandflowreservemeasurementduringcztspectperfusionimagingprocessingintraandinterobservervariability
AT ribeiromariajoao precisionofmyocardialbloodflowandflowreservemeasurementduringcztspectperfusionimagingprocessingintraandinterobservervariability