A radiographic study of dorsovolar wrist axes and a database of angular measurements on axial computed tomography images

OBJECTIVES: This study aims to identify the most accurate dorsovolar principal axis of the distal radius and carpus identified on axial computed tomography (CT) sections and to establish normative data for angular measurements among these axes. PATIENTS AND METHODS: Between December 2019 and Decembe...

Descripción completa

Detalles Bibliográficos
Autores principales: Arık, Atilla, Hatipoğlu, Mustafa Yasin, Özcanyüz, Burç, Bulut, Mustafa, Seyfettinoğlu, Fırat
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Bayçınar Medical Publishing 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9903112/
https://www.ncbi.nlm.nih.gov/pubmed/36700280
http://dx.doi.org/10.52312/jdrs.2023.872
_version_ 1784883409290526720
author Arık, Atilla
Hatipoğlu, Mustafa Yasin
Özcanyüz, Burç
Bulut, Mustafa
Seyfettinoğlu, Fırat
author_facet Arık, Atilla
Hatipoğlu, Mustafa Yasin
Özcanyüz, Burç
Bulut, Mustafa
Seyfettinoğlu, Fırat
author_sort Arık, Atilla
collection PubMed
description OBJECTIVES: This study aims to identify the most accurate dorsovolar principal axis of the distal radius and carpus identified on axial computed tomography (CT) sections and to establish normative data for angular measurements among these axes. PATIENTS AND METHODS: Between December 2019 and December 2021, normal axial CT images of wrists of a total of 42 individuals (25 males, 17 females; mean age: 31±8.4 years; range, 18 to 45 years) were retrospectively analyzed. Eight axes were identified on axial CT images: four distal radial axes (the volar cortical, medial cortical, central, and sigmoid notch axes) and four carpal axes (the scapholunate, lunotriquetral, capitohamate, and pisotrapezial axes). Twenty-two angular parameters were measured with reference to four principal axes (the volar cortical, medial cortical, central, and pisotrapezial axes). RESULTS: The mean sigmoid notch rotation (version) angles relative to the four principal axes were 8±5° (range, –2° to 18°), 6±5° (range, –2° to 13°), 1±5° (range, –8° to 14°), and 4±4° (range, –3° to 15°), respectively. The mean scapholunate rotation angles were –13±5° (range, –27° to –6°), –15±6° (range, –29° to –8°), –21±5° (range, –30° to –11°), and –8±5° (range, –28° to –6°), respectively. Among four principal axes, the volar cortical and medial cortical axes were nearly collinear with both of relatively fixed carpal axes. The four principal axes showed angular differences between 2° and 8° with each other. There was no significant difference between men and women for all measurements. CONCLUSION: The axial CT sections can be used to describe the various angulations between the normal wrist axes such as the sigmoid notch and scapholunate joint rotation angles. Despite slight differences among the four principal axes, the volar cortical and medial cortical axes are more consistent with the relatively fixed carpal axes.
format Online
Article
Text
id pubmed-9903112
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Bayçınar Medical Publishing
record_format MEDLINE/PubMed
spelling pubmed-99031122023-02-14 A radiographic study of dorsovolar wrist axes and a database of angular measurements on axial computed tomography images Arık, Atilla Hatipoğlu, Mustafa Yasin Özcanyüz, Burç Bulut, Mustafa Seyfettinoğlu, Fırat Jt Dis Relat Surg Original Article OBJECTIVES: This study aims to identify the most accurate dorsovolar principal axis of the distal radius and carpus identified on axial computed tomography (CT) sections and to establish normative data for angular measurements among these axes. PATIENTS AND METHODS: Between December 2019 and December 2021, normal axial CT images of wrists of a total of 42 individuals (25 males, 17 females; mean age: 31±8.4 years; range, 18 to 45 years) were retrospectively analyzed. Eight axes were identified on axial CT images: four distal radial axes (the volar cortical, medial cortical, central, and sigmoid notch axes) and four carpal axes (the scapholunate, lunotriquetral, capitohamate, and pisotrapezial axes). Twenty-two angular parameters were measured with reference to four principal axes (the volar cortical, medial cortical, central, and pisotrapezial axes). RESULTS: The mean sigmoid notch rotation (version) angles relative to the four principal axes were 8±5° (range, –2° to 18°), 6±5° (range, –2° to 13°), 1±5° (range, –8° to 14°), and 4±4° (range, –3° to 15°), respectively. The mean scapholunate rotation angles were –13±5° (range, –27° to –6°), –15±6° (range, –29° to –8°), –21±5° (range, –30° to –11°), and –8±5° (range, –28° to –6°), respectively. Among four principal axes, the volar cortical and medial cortical axes were nearly collinear with both of relatively fixed carpal axes. The four principal axes showed angular differences between 2° and 8° with each other. There was no significant difference between men and women for all measurements. CONCLUSION: The axial CT sections can be used to describe the various angulations between the normal wrist axes such as the sigmoid notch and scapholunate joint rotation angles. Despite slight differences among the four principal axes, the volar cortical and medial cortical axes are more consistent with the relatively fixed carpal axes. Bayçınar Medical Publishing 2022-12-27 /pmc/articles/PMC9903112/ /pubmed/36700280 http://dx.doi.org/10.52312/jdrs.2023.872 Text en Copyright © 2023, Turkish Joint Diseases Foundation https://creativecommons.org/licenses/by-nc/4.0/This is an open access article under the terms of the Creative Commons Attribution-NonCommercial License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited and is not used for commercial purposes.
spellingShingle Original Article
Arık, Atilla
Hatipoğlu, Mustafa Yasin
Özcanyüz, Burç
Bulut, Mustafa
Seyfettinoğlu, Fırat
A radiographic study of dorsovolar wrist axes and a database of angular measurements on axial computed tomography images
title A radiographic study of dorsovolar wrist axes and a database of angular measurements on axial computed tomography images
title_full A radiographic study of dorsovolar wrist axes and a database of angular measurements on axial computed tomography images
title_fullStr A radiographic study of dorsovolar wrist axes and a database of angular measurements on axial computed tomography images
title_full_unstemmed A radiographic study of dorsovolar wrist axes and a database of angular measurements on axial computed tomography images
title_short A radiographic study of dorsovolar wrist axes and a database of angular measurements on axial computed tomography images
title_sort radiographic study of dorsovolar wrist axes and a database of angular measurements on axial computed tomography images
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9903112/
https://www.ncbi.nlm.nih.gov/pubmed/36700280
http://dx.doi.org/10.52312/jdrs.2023.872
work_keys_str_mv AT arıkatilla aradiographicstudyofdorsovolarwristaxesandadatabaseofangularmeasurementsonaxialcomputedtomographyimages
AT hatipoglumustafayasin aradiographicstudyofdorsovolarwristaxesandadatabaseofangularmeasurementsonaxialcomputedtomographyimages
AT ozcanyuzburc aradiographicstudyofdorsovolarwristaxesandadatabaseofangularmeasurementsonaxialcomputedtomographyimages
AT bulutmustafa aradiographicstudyofdorsovolarwristaxesandadatabaseofangularmeasurementsonaxialcomputedtomographyimages
AT seyfettinoglufırat aradiographicstudyofdorsovolarwristaxesandadatabaseofangularmeasurementsonaxialcomputedtomographyimages
AT arıkatilla radiographicstudyofdorsovolarwristaxesandadatabaseofangularmeasurementsonaxialcomputedtomographyimages
AT hatipoglumustafayasin radiographicstudyofdorsovolarwristaxesandadatabaseofangularmeasurementsonaxialcomputedtomographyimages
AT ozcanyuzburc radiographicstudyofdorsovolarwristaxesandadatabaseofangularmeasurementsonaxialcomputedtomographyimages
AT bulutmustafa radiographicstudyofdorsovolarwristaxesandadatabaseofangularmeasurementsonaxialcomputedtomographyimages
AT seyfettinoglufırat radiographicstudyofdorsovolarwristaxesandadatabaseofangularmeasurementsonaxialcomputedtomographyimages