Cargando…

Polyetherketoneketone Mesh for Alveolar Bone Augmentation: Geometric Parameter Design and Finite Element Analysis

OBJECTIVE: To evaluate the mechanical properties of porous polyetherketoneketone (PEKK) meshes with different thicknesses, pore sizes, and porosities through finite element analysis to provide an optimal PEKK design for alveolar bone augmentation in the posterior mandibular region. METHODS: A three-...

Descripción completa

Detalles Bibliográficos
Autores principales: Hao, Xiaowen, Wang, Wei, Wang, Chenxi, Han, Jianmin, Zhang, Yu
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9904908/
https://www.ncbi.nlm.nih.gov/pubmed/36760836
http://dx.doi.org/10.1155/2023/8487380
_version_ 1784883721814409216
author Hao, Xiaowen
Wang, Wei
Wang, Chenxi
Han, Jianmin
Zhang, Yu
author_facet Hao, Xiaowen
Wang, Wei
Wang, Chenxi
Han, Jianmin
Zhang, Yu
author_sort Hao, Xiaowen
collection PubMed
description OBJECTIVE: To evaluate the mechanical properties of porous polyetherketoneketone (PEKK) meshes with different thicknesses, pore sizes, and porosities through finite element analysis to provide an optimal PEKK design for alveolar bone augmentation in the posterior mandibular region. METHODS: A three-dimensional evaluation model of severe alveolar bone defects in the mandibular posterior was constructed based on cone beam computerized tomography (CBCT) data. Then, PEKK meshes with different structural designs were obtained. Two key parameters were set with different values: five levels of thickness (0.2 mm, 0.3 mm, 0.4 mm, 0.5 mm, and 0.6 mm) and three levels of pore size (1 mm, 2 mm, and 3 mm) with a corresponding porosity of 19.18%–42.67%. A 100 N physiological force was simultaneously loaded by finite element analysis (FEA), and the deformation and stress data were outputted for further analysis. RESULTS: The deformation and stress of the PEKK meshes are negatively correlated with the changes in thickness and positively correlated with the changes in pore size. The FEA results show that the maximum deformation, equivalent stress, and maximum principal stress of the PEKK meshes are 0.168 mm–0.478 mm, 49.243 MPa–124.890 MPa, and 31.549 MPa–104.200 MPa, respectively. The PEKK mesh group with a thickness of 0.2 mm, pore size of 3 mm, and porosity of 42.67% is in danger of plastic deformation or even fracture during use. CONCLUSION: According to the FEA results, the PEKK meshes with larger thicknesses and smaller pore sizes and porosities behave better. In consideration of reducing soft tissue stimulation and promoting bone regeneration, an ultrathin porous PEKK mesh with a pore size of no more than 3 mm, porosity of no more than 42.67%, and thickness of 0.2 mm can be used clinically to meet the mechanical performance requirements of the guided bone regeneration (GBR) structure.
format Online
Article
Text
id pubmed-9904908
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Hindawi
record_format MEDLINE/PubMed
spelling pubmed-99049082023-02-08 Polyetherketoneketone Mesh for Alveolar Bone Augmentation: Geometric Parameter Design and Finite Element Analysis Hao, Xiaowen Wang, Wei Wang, Chenxi Han, Jianmin Zhang, Yu J Healthc Eng Research Article OBJECTIVE: To evaluate the mechanical properties of porous polyetherketoneketone (PEKK) meshes with different thicknesses, pore sizes, and porosities through finite element analysis to provide an optimal PEKK design for alveolar bone augmentation in the posterior mandibular region. METHODS: A three-dimensional evaluation model of severe alveolar bone defects in the mandibular posterior was constructed based on cone beam computerized tomography (CBCT) data. Then, PEKK meshes with different structural designs were obtained. Two key parameters were set with different values: five levels of thickness (0.2 mm, 0.3 mm, 0.4 mm, 0.5 mm, and 0.6 mm) and three levels of pore size (1 mm, 2 mm, and 3 mm) with a corresponding porosity of 19.18%–42.67%. A 100 N physiological force was simultaneously loaded by finite element analysis (FEA), and the deformation and stress data were outputted for further analysis. RESULTS: The deformation and stress of the PEKK meshes are negatively correlated with the changes in thickness and positively correlated with the changes in pore size. The FEA results show that the maximum deformation, equivalent stress, and maximum principal stress of the PEKK meshes are 0.168 mm–0.478 mm, 49.243 MPa–124.890 MPa, and 31.549 MPa–104.200 MPa, respectively. The PEKK mesh group with a thickness of 0.2 mm, pore size of 3 mm, and porosity of 42.67% is in danger of plastic deformation or even fracture during use. CONCLUSION: According to the FEA results, the PEKK meshes with larger thicknesses and smaller pore sizes and porosities behave better. In consideration of reducing soft tissue stimulation and promoting bone regeneration, an ultrathin porous PEKK mesh with a pore size of no more than 3 mm, porosity of no more than 42.67%, and thickness of 0.2 mm can be used clinically to meet the mechanical performance requirements of the guided bone regeneration (GBR) structure. Hindawi 2023-01-31 /pmc/articles/PMC9904908/ /pubmed/36760836 http://dx.doi.org/10.1155/2023/8487380 Text en Copyright © 2023 Xiaowen Hao et al. https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Hao, Xiaowen
Wang, Wei
Wang, Chenxi
Han, Jianmin
Zhang, Yu
Polyetherketoneketone Mesh for Alveolar Bone Augmentation: Geometric Parameter Design and Finite Element Analysis
title Polyetherketoneketone Mesh for Alveolar Bone Augmentation: Geometric Parameter Design and Finite Element Analysis
title_full Polyetherketoneketone Mesh for Alveolar Bone Augmentation: Geometric Parameter Design and Finite Element Analysis
title_fullStr Polyetherketoneketone Mesh for Alveolar Bone Augmentation: Geometric Parameter Design and Finite Element Analysis
title_full_unstemmed Polyetherketoneketone Mesh for Alveolar Bone Augmentation: Geometric Parameter Design and Finite Element Analysis
title_short Polyetherketoneketone Mesh for Alveolar Bone Augmentation: Geometric Parameter Design and Finite Element Analysis
title_sort polyetherketoneketone mesh for alveolar bone augmentation: geometric parameter design and finite element analysis
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9904908/
https://www.ncbi.nlm.nih.gov/pubmed/36760836
http://dx.doi.org/10.1155/2023/8487380
work_keys_str_mv AT haoxiaowen polyetherketoneketonemeshforalveolarboneaugmentationgeometricparameterdesignandfiniteelementanalysis
AT wangwei polyetherketoneketonemeshforalveolarboneaugmentationgeometricparameterdesignandfiniteelementanalysis
AT wangchenxi polyetherketoneketonemeshforalveolarboneaugmentationgeometricparameterdesignandfiniteelementanalysis
AT hanjianmin polyetherketoneketonemeshforalveolarboneaugmentationgeometricparameterdesignandfiniteelementanalysis
AT zhangyu polyetherketoneketonemeshforalveolarboneaugmentationgeometricparameterdesignandfiniteelementanalysis