Cargando…

Diagnostic accuracy of contrast-enhanced ultrasound synchronized with shear wave elastography in the differential diagnosis of benign and malignant breast lesions: a diagnostic test

BACKGROUND: Breast cancer (BC) is one of the most common malignancies affecting women. Timely and accurate diagnosis is crucial for treatment and prognosis. Some studies have found that elastography combined with microperfusion characteristics, which are mostly described by contrast-enhanced ultraso...

Descripción completa

Detalles Bibliográficos
Autores principales: He, Huiling, Wu, Xiaojin, Jiang, Meijuan, Xu, Zhikang, Zhang, Xuanxuan, Pan, Jianlian, Fu, Xinyu, Luo, Yunkai, Chen, Jian
Formato: Online Artículo Texto
Lenguaje:English
Publicado: AME Publishing Company 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9906099/
https://www.ncbi.nlm.nih.gov/pubmed/36761482
http://dx.doi.org/10.21037/gs-22-684
_version_ 1784883937747664896
author He, Huiling
Wu, Xiaojin
Jiang, Meijuan
Xu, Zhikang
Zhang, Xuanxuan
Pan, Jianlian
Fu, Xinyu
Luo, Yunkai
Chen, Jian
author_facet He, Huiling
Wu, Xiaojin
Jiang, Meijuan
Xu, Zhikang
Zhang, Xuanxuan
Pan, Jianlian
Fu, Xinyu
Luo, Yunkai
Chen, Jian
author_sort He, Huiling
collection PubMed
description BACKGROUND: Breast cancer (BC) is one of the most common malignancies affecting women. Timely and accurate diagnosis is crucial for treatment and prognosis. Some studies have found that elastography combined with microperfusion characteristics, which are mostly described by contrast-enhanced ultrasound (CEUS), could help in the diagnosis of breast lesions. This study aimed to assess the diagnostic performance of CEUS synchronized with shear wave elastography (SWE) in discriminating between benign and malignant breast lesions by using real-time contrast elastography images to analyze shell elasticity and contrast intensity. METHODS: A total of 26 pathologically confirmed breast lesions in 26 patients were retrospectively reviewed. Each patient underwent conventional B-mode ultrasound, CEUS, and then SWE data was obtained from a frame of image that was almost identical to the B-mode and CEUS images when acquiring time to peak (TTP). Breast lesions were evaluated based on the Breast Imaging Reporting and Data System (BI-RADS) and quantitative characteristics that describe the stiffness and intensity of contrast of the 1.0–3.0 mm shell region. Quantitative aspects of the inner lesions and shell on the elastogram included the maximum (Emax), mean (Emean), and minimum (Emin) Young’s moduli. Quantitative enhanced features included maximum (Imax) and mean (Imean) intensity. We took postoperative pathological results as the gold standard. Receiver operating characteristic (ROC) curves were used to compare the diagnostic efficacy of the 2 examination modalities, either alone or in combination. RESULTS: The age of the patients ranged from 23 to 76 years, with a 42.5-year average age. In all breast lesions, 19 were benign and 7 were malignant. SWE synchronized with CEUS can effectively improve the diagnostic performance of breast lesions, and Emean + Imean and Emax + Emean + Imean of shell at 1.0 mm both had the highest area under the curve (AUC) of 0.86 [95% confidence interval (CI): 0.67, 0.96], with the sensitivity and specificity of 71.43% and 89.47%, respectively. CONCLUSIONS: The combination of CEUS and SWE has a better diagnostic value in differentiating benign and malignant breast lesions compared to separate techniques.
format Online
Article
Text
id pubmed-9906099
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher AME Publishing Company
record_format MEDLINE/PubMed
spelling pubmed-99060992023-02-08 Diagnostic accuracy of contrast-enhanced ultrasound synchronized with shear wave elastography in the differential diagnosis of benign and malignant breast lesions: a diagnostic test He, Huiling Wu, Xiaojin Jiang, Meijuan Xu, Zhikang Zhang, Xuanxuan Pan, Jianlian Fu, Xinyu Luo, Yunkai Chen, Jian Gland Surg Original Article BACKGROUND: Breast cancer (BC) is one of the most common malignancies affecting women. Timely and accurate diagnosis is crucial for treatment and prognosis. Some studies have found that elastography combined with microperfusion characteristics, which are mostly described by contrast-enhanced ultrasound (CEUS), could help in the diagnosis of breast lesions. This study aimed to assess the diagnostic performance of CEUS synchronized with shear wave elastography (SWE) in discriminating between benign and malignant breast lesions by using real-time contrast elastography images to analyze shell elasticity and contrast intensity. METHODS: A total of 26 pathologically confirmed breast lesions in 26 patients were retrospectively reviewed. Each patient underwent conventional B-mode ultrasound, CEUS, and then SWE data was obtained from a frame of image that was almost identical to the B-mode and CEUS images when acquiring time to peak (TTP). Breast lesions were evaluated based on the Breast Imaging Reporting and Data System (BI-RADS) and quantitative characteristics that describe the stiffness and intensity of contrast of the 1.0–3.0 mm shell region. Quantitative aspects of the inner lesions and shell on the elastogram included the maximum (Emax), mean (Emean), and minimum (Emin) Young’s moduli. Quantitative enhanced features included maximum (Imax) and mean (Imean) intensity. We took postoperative pathological results as the gold standard. Receiver operating characteristic (ROC) curves were used to compare the diagnostic efficacy of the 2 examination modalities, either alone or in combination. RESULTS: The age of the patients ranged from 23 to 76 years, with a 42.5-year average age. In all breast lesions, 19 were benign and 7 were malignant. SWE synchronized with CEUS can effectively improve the diagnostic performance of breast lesions, and Emean + Imean and Emax + Emean + Imean of shell at 1.0 mm both had the highest area under the curve (AUC) of 0.86 [95% confidence interval (CI): 0.67, 0.96], with the sensitivity and specificity of 71.43% and 89.47%, respectively. CONCLUSIONS: The combination of CEUS and SWE has a better diagnostic value in differentiating benign and malignant breast lesions compared to separate techniques. AME Publishing Company 2023-01-13 2023-01-01 /pmc/articles/PMC9906099/ /pubmed/36761482 http://dx.doi.org/10.21037/gs-22-684 Text en 2023 Gland Surgery. All rights reserved. https://creativecommons.org/licenses/by-nc-nd/4.0/Open Access Statement: This is an Open Access article distributed in accordance with the Creative Commons Attribution-NonCommercial-NoDerivs 4.0 International License (CC BY-NC-ND 4.0), which permits the non-commercial replication and distribution of the article with the strict proviso that no changes or edits are made and the original work is properly cited (including links to both the formal publication through the relevant DOI and the license). See: https://creativecommons.org/licenses/by-nc-nd/4.0 (https://creativecommons.org/licenses/by-nc-nd/4.0/) .
spellingShingle Original Article
He, Huiling
Wu, Xiaojin
Jiang, Meijuan
Xu, Zhikang
Zhang, Xuanxuan
Pan, Jianlian
Fu, Xinyu
Luo, Yunkai
Chen, Jian
Diagnostic accuracy of contrast-enhanced ultrasound synchronized with shear wave elastography in the differential diagnosis of benign and malignant breast lesions: a diagnostic test
title Diagnostic accuracy of contrast-enhanced ultrasound synchronized with shear wave elastography in the differential diagnosis of benign and malignant breast lesions: a diagnostic test
title_full Diagnostic accuracy of contrast-enhanced ultrasound synchronized with shear wave elastography in the differential diagnosis of benign and malignant breast lesions: a diagnostic test
title_fullStr Diagnostic accuracy of contrast-enhanced ultrasound synchronized with shear wave elastography in the differential diagnosis of benign and malignant breast lesions: a diagnostic test
title_full_unstemmed Diagnostic accuracy of contrast-enhanced ultrasound synchronized with shear wave elastography in the differential diagnosis of benign and malignant breast lesions: a diagnostic test
title_short Diagnostic accuracy of contrast-enhanced ultrasound synchronized with shear wave elastography in the differential diagnosis of benign and malignant breast lesions: a diagnostic test
title_sort diagnostic accuracy of contrast-enhanced ultrasound synchronized with shear wave elastography in the differential diagnosis of benign and malignant breast lesions: a diagnostic test
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9906099/
https://www.ncbi.nlm.nih.gov/pubmed/36761482
http://dx.doi.org/10.21037/gs-22-684
work_keys_str_mv AT hehuiling diagnosticaccuracyofcontrastenhancedultrasoundsynchronizedwithshearwaveelastographyinthedifferentialdiagnosisofbenignandmalignantbreastlesionsadiagnostictest
AT wuxiaojin diagnosticaccuracyofcontrastenhancedultrasoundsynchronizedwithshearwaveelastographyinthedifferentialdiagnosisofbenignandmalignantbreastlesionsadiagnostictest
AT jiangmeijuan diagnosticaccuracyofcontrastenhancedultrasoundsynchronizedwithshearwaveelastographyinthedifferentialdiagnosisofbenignandmalignantbreastlesionsadiagnostictest
AT xuzhikang diagnosticaccuracyofcontrastenhancedultrasoundsynchronizedwithshearwaveelastographyinthedifferentialdiagnosisofbenignandmalignantbreastlesionsadiagnostictest
AT zhangxuanxuan diagnosticaccuracyofcontrastenhancedultrasoundsynchronizedwithshearwaveelastographyinthedifferentialdiagnosisofbenignandmalignantbreastlesionsadiagnostictest
AT panjianlian diagnosticaccuracyofcontrastenhancedultrasoundsynchronizedwithshearwaveelastographyinthedifferentialdiagnosisofbenignandmalignantbreastlesionsadiagnostictest
AT fuxinyu diagnosticaccuracyofcontrastenhancedultrasoundsynchronizedwithshearwaveelastographyinthedifferentialdiagnosisofbenignandmalignantbreastlesionsadiagnostictest
AT luoyunkai diagnosticaccuracyofcontrastenhancedultrasoundsynchronizedwithshearwaveelastographyinthedifferentialdiagnosisofbenignandmalignantbreastlesionsadiagnostictest
AT chenjian diagnosticaccuracyofcontrastenhancedultrasoundsynchronizedwithshearwaveelastographyinthedifferentialdiagnosisofbenignandmalignantbreastlesionsadiagnostictest