Cargando…

Feasibility of concomitant exclusion of left atrial appendage during novel transapical off-pump beating heart mitral valve repair

The AtriClip device enables the safe and reproducible epicardial clipping of the left atrial appendage. Transapical off-pump beating heart mitral valve repair using NeoChord DS100 Artificial Chordae Delivery System has matured and become more standardized. We aim to evaluate the feasibility of combi...

Descripción completa

Detalles Bibliográficos
Autores principales: Chan, Daniel Tai-Leung, Bhatia, Inderjeet, Lam, Simon Chi-Cheung, Au, Timmy Wing-Kuk
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Nature Singapore 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9907196/
https://www.ncbi.nlm.nih.gov/pubmed/36752993
http://dx.doi.org/10.1007/s10047-023-01383-2
_version_ 1784884125876879360
author Chan, Daniel Tai-Leung
Bhatia, Inderjeet
Lam, Simon Chi-Cheung
Au, Timmy Wing-Kuk
author_facet Chan, Daniel Tai-Leung
Bhatia, Inderjeet
Lam, Simon Chi-Cheung
Au, Timmy Wing-Kuk
author_sort Chan, Daniel Tai-Leung
collection PubMed
description The AtriClip device enables the safe and reproducible epicardial clipping of the left atrial appendage. Transapical off-pump beating heart mitral valve repair using NeoChord DS100 Artificial Chordae Delivery System has matured and become more standardized. We aim to evaluate the feasibility of combining NeoChord repair and left atrial appendage exclusion in a single procedure through the same minithoracotomy in patients with mitral valve prolapse and atrial fibrillation. From 2018 to 2019, seven patients with severe mitral regurgitation and atrial fibrillation underwent transesophageal echocardiography-guided transapical off-pump mitral valve repair with the novel NeoChord DS 1000 system and concomitant left atrial appendage exclusion using the AtriClip Pro II device. Both procedures were performed via left mini-thoracotomy. The AtriClip device was applied after the NeoChord repair was done. All seven patients had less than moderate mitral regurgitation after the NeoChord repair and successful left atrial appendage occlusion. There were no device or procedure-related complications. Clinical follow-up revealed significant symptomatic improvement, and no cardiovascular complications were reported. Transesophageal echocardiography at 6–12 months post-procedure showed stable left atrial appendage occlusion with no residual flow between the left atrium and the left atrial appendage and a stump of less than 5 mm. Beating heart epicardial clipping of the left atrial appendage using AtriClip concomitant with transapical mitral valve repair using Neochord DS 1000 system is a feasible and safe treatment option in mitral valve prolapse and atrial fibrillation in patients with limited indications. However, its safety needs to be confirmed in a larger series of patients. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s10047-023-01383-2.
format Online
Article
Text
id pubmed-9907196
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Springer Nature Singapore
record_format MEDLINE/PubMed
spelling pubmed-99071962023-02-09 Feasibility of concomitant exclusion of left atrial appendage during novel transapical off-pump beating heart mitral valve repair Chan, Daniel Tai-Leung Bhatia, Inderjeet Lam, Simon Chi-Cheung Au, Timmy Wing-Kuk J Artif Organs Original Article The AtriClip device enables the safe and reproducible epicardial clipping of the left atrial appendage. Transapical off-pump beating heart mitral valve repair using NeoChord DS100 Artificial Chordae Delivery System has matured and become more standardized. We aim to evaluate the feasibility of combining NeoChord repair and left atrial appendage exclusion in a single procedure through the same minithoracotomy in patients with mitral valve prolapse and atrial fibrillation. From 2018 to 2019, seven patients with severe mitral regurgitation and atrial fibrillation underwent transesophageal echocardiography-guided transapical off-pump mitral valve repair with the novel NeoChord DS 1000 system and concomitant left atrial appendage exclusion using the AtriClip Pro II device. Both procedures were performed via left mini-thoracotomy. The AtriClip device was applied after the NeoChord repair was done. All seven patients had less than moderate mitral regurgitation after the NeoChord repair and successful left atrial appendage occlusion. There were no device or procedure-related complications. Clinical follow-up revealed significant symptomatic improvement, and no cardiovascular complications were reported. Transesophageal echocardiography at 6–12 months post-procedure showed stable left atrial appendage occlusion with no residual flow between the left atrium and the left atrial appendage and a stump of less than 5 mm. Beating heart epicardial clipping of the left atrial appendage using AtriClip concomitant with transapical mitral valve repair using Neochord DS 1000 system is a feasible and safe treatment option in mitral valve prolapse and atrial fibrillation in patients with limited indications. However, its safety needs to be confirmed in a larger series of patients. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s10047-023-01383-2. Springer Nature Singapore 2023-02-08 /pmc/articles/PMC9907196/ /pubmed/36752993 http://dx.doi.org/10.1007/s10047-023-01383-2 Text en © The Japanese Society for Artificial Organs 2023, Springer Nature or its licensor (e.g. a society or other partner) holds exclusive rights to this article under a publishing agreement with the author(s) or other rightsholder(s); author self-archiving of the accepted manuscript version of this article is solely governed by the terms of such publishing agreement and applicable law. This article is made available via the PMC Open Access Subset for unrestricted research re-use and secondary analysis in any form or by any means with acknowledgement of the original source. These permissions are granted for the duration of the World Health Organization (WHO) declaration of COVID-19 as a global pandemic.
spellingShingle Original Article
Chan, Daniel Tai-Leung
Bhatia, Inderjeet
Lam, Simon Chi-Cheung
Au, Timmy Wing-Kuk
Feasibility of concomitant exclusion of left atrial appendage during novel transapical off-pump beating heart mitral valve repair
title Feasibility of concomitant exclusion of left atrial appendage during novel transapical off-pump beating heart mitral valve repair
title_full Feasibility of concomitant exclusion of left atrial appendage during novel transapical off-pump beating heart mitral valve repair
title_fullStr Feasibility of concomitant exclusion of left atrial appendage during novel transapical off-pump beating heart mitral valve repair
title_full_unstemmed Feasibility of concomitant exclusion of left atrial appendage during novel transapical off-pump beating heart mitral valve repair
title_short Feasibility of concomitant exclusion of left atrial appendage during novel transapical off-pump beating heart mitral valve repair
title_sort feasibility of concomitant exclusion of left atrial appendage during novel transapical off-pump beating heart mitral valve repair
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9907196/
https://www.ncbi.nlm.nih.gov/pubmed/36752993
http://dx.doi.org/10.1007/s10047-023-01383-2
work_keys_str_mv AT chandanieltaileung feasibilityofconcomitantexclusionofleftatrialappendageduringnoveltransapicaloffpumpbeatingheartmitralvalverepair
AT bhatiainderjeet feasibilityofconcomitantexclusionofleftatrialappendageduringnoveltransapicaloffpumpbeatingheartmitralvalverepair
AT lamsimonchicheung feasibilityofconcomitantexclusionofleftatrialappendageduringnoveltransapicaloffpumpbeatingheartmitralvalverepair
AT autimmywingkuk feasibilityofconcomitantexclusionofleftatrialappendageduringnoveltransapicaloffpumpbeatingheartmitralvalverepair