Cargando…

Skin biomechanical and viscoelastic properties measured with MyotonPRO in different areas of human body

BACKGROUND: There is still a lack of clinically practical device, which allows to perform rapid and accurate examination of the skin condition. For this reason, suitability of the MyotonPRO for the assessment of skin biomechanical and viscoelastic parameters was evaluated in this study. The aim of t...

Descripción completa

Detalles Bibliográficos
Autores principales: Rosicka, Katarzyna, Mierzejewska‐Krzyżowska, Barbara, Mrówczyński, Włodzimierz
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9907614/
https://www.ncbi.nlm.nih.gov/pubmed/34751466
http://dx.doi.org/10.1111/srt.13116
_version_ 1784884206406467584
author Rosicka, Katarzyna
Mierzejewska‐Krzyżowska, Barbara
Mrówczyński, Włodzimierz
author_facet Rosicka, Katarzyna
Mierzejewska‐Krzyżowska, Barbara
Mrówczyński, Włodzimierz
author_sort Rosicka, Katarzyna
collection PubMed
description BACKGROUND: There is still a lack of clinically practical device, which allows to perform rapid and accurate examination of the skin condition. For this reason, suitability of the MyotonPRO for the assessment of skin biomechanical and viscoelastic parameters was evaluated in this study. The aim of the study was to establish the reference values of five parameters measured by MyotonPRO various locations of human skin. MATERIALS AND METHODS: Oscillation frequency, dynamic stiffness, logarithmic decrement, mechanical stress relaxation and creep were measured at three different skin locations (clavicula, volar forearm and shin), using L‐shape short and medium arm probes in 32 young female volunteers. Mean values of obtained parameters recorded by both probes were compared among three skin locations while reliabilities of measurements were assessed. Additionally, relationships between all recorded parameters were examined RESULTS: There were no statistically significant differences between the mean values of five measured parameters obtained with both probes in all investigated areas. However, statistically significant differences of mean values of almost all parameters measured among three places examined were found. Despite considerable differences in mean values of obtained parameters, there were visible strong correlations between some studied parameters in all three investigated areas of skin. CONCLUSION: It was demonstrated in all locations studied that the higher value of oscillation frequency corresponds to the higher value of dynamic stiffness, moreover such tissue recovers faster to its initial shape, and it was characterized by lower creep values. Such results indicate the existence of identical relationships between the same studied parameters in different areas of skin.
format Online
Article
Text
id pubmed-9907614
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-99076142023-04-13 Skin biomechanical and viscoelastic properties measured with MyotonPRO in different areas of human body Rosicka, Katarzyna Mierzejewska‐Krzyżowska, Barbara Mrówczyński, Włodzimierz Skin Res Technol Original Articles BACKGROUND: There is still a lack of clinically practical device, which allows to perform rapid and accurate examination of the skin condition. For this reason, suitability of the MyotonPRO for the assessment of skin biomechanical and viscoelastic parameters was evaluated in this study. The aim of the study was to establish the reference values of five parameters measured by MyotonPRO various locations of human skin. MATERIALS AND METHODS: Oscillation frequency, dynamic stiffness, logarithmic decrement, mechanical stress relaxation and creep were measured at three different skin locations (clavicula, volar forearm and shin), using L‐shape short and medium arm probes in 32 young female volunteers. Mean values of obtained parameters recorded by both probes were compared among three skin locations while reliabilities of measurements were assessed. Additionally, relationships between all recorded parameters were examined RESULTS: There were no statistically significant differences between the mean values of five measured parameters obtained with both probes in all investigated areas. However, statistically significant differences of mean values of almost all parameters measured among three places examined were found. Despite considerable differences in mean values of obtained parameters, there were visible strong correlations between some studied parameters in all three investigated areas of skin. CONCLUSION: It was demonstrated in all locations studied that the higher value of oscillation frequency corresponds to the higher value of dynamic stiffness, moreover such tissue recovers faster to its initial shape, and it was characterized by lower creep values. Such results indicate the existence of identical relationships between the same studied parameters in different areas of skin. John Wiley and Sons Inc. 2021-11-09 /pmc/articles/PMC9907614/ /pubmed/34751466 http://dx.doi.org/10.1111/srt.13116 Text en © 2021 The Authors. Skin Research and Technology published by John Wiley & Sons Ltd. https://creativecommons.org/licenses/by/4.0/This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Articles
Rosicka, Katarzyna
Mierzejewska‐Krzyżowska, Barbara
Mrówczyński, Włodzimierz
Skin biomechanical and viscoelastic properties measured with MyotonPRO in different areas of human body
title Skin biomechanical and viscoelastic properties measured with MyotonPRO in different areas of human body
title_full Skin biomechanical and viscoelastic properties measured with MyotonPRO in different areas of human body
title_fullStr Skin biomechanical and viscoelastic properties measured with MyotonPRO in different areas of human body
title_full_unstemmed Skin biomechanical and viscoelastic properties measured with MyotonPRO in different areas of human body
title_short Skin biomechanical and viscoelastic properties measured with MyotonPRO in different areas of human body
title_sort skin biomechanical and viscoelastic properties measured with myotonpro in different areas of human body
topic Original Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9907614/
https://www.ncbi.nlm.nih.gov/pubmed/34751466
http://dx.doi.org/10.1111/srt.13116
work_keys_str_mv AT rosickakatarzyna skinbiomechanicalandviscoelasticpropertiesmeasuredwithmyotonproindifferentareasofhumanbody
AT mierzejewskakrzyzowskabarbara skinbiomechanicalandviscoelasticpropertiesmeasuredwithmyotonproindifferentareasofhumanbody
AT mrowczynskiwłodzimierz skinbiomechanicalandviscoelasticpropertiesmeasuredwithmyotonproindifferentareasofhumanbody