Cargando…

Comparison of deep learning-based denoising methods in cardiac SPECT

BACKGROUND: Myocardial perfusion SPECT (MPS) images often suffer from artefacts caused by low-count statistics. Poor-quality images can lead to misinterpretations of perfusion defects. Deep learning (DL)-based methods have been proposed to overcome the noise artefacts. The aim of this study was to i...

Descripción completa

Detalles Bibliográficos
Autores principales: Sohlberg, Antti, Kangasmaa, Tuija, Constable, Chris, Tikkakoski, Antti
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer International Publishing 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9908801/
https://www.ncbi.nlm.nih.gov/pubmed/36752847
http://dx.doi.org/10.1186/s40658-023-00531-0
_version_ 1784884439050878976
author Sohlberg, Antti
Kangasmaa, Tuija
Constable, Chris
Tikkakoski, Antti
author_facet Sohlberg, Antti
Kangasmaa, Tuija
Constable, Chris
Tikkakoski, Antti
author_sort Sohlberg, Antti
collection PubMed
description BACKGROUND: Myocardial perfusion SPECT (MPS) images often suffer from artefacts caused by low-count statistics. Poor-quality images can lead to misinterpretations of perfusion defects. Deep learning (DL)-based methods have been proposed to overcome the noise artefacts. The aim of this study was to investigate the differences among several DL denoising models. METHODS: Convolution neural network (CNN), residual neural network (RES), UNET and conditional generative adversarial neural network (cGAN) were generated and trained using ordered subsets expectation maximization (OSEM) reconstructed MPS studies acquired with full, half, three-eighths and quarter acquisition time. All DL methods were compared against each other and also against images without DL-based denoising. Comparisons were made using half and quarter time acquisition data. The methods were evaluated in terms of noise level (coefficient of variation of counts, CoV), structural similarity index measure (SSIM) in the myocardium of normal patients and receiver operating characteristic (ROC) analysis of realistic artificial perfusion defects inserted into normal MPS scans. Total perfusion deficit scores were used as observer rating for the presence of a perfusion defect. RESULTS: All the DL denoising methods tested provided statistically significantly lower noise level than OSEM without DL-based denoising with the same acquisition time. CoV of the myocardium counts with the different DL noising methods was on average 7% (CNN), 8% (RES), 7% (UNET) and 14% (cGAN) lower than with OSEM. All DL methods also outperformed full time OSEM without DL-based denoising in terms of noise level with both half and quarter acquisition time, but this difference was not statistically significant. cGAN had the lowest CoV of the DL methods at all noise levels. Image quality and polar map uniformity of DL-denoised images were also better than reduced acquisition time OSEM’s. SSIM of the reduced acquisition time OSEM was overall higher than with the DL methods. The defect detection performance of full time OSEM measured as area under the ROC curve (AUC) was on average 0.97. Half time OSEM, CNN, RES and UNET provided equal or nearly equal AUC. However, with quarter time data CNN, RES and UNET had an average AUC of 0.93, which was lower than full time OSEM’s AUC, but equal to quarter acquisition time OSEM. cGAN did not achieve the defect detection performance of the other DL methods. Its average AUC with half time data was 0.94 and 0.91 with quarter time data. CONCLUSIONS: DL-based denoising effectively improved noise level with slightly lower perfusion defect detection performance than full time reconstruction. cGAN achieved the lowest noise level, but at the same time the poorest defect detection performance among the studied DL methods.
format Online
Article
Text
id pubmed-9908801
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Springer International Publishing
record_format MEDLINE/PubMed
spelling pubmed-99088012023-02-10 Comparison of deep learning-based denoising methods in cardiac SPECT Sohlberg, Antti Kangasmaa, Tuija Constable, Chris Tikkakoski, Antti EJNMMI Phys Original Research BACKGROUND: Myocardial perfusion SPECT (MPS) images often suffer from artefacts caused by low-count statistics. Poor-quality images can lead to misinterpretations of perfusion defects. Deep learning (DL)-based methods have been proposed to overcome the noise artefacts. The aim of this study was to investigate the differences among several DL denoising models. METHODS: Convolution neural network (CNN), residual neural network (RES), UNET and conditional generative adversarial neural network (cGAN) were generated and trained using ordered subsets expectation maximization (OSEM) reconstructed MPS studies acquired with full, half, three-eighths and quarter acquisition time. All DL methods were compared against each other and also against images without DL-based denoising. Comparisons were made using half and quarter time acquisition data. The methods were evaluated in terms of noise level (coefficient of variation of counts, CoV), structural similarity index measure (SSIM) in the myocardium of normal patients and receiver operating characteristic (ROC) analysis of realistic artificial perfusion defects inserted into normal MPS scans. Total perfusion deficit scores were used as observer rating for the presence of a perfusion defect. RESULTS: All the DL denoising methods tested provided statistically significantly lower noise level than OSEM without DL-based denoising with the same acquisition time. CoV of the myocardium counts with the different DL noising methods was on average 7% (CNN), 8% (RES), 7% (UNET) and 14% (cGAN) lower than with OSEM. All DL methods also outperformed full time OSEM without DL-based denoising in terms of noise level with both half and quarter acquisition time, but this difference was not statistically significant. cGAN had the lowest CoV of the DL methods at all noise levels. Image quality and polar map uniformity of DL-denoised images were also better than reduced acquisition time OSEM’s. SSIM of the reduced acquisition time OSEM was overall higher than with the DL methods. The defect detection performance of full time OSEM measured as area under the ROC curve (AUC) was on average 0.97. Half time OSEM, CNN, RES and UNET provided equal or nearly equal AUC. However, with quarter time data CNN, RES and UNET had an average AUC of 0.93, which was lower than full time OSEM’s AUC, but equal to quarter acquisition time OSEM. cGAN did not achieve the defect detection performance of the other DL methods. Its average AUC with half time data was 0.94 and 0.91 with quarter time data. CONCLUSIONS: DL-based denoising effectively improved noise level with slightly lower perfusion defect detection performance than full time reconstruction. cGAN achieved the lowest noise level, but at the same time the poorest defect detection performance among the studied DL methods. Springer International Publishing 2023-02-08 /pmc/articles/PMC9908801/ /pubmed/36752847 http://dx.doi.org/10.1186/s40658-023-00531-0 Text en © The Author(s) 2023, corrected publication 2023 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Original Research
Sohlberg, Antti
Kangasmaa, Tuija
Constable, Chris
Tikkakoski, Antti
Comparison of deep learning-based denoising methods in cardiac SPECT
title Comparison of deep learning-based denoising methods in cardiac SPECT
title_full Comparison of deep learning-based denoising methods in cardiac SPECT
title_fullStr Comparison of deep learning-based denoising methods in cardiac SPECT
title_full_unstemmed Comparison of deep learning-based denoising methods in cardiac SPECT
title_short Comparison of deep learning-based denoising methods in cardiac SPECT
title_sort comparison of deep learning-based denoising methods in cardiac spect
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9908801/
https://www.ncbi.nlm.nih.gov/pubmed/36752847
http://dx.doi.org/10.1186/s40658-023-00531-0
work_keys_str_mv AT sohlbergantti comparisonofdeeplearningbaseddenoisingmethodsincardiacspect
AT kangasmaatuija comparisonofdeeplearningbaseddenoisingmethodsincardiacspect
AT constablechris comparisonofdeeplearningbaseddenoisingmethodsincardiacspect
AT tikkakoskiantti comparisonofdeeplearningbaseddenoisingmethodsincardiacspect