Cargando…

Sensitivity and specificity for detecting pseudotumors in patients with hip resurfacing arthroplasty, metal-on-metal or metal-on-polyethylene total hip arthroplasty—MRI versus ultrasonography performed by an orthopedic surgery resident

BACKGROUND: Metal artifact reduction sequence magnetic resonance imaging (MRI) scan is a common method to detect adverse reaction to metal debris in total hip arthroplasty (THA). It might be quicker and cheaper if ultrasonography (US) could screen for the need for an MRI. However, both require train...

Descripción completa

Detalles Bibliográficos
Autores principales: Mikkelsen, Rasmus T, Schou, Martin, Torfing, Trine, Graumann, Ole, Overgaard, Søren, Varnum, Claus
Formato: Online Artículo Texto
Lenguaje:English
Publicado: SAGE Publications 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9909072/
https://www.ncbi.nlm.nih.gov/pubmed/36776533
http://dx.doi.org/10.1177/20584601231152396
_version_ 1784884490945953792
author Mikkelsen, Rasmus T
Schou, Martin
Torfing, Trine
Graumann, Ole
Overgaard, Søren
Varnum, Claus
author_facet Mikkelsen, Rasmus T
Schou, Martin
Torfing, Trine
Graumann, Ole
Overgaard, Søren
Varnum, Claus
author_sort Mikkelsen, Rasmus T
collection PubMed
description BACKGROUND: Metal artifact reduction sequence magnetic resonance imaging (MRI) scan is a common method to detect adverse reaction to metal debris in total hip arthroplasty (THA). It might be quicker and cheaper if ultrasonography (US) could screen for the need for an MRI. However, both require trained personnel. PURPOSE: We aimed to investigate the sensitivity and specificity of US for detecting pseudotumors (PT) when performed by an orthopedic surgery resident compared to MRI. We also investigated the sensitivity and specificity of US to detect PTs in obese and non-obese patients. MATERIAL AND METHODS: We examined 205 patients with hip resurfacing arthroplasty, metal-on-metal or metal-on-polyethylene THA with both MRI and US. US was performed by an orthopedic surgery resident who was trained according to a standardized training program in musculoskeletal US. Results from MRI were used as gold standard. RESULTS: US had a sensitivity of 0.92 (95% CI 0.81–0.98) and specificity of 0.94 (95% CI 0.89–0.97) for detecting PT. It had a positive predictive value of 0.84 (95% CI 0.73–0.91) and a negative predictive value of 0.97 (95% CI 0.93–0.99). US performed similarly in obese and non-obese patients. CONCLUSIONS: US had a high sensitivity and specificity for detecting PT when performed by an orthopedic surgery resident. Trained orthopedic surgeons could screen for the need of an MRI scan when searching PTs.
format Online
Article
Text
id pubmed-9909072
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher SAGE Publications
record_format MEDLINE/PubMed
spelling pubmed-99090722023-02-10 Sensitivity and specificity for detecting pseudotumors in patients with hip resurfacing arthroplasty, metal-on-metal or metal-on-polyethylene total hip arthroplasty—MRI versus ultrasonography performed by an orthopedic surgery resident Mikkelsen, Rasmus T Schou, Martin Torfing, Trine Graumann, Ole Overgaard, Søren Varnum, Claus Acta Radiol Open Original Article BACKGROUND: Metal artifact reduction sequence magnetic resonance imaging (MRI) scan is a common method to detect adverse reaction to metal debris in total hip arthroplasty (THA). It might be quicker and cheaper if ultrasonography (US) could screen for the need for an MRI. However, both require trained personnel. PURPOSE: We aimed to investigate the sensitivity and specificity of US for detecting pseudotumors (PT) when performed by an orthopedic surgery resident compared to MRI. We also investigated the sensitivity and specificity of US to detect PTs in obese and non-obese patients. MATERIAL AND METHODS: We examined 205 patients with hip resurfacing arthroplasty, metal-on-metal or metal-on-polyethylene THA with both MRI and US. US was performed by an orthopedic surgery resident who was trained according to a standardized training program in musculoskeletal US. Results from MRI were used as gold standard. RESULTS: US had a sensitivity of 0.92 (95% CI 0.81–0.98) and specificity of 0.94 (95% CI 0.89–0.97) for detecting PT. It had a positive predictive value of 0.84 (95% CI 0.73–0.91) and a negative predictive value of 0.97 (95% CI 0.93–0.99). US performed similarly in obese and non-obese patients. CONCLUSIONS: US had a high sensitivity and specificity for detecting PT when performed by an orthopedic surgery resident. Trained orthopedic surgeons could screen for the need of an MRI scan when searching PTs. SAGE Publications 2023-02-08 /pmc/articles/PMC9909072/ /pubmed/36776533 http://dx.doi.org/10.1177/20584601231152396 Text en © The Author(s) 2023 https://creativecommons.org/licenses/by-nc/4.0/This article is distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 License (https://creativecommons.org/licenses/by-nc/4.0/) which permits non-commercial use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access pages (https://us.sagepub.com/en-us/nam/open-access-at-sage).
spellingShingle Original Article
Mikkelsen, Rasmus T
Schou, Martin
Torfing, Trine
Graumann, Ole
Overgaard, Søren
Varnum, Claus
Sensitivity and specificity for detecting pseudotumors in patients with hip resurfacing arthroplasty, metal-on-metal or metal-on-polyethylene total hip arthroplasty—MRI versus ultrasonography performed by an orthopedic surgery resident
title Sensitivity and specificity for detecting pseudotumors in patients with hip resurfacing arthroplasty, metal-on-metal or metal-on-polyethylene total hip arthroplasty—MRI versus ultrasonography performed by an orthopedic surgery resident
title_full Sensitivity and specificity for detecting pseudotumors in patients with hip resurfacing arthroplasty, metal-on-metal or metal-on-polyethylene total hip arthroplasty—MRI versus ultrasonography performed by an orthopedic surgery resident
title_fullStr Sensitivity and specificity for detecting pseudotumors in patients with hip resurfacing arthroplasty, metal-on-metal or metal-on-polyethylene total hip arthroplasty—MRI versus ultrasonography performed by an orthopedic surgery resident
title_full_unstemmed Sensitivity and specificity for detecting pseudotumors in patients with hip resurfacing arthroplasty, metal-on-metal or metal-on-polyethylene total hip arthroplasty—MRI versus ultrasonography performed by an orthopedic surgery resident
title_short Sensitivity and specificity for detecting pseudotumors in patients with hip resurfacing arthroplasty, metal-on-metal or metal-on-polyethylene total hip arthroplasty—MRI versus ultrasonography performed by an orthopedic surgery resident
title_sort sensitivity and specificity for detecting pseudotumors in patients with hip resurfacing arthroplasty, metal-on-metal or metal-on-polyethylene total hip arthroplasty—mri versus ultrasonography performed by an orthopedic surgery resident
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9909072/
https://www.ncbi.nlm.nih.gov/pubmed/36776533
http://dx.doi.org/10.1177/20584601231152396
work_keys_str_mv AT mikkelsenrasmust sensitivityandspecificityfordetectingpseudotumorsinpatientswithhipresurfacingarthroplastymetalonmetalormetalonpolyethylenetotalhiparthroplastymriversusultrasonographyperformedbyanorthopedicsurgeryresident
AT schoumartin sensitivityandspecificityfordetectingpseudotumorsinpatientswithhipresurfacingarthroplastymetalonmetalormetalonpolyethylenetotalhiparthroplastymriversusultrasonographyperformedbyanorthopedicsurgeryresident
AT torfingtrine sensitivityandspecificityfordetectingpseudotumorsinpatientswithhipresurfacingarthroplastymetalonmetalormetalonpolyethylenetotalhiparthroplastymriversusultrasonographyperformedbyanorthopedicsurgeryresident
AT graumannole sensitivityandspecificityfordetectingpseudotumorsinpatientswithhipresurfacingarthroplastymetalonmetalormetalonpolyethylenetotalhiparthroplastymriversusultrasonographyperformedbyanorthopedicsurgeryresident
AT overgaardsøren sensitivityandspecificityfordetectingpseudotumorsinpatientswithhipresurfacingarthroplastymetalonmetalormetalonpolyethylenetotalhiparthroplastymriversusultrasonographyperformedbyanorthopedicsurgeryresident
AT varnumclaus sensitivityandspecificityfordetectingpseudotumorsinpatientswithhipresurfacingarthroplastymetalonmetalormetalonpolyethylenetotalhiparthroplastymriversusultrasonographyperformedbyanorthopedicsurgeryresident