Cargando…
Sensitivity and specificity for detecting pseudotumors in patients with hip resurfacing arthroplasty, metal-on-metal or metal-on-polyethylene total hip arthroplasty—MRI versus ultrasonography performed by an orthopedic surgery resident
BACKGROUND: Metal artifact reduction sequence magnetic resonance imaging (MRI) scan is a common method to detect adverse reaction to metal debris in total hip arthroplasty (THA). It might be quicker and cheaper if ultrasonography (US) could screen for the need for an MRI. However, both require train...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
SAGE Publications
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9909072/ https://www.ncbi.nlm.nih.gov/pubmed/36776533 http://dx.doi.org/10.1177/20584601231152396 |
_version_ | 1784884490945953792 |
---|---|
author | Mikkelsen, Rasmus T Schou, Martin Torfing, Trine Graumann, Ole Overgaard, Søren Varnum, Claus |
author_facet | Mikkelsen, Rasmus T Schou, Martin Torfing, Trine Graumann, Ole Overgaard, Søren Varnum, Claus |
author_sort | Mikkelsen, Rasmus T |
collection | PubMed |
description | BACKGROUND: Metal artifact reduction sequence magnetic resonance imaging (MRI) scan is a common method to detect adverse reaction to metal debris in total hip arthroplasty (THA). It might be quicker and cheaper if ultrasonography (US) could screen for the need for an MRI. However, both require trained personnel. PURPOSE: We aimed to investigate the sensitivity and specificity of US for detecting pseudotumors (PT) when performed by an orthopedic surgery resident compared to MRI. We also investigated the sensitivity and specificity of US to detect PTs in obese and non-obese patients. MATERIAL AND METHODS: We examined 205 patients with hip resurfacing arthroplasty, metal-on-metal or metal-on-polyethylene THA with both MRI and US. US was performed by an orthopedic surgery resident who was trained according to a standardized training program in musculoskeletal US. Results from MRI were used as gold standard. RESULTS: US had a sensitivity of 0.92 (95% CI 0.81–0.98) and specificity of 0.94 (95% CI 0.89–0.97) for detecting PT. It had a positive predictive value of 0.84 (95% CI 0.73–0.91) and a negative predictive value of 0.97 (95% CI 0.93–0.99). US performed similarly in obese and non-obese patients. CONCLUSIONS: US had a high sensitivity and specificity for detecting PT when performed by an orthopedic surgery resident. Trained orthopedic surgeons could screen for the need of an MRI scan when searching PTs. |
format | Online Article Text |
id | pubmed-9909072 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | SAGE Publications |
record_format | MEDLINE/PubMed |
spelling | pubmed-99090722023-02-10 Sensitivity and specificity for detecting pseudotumors in patients with hip resurfacing arthroplasty, metal-on-metal or metal-on-polyethylene total hip arthroplasty—MRI versus ultrasonography performed by an orthopedic surgery resident Mikkelsen, Rasmus T Schou, Martin Torfing, Trine Graumann, Ole Overgaard, Søren Varnum, Claus Acta Radiol Open Original Article BACKGROUND: Metal artifact reduction sequence magnetic resonance imaging (MRI) scan is a common method to detect adverse reaction to metal debris in total hip arthroplasty (THA). It might be quicker and cheaper if ultrasonography (US) could screen for the need for an MRI. However, both require trained personnel. PURPOSE: We aimed to investigate the sensitivity and specificity of US for detecting pseudotumors (PT) when performed by an orthopedic surgery resident compared to MRI. We also investigated the sensitivity and specificity of US to detect PTs in obese and non-obese patients. MATERIAL AND METHODS: We examined 205 patients with hip resurfacing arthroplasty, metal-on-metal or metal-on-polyethylene THA with both MRI and US. US was performed by an orthopedic surgery resident who was trained according to a standardized training program in musculoskeletal US. Results from MRI were used as gold standard. RESULTS: US had a sensitivity of 0.92 (95% CI 0.81–0.98) and specificity of 0.94 (95% CI 0.89–0.97) for detecting PT. It had a positive predictive value of 0.84 (95% CI 0.73–0.91) and a negative predictive value of 0.97 (95% CI 0.93–0.99). US performed similarly in obese and non-obese patients. CONCLUSIONS: US had a high sensitivity and specificity for detecting PT when performed by an orthopedic surgery resident. Trained orthopedic surgeons could screen for the need of an MRI scan when searching PTs. SAGE Publications 2023-02-08 /pmc/articles/PMC9909072/ /pubmed/36776533 http://dx.doi.org/10.1177/20584601231152396 Text en © The Author(s) 2023 https://creativecommons.org/licenses/by-nc/4.0/This article is distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 License (https://creativecommons.org/licenses/by-nc/4.0/) which permits non-commercial use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access pages (https://us.sagepub.com/en-us/nam/open-access-at-sage). |
spellingShingle | Original Article Mikkelsen, Rasmus T Schou, Martin Torfing, Trine Graumann, Ole Overgaard, Søren Varnum, Claus Sensitivity and specificity for detecting pseudotumors in patients with hip resurfacing arthroplasty, metal-on-metal or metal-on-polyethylene total hip arthroplasty—MRI versus ultrasonography performed by an orthopedic surgery resident |
title | Sensitivity and specificity for detecting pseudotumors in patients with hip resurfacing arthroplasty, metal-on-metal or metal-on-polyethylene total hip arthroplasty—MRI versus ultrasonography performed by an orthopedic surgery resident |
title_full | Sensitivity and specificity for detecting pseudotumors in patients with hip resurfacing arthroplasty, metal-on-metal or metal-on-polyethylene total hip arthroplasty—MRI versus ultrasonography performed by an orthopedic surgery resident |
title_fullStr | Sensitivity and specificity for detecting pseudotumors in patients with hip resurfacing arthroplasty, metal-on-metal or metal-on-polyethylene total hip arthroplasty—MRI versus ultrasonography performed by an orthopedic surgery resident |
title_full_unstemmed | Sensitivity and specificity for detecting pseudotumors in patients with hip resurfacing arthroplasty, metal-on-metal or metal-on-polyethylene total hip arthroplasty—MRI versus ultrasonography performed by an orthopedic surgery resident |
title_short | Sensitivity and specificity for detecting pseudotumors in patients with hip resurfacing arthroplasty, metal-on-metal or metal-on-polyethylene total hip arthroplasty—MRI versus ultrasonography performed by an orthopedic surgery resident |
title_sort | sensitivity and specificity for detecting pseudotumors in patients with hip resurfacing arthroplasty, metal-on-metal or metal-on-polyethylene total hip arthroplasty—mri versus ultrasonography performed by an orthopedic surgery resident |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9909072/ https://www.ncbi.nlm.nih.gov/pubmed/36776533 http://dx.doi.org/10.1177/20584601231152396 |
work_keys_str_mv | AT mikkelsenrasmust sensitivityandspecificityfordetectingpseudotumorsinpatientswithhipresurfacingarthroplastymetalonmetalormetalonpolyethylenetotalhiparthroplastymriversusultrasonographyperformedbyanorthopedicsurgeryresident AT schoumartin sensitivityandspecificityfordetectingpseudotumorsinpatientswithhipresurfacingarthroplastymetalonmetalormetalonpolyethylenetotalhiparthroplastymriversusultrasonographyperformedbyanorthopedicsurgeryresident AT torfingtrine sensitivityandspecificityfordetectingpseudotumorsinpatientswithhipresurfacingarthroplastymetalonmetalormetalonpolyethylenetotalhiparthroplastymriversusultrasonographyperformedbyanorthopedicsurgeryresident AT graumannole sensitivityandspecificityfordetectingpseudotumorsinpatientswithhipresurfacingarthroplastymetalonmetalormetalonpolyethylenetotalhiparthroplastymriversusultrasonographyperformedbyanorthopedicsurgeryresident AT overgaardsøren sensitivityandspecificityfordetectingpseudotumorsinpatientswithhipresurfacingarthroplastymetalonmetalormetalonpolyethylenetotalhiparthroplastymriversusultrasonographyperformedbyanorthopedicsurgeryresident AT varnumclaus sensitivityandspecificityfordetectingpseudotumorsinpatientswithhipresurfacingarthroplastymetalonmetalormetalonpolyethylenetotalhiparthroplastymriversusultrasonographyperformedbyanorthopedicsurgeryresident |