Testing the circulation of expanded flaps—prevention of necrosis of expanded flaps (a clinic study)
BACKGROUND: Expanded flaps are commonly used in plastic surgery. Although expanded flaps are more resistant to hypoxia than unexpanded flaps, flap necrosis can sometimes occur, particularly with skin incisions of regular proportion. Distal skin necrosis of the expansion flap can be avoided by carefu...