Novel Capped-Needle Device: A Novel Safety Feature to Eliminate Air Bubbles in Hemodialysis

INTRODUCTION: Air bubbles in the dialysis circuit are rarely visible after automatic priming; however, they are often visible after the needles are manually connected to the circuit. To prevent this issue, we thought to prime needles with a circuit at automatic priming by the hemodialysis machine. I...

Descripción completa

Detalles Bibliográficos
Autores principales: Shibata, Kazuhiko, Shinzato, Takahiro, Toma, Shigeki, Nakai, Shigeru, Kobayashi, Yusuke, Hashimoto, Tatsuo, Tamura, Koichi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: S. Karger AG 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9909616/
https://www.ncbi.nlm.nih.gov/pubmed/35468597
http://dx.doi.org/10.1159/000524357
_version_ 1784884611354984448
author Shibata, Kazuhiko
Shinzato, Takahiro
Toma, Shigeki
Nakai, Shigeru
Kobayashi, Yusuke
Hashimoto, Tatsuo
Tamura, Koichi
author_facet Shibata, Kazuhiko
Shinzato, Takahiro
Toma, Shigeki
Nakai, Shigeru
Kobayashi, Yusuke
Hashimoto, Tatsuo
Tamura, Koichi
author_sort Shibata, Kazuhiko
collection PubMed
description INTRODUCTION: Air bubbles in the dialysis circuit are rarely visible after automatic priming; however, they are often visible after the needles are manually connected to the circuit. To prevent this issue, we thought to prime needles with a circuit at automatic priming by the hemodialysis machine. In order to achieve this idea, we designed and manufactured a novel capped needle to connect the needles to the extracorporeal circuit before the automatic priming of the hemodialysis machine. This study investigated the effectiveness of this novel capped needle and compared it with the conventional method for preventing air bubble contamination. METHODS: We tested novel capped needles ten times to evaluate whether the dialysis machine works appropriately and removes air bubbles even with the attached capped needle. Next, we performed 25 trials using the conventional method, in which skilled nurses manually connect the needle. In both methods, we thoroughly counted the air bubbles with our naked eyes. We predicted that the capped needle would leave few bubbles in the circuit. In order to evaluate fewer bubbles, we conducted an additional experiment using a microparticle counter to measure the size and number of the bubbles. RESULTS: We thoroughly searched for air bubbles during each of the ten tests but could not find any bubbles visible to the naked eye. In the conventional method, bubbles were visible in 29 out of 50 cases. The bubble count was significantly lower in the capped-needle method than in the conventional method (p < 0.0001, Pearson's χ<sup>2</sup> test). In the additional experiments using the microparticle counter, the average remaining air volume in the extracorporeal circuit was 0.0999 ± 0.2438 nL when the priming was performed using the novel capped needles. CONCLUSION: The novel capped needle eliminated all visible bubbles efficiently and effectively; therefore, it could be a valuable device for hemodialysis treatment. The reduction of air from the dialysis circuit may improve patient prognosis.
format Online
Article
Text
id pubmed-9909616
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher S. Karger AG
record_format MEDLINE/PubMed
spelling pubmed-99096162023-02-10 Novel Capped-Needle Device: A Novel Safety Feature to Eliminate Air Bubbles in Hemodialysis Shibata, Kazuhiko Shinzato, Takahiro Toma, Shigeki Nakai, Shigeru Kobayashi, Yusuke Hashimoto, Tatsuo Tamura, Koichi Blood Purif Hemodialysis − Research Article INTRODUCTION: Air bubbles in the dialysis circuit are rarely visible after automatic priming; however, they are often visible after the needles are manually connected to the circuit. To prevent this issue, we thought to prime needles with a circuit at automatic priming by the hemodialysis machine. In order to achieve this idea, we designed and manufactured a novel capped needle to connect the needles to the extracorporeal circuit before the automatic priming of the hemodialysis machine. This study investigated the effectiveness of this novel capped needle and compared it with the conventional method for preventing air bubble contamination. METHODS: We tested novel capped needles ten times to evaluate whether the dialysis machine works appropriately and removes air bubbles even with the attached capped needle. Next, we performed 25 trials using the conventional method, in which skilled nurses manually connect the needle. In both methods, we thoroughly counted the air bubbles with our naked eyes. We predicted that the capped needle would leave few bubbles in the circuit. In order to evaluate fewer bubbles, we conducted an additional experiment using a microparticle counter to measure the size and number of the bubbles. RESULTS: We thoroughly searched for air bubbles during each of the ten tests but could not find any bubbles visible to the naked eye. In the conventional method, bubbles were visible in 29 out of 50 cases. The bubble count was significantly lower in the capped-needle method than in the conventional method (p < 0.0001, Pearson's χ<sup>2</sup> test). In the additional experiments using the microparticle counter, the average remaining air volume in the extracorporeal circuit was 0.0999 ± 0.2438 nL when the priming was performed using the novel capped needles. CONCLUSION: The novel capped needle eliminated all visible bubbles efficiently and effectively; therefore, it could be a valuable device for hemodialysis treatment. The reduction of air from the dialysis circuit may improve patient prognosis. S. Karger AG 2023-01 2022-04-25 /pmc/articles/PMC9909616/ /pubmed/35468597 http://dx.doi.org/10.1159/000524357 Text en Copyright © 2022 by The Author(s). Published by S. Karger AG, Basel https://creativecommons.org/licenses/by-nc/4.0/This article is licensed under the Creative Commons Attribution-NonCommercial 4.0 International License (CC BY-NC). Usage and distribution for commercial purposes requires written permission.
spellingShingle Hemodialysis − Research Article
Shibata, Kazuhiko
Shinzato, Takahiro
Toma, Shigeki
Nakai, Shigeru
Kobayashi, Yusuke
Hashimoto, Tatsuo
Tamura, Koichi
Novel Capped-Needle Device: A Novel Safety Feature to Eliminate Air Bubbles in Hemodialysis
title Novel Capped-Needle Device: A Novel Safety Feature to Eliminate Air Bubbles in Hemodialysis
title_full Novel Capped-Needle Device: A Novel Safety Feature to Eliminate Air Bubbles in Hemodialysis
title_fullStr Novel Capped-Needle Device: A Novel Safety Feature to Eliminate Air Bubbles in Hemodialysis
title_full_unstemmed Novel Capped-Needle Device: A Novel Safety Feature to Eliminate Air Bubbles in Hemodialysis
title_short Novel Capped-Needle Device: A Novel Safety Feature to Eliminate Air Bubbles in Hemodialysis
title_sort novel capped-needle device: a novel safety feature to eliminate air bubbles in hemodialysis
topic Hemodialysis − Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9909616/
https://www.ncbi.nlm.nih.gov/pubmed/35468597
http://dx.doi.org/10.1159/000524357
work_keys_str_mv AT shibatakazuhiko novelcappedneedledeviceanovelsafetyfeaturetoeliminateairbubblesinhemodialysis
AT shinzatotakahiro novelcappedneedledeviceanovelsafetyfeaturetoeliminateairbubblesinhemodialysis
AT tomashigeki novelcappedneedledeviceanovelsafetyfeaturetoeliminateairbubblesinhemodialysis
AT nakaishigeru novelcappedneedledeviceanovelsafetyfeaturetoeliminateairbubblesinhemodialysis
AT kobayashiyusuke novelcappedneedledeviceanovelsafetyfeaturetoeliminateairbubblesinhemodialysis
AT hashimototatsuo novelcappedneedledeviceanovelsafetyfeaturetoeliminateairbubblesinhemodialysis
AT tamurakoichi novelcappedneedledeviceanovelsafetyfeaturetoeliminateairbubblesinhemodialysis