Cargando…
No clinical difference at mid-term follow-up between TiN-coated versus uncoated cemented mobile-bearing total knee arthroplasty: a matched cohort study
Introduction: Nitride-based ceramic coating was introduced into surgical implants to improve hardness, reduce abrasion, and decrease the risk of metal-induced adverse reactions, especially for patients with suspected or identified metal hypersensitivity. The study aimed to evaluate the effectiveness...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
EDP Sciences
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9910165/ https://www.ncbi.nlm.nih.gov/pubmed/36757220 http://dx.doi.org/10.1051/sicotj/2023001 |
Sumario: | Introduction: Nitride-based ceramic coating was introduced into surgical implants to improve hardness, reduce abrasion, and decrease the risk of metal-induced adverse reactions, especially for patients with suspected or identified metal hypersensitivity. The study aimed to evaluate the effectiveness and safety of a titanium nitride (TiN) coated prosthesis with a mobile bearing design. Methods: This was a retrospective matched-cohort study from a single center, comparing clinical outcomes between patients receiving either a TiN-coated versus an uncoated cobalt-chromium-molybdenum (CoCrMo) prostheses for primary total knee replacement. Seventeen patients received the TiN prosthesis between 2015 and 2019. These were matched 1:2 with patients receiving uncoated mobile-bearing knee prostheses with the same design manufacturer. Results: Fourteen patients in the TiN group had complete 5-year follow-up data and were compared with 34 patients from the CoCrMo group. The Knee Society Score was 170.6 ± 28.0 (Function subscore 83.7 ± 17.5 and Knee subscore 86.9 ± 13.8) in the TiN group and 180.7 ± 49.4 (Function subscore 87.5 ± 14.3 and Knee subscore 93.2 ± 9.6) in CoCrMo group, with no statistically significant difference (p = 0.19). One patient underwent a revision for instability requiring the removal of the implant in the TiN group and none in the CoCrMo group. The survival rates were 92.9% (CI95% 77.3–100.0) and 100.0% in the TiN group and CoCrMo group respectively (p = 1.0). Discussion: TiN-coated TKA with mobile bearing resulted in satisfactory clinical outcomes, and a low revision rate, and there was no complication related to the coated implant. The use of TiN-coated prostheses in case of confirmed or suspected metal allergy provides satisfactory short-term clinic outcomes. |
---|