Cargando…
Comparison of Corneal Densitometry and Visual Quality after Small Incision Lenticule Extraction (SMILE) and Laser Epithelial Keratomileusis (LASEK): One-Year Comparative Study
PURPOSE: To investigate changes in corneal densitometry (CD) and visual quality following small incision lenticule extraction (SMILE) and laser epithelial keratomileusis (LASEK) in patients with mild-to-moderate myopia. METHODS: A retrospective analysis was performed on 24 and 25 patients (46 eyes e...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9911227/ https://www.ncbi.nlm.nih.gov/pubmed/36778055 http://dx.doi.org/10.1155/2023/3430742 |
_version_ | 1784884948418691072 |
---|---|
author | Cai, Wenting Liu, Lin Li, Min Shi, Yuehui Sun, Lina Ma, Xiaoyun Zou, Jun |
author_facet | Cai, Wenting Liu, Lin Li, Min Shi, Yuehui Sun, Lina Ma, Xiaoyun Zou, Jun |
author_sort | Cai, Wenting |
collection | PubMed |
description | PURPOSE: To investigate changes in corneal densitometry (CD) and visual quality following small incision lenticule extraction (SMILE) and laser epithelial keratomileusis (LASEK) in patients with mild-to-moderate myopia. METHODS: A retrospective analysis was performed on 24 and 25 patients (46 eyes each) who underwent SMILE and LASEK, respectively, for mild-to-moderate myopia. The visual quality and CD values were recorded. Using the Pentacam Scheimpflug system, CD values were collected in three concentric optical zones at the depths of the anterior, central, and posterior layers. Efficacy, safety, predictability, corneal wavefront aberrations, and QoV scores were measured to evaluate visual quality. A correlation analysis was performed between changes in CD and clinical characteristics. RESULTS: There were no statistical differences in efficacy and safety indices between the two groups. At 3 months postoperatively, a pronounced reduction in several zones was observed in the LASEK group (p < 0.05), whereas no obvious change was observed in the SMILE group. There were obvious changes in the CD values in several zones in the SMILE and LASEK groups (p < 0.05) after 1 year. The magnitude of the CD changes in the anterior and central corneal layers was smaller in the SMILE group than in the LASEK group (all p < 0.05). Lower HOAs, spherical aberration, and horizontal comas of the anterior and whole corneal surfaces were observed in the SMILE group. QoV scores were similar between the two groups. CONCLUSION: CD decreased in the SMILE and LASEK groups after 1 year; there was a smaller reduction in SMILE than in LASEK. SMILE and LASEK did not differ significantly in terms of safety and effectiveness in correcting mild-to-moderate myopia. |
format | Online Article Text |
id | pubmed-9911227 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Hindawi |
record_format | MEDLINE/PubMed |
spelling | pubmed-99112272023-02-10 Comparison of Corneal Densitometry and Visual Quality after Small Incision Lenticule Extraction (SMILE) and Laser Epithelial Keratomileusis (LASEK): One-Year Comparative Study Cai, Wenting Liu, Lin Li, Min Shi, Yuehui Sun, Lina Ma, Xiaoyun Zou, Jun Biomed Res Int Research Article PURPOSE: To investigate changes in corneal densitometry (CD) and visual quality following small incision lenticule extraction (SMILE) and laser epithelial keratomileusis (LASEK) in patients with mild-to-moderate myopia. METHODS: A retrospective analysis was performed on 24 and 25 patients (46 eyes each) who underwent SMILE and LASEK, respectively, for mild-to-moderate myopia. The visual quality and CD values were recorded. Using the Pentacam Scheimpflug system, CD values were collected in three concentric optical zones at the depths of the anterior, central, and posterior layers. Efficacy, safety, predictability, corneal wavefront aberrations, and QoV scores were measured to evaluate visual quality. A correlation analysis was performed between changes in CD and clinical characteristics. RESULTS: There were no statistical differences in efficacy and safety indices between the two groups. At 3 months postoperatively, a pronounced reduction in several zones was observed in the LASEK group (p < 0.05), whereas no obvious change was observed in the SMILE group. There were obvious changes in the CD values in several zones in the SMILE and LASEK groups (p < 0.05) after 1 year. The magnitude of the CD changes in the anterior and central corneal layers was smaller in the SMILE group than in the LASEK group (all p < 0.05). Lower HOAs, spherical aberration, and horizontal comas of the anterior and whole corneal surfaces were observed in the SMILE group. QoV scores were similar between the two groups. CONCLUSION: CD decreased in the SMILE and LASEK groups after 1 year; there was a smaller reduction in SMILE than in LASEK. SMILE and LASEK did not differ significantly in terms of safety and effectiveness in correcting mild-to-moderate myopia. Hindawi 2023-02-02 /pmc/articles/PMC9911227/ /pubmed/36778055 http://dx.doi.org/10.1155/2023/3430742 Text en Copyright © 2023 Wenting Cai et al. https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Cai, Wenting Liu, Lin Li, Min Shi, Yuehui Sun, Lina Ma, Xiaoyun Zou, Jun Comparison of Corneal Densitometry and Visual Quality after Small Incision Lenticule Extraction (SMILE) and Laser Epithelial Keratomileusis (LASEK): One-Year Comparative Study |
title | Comparison of Corneal Densitometry and Visual Quality after Small Incision Lenticule Extraction (SMILE) and Laser Epithelial Keratomileusis (LASEK): One-Year Comparative Study |
title_full | Comparison of Corneal Densitometry and Visual Quality after Small Incision Lenticule Extraction (SMILE) and Laser Epithelial Keratomileusis (LASEK): One-Year Comparative Study |
title_fullStr | Comparison of Corneal Densitometry and Visual Quality after Small Incision Lenticule Extraction (SMILE) and Laser Epithelial Keratomileusis (LASEK): One-Year Comparative Study |
title_full_unstemmed | Comparison of Corneal Densitometry and Visual Quality after Small Incision Lenticule Extraction (SMILE) and Laser Epithelial Keratomileusis (LASEK): One-Year Comparative Study |
title_short | Comparison of Corneal Densitometry and Visual Quality after Small Incision Lenticule Extraction (SMILE) and Laser Epithelial Keratomileusis (LASEK): One-Year Comparative Study |
title_sort | comparison of corneal densitometry and visual quality after small incision lenticule extraction (smile) and laser epithelial keratomileusis (lasek): one-year comparative study |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9911227/ https://www.ncbi.nlm.nih.gov/pubmed/36778055 http://dx.doi.org/10.1155/2023/3430742 |
work_keys_str_mv | AT caiwenting comparisonofcornealdensitometryandvisualqualityaftersmallincisionlenticuleextractionsmileandlaserepithelialkeratomileusislasekoneyearcomparativestudy AT liulin comparisonofcornealdensitometryandvisualqualityaftersmallincisionlenticuleextractionsmileandlaserepithelialkeratomileusislasekoneyearcomparativestudy AT limin comparisonofcornealdensitometryandvisualqualityaftersmallincisionlenticuleextractionsmileandlaserepithelialkeratomileusislasekoneyearcomparativestudy AT shiyuehui comparisonofcornealdensitometryandvisualqualityaftersmallincisionlenticuleextractionsmileandlaserepithelialkeratomileusislasekoneyearcomparativestudy AT sunlina comparisonofcornealdensitometryandvisualqualityaftersmallincisionlenticuleextractionsmileandlaserepithelialkeratomileusislasekoneyearcomparativestudy AT maxiaoyun comparisonofcornealdensitometryandvisualqualityaftersmallincisionlenticuleextractionsmileandlaserepithelialkeratomileusislasekoneyearcomparativestudy AT zoujun comparisonofcornealdensitometryandvisualqualityaftersmallincisionlenticuleextractionsmileandlaserepithelialkeratomileusislasekoneyearcomparativestudy |