Cargando…
Task-Based Image Quality Assessment Comparing Classical and Iterative Cone Beam CT Images on Halcyon(®)
Background: Despite the development of iterative reconstruction (IR) in diagnostic imaging, CBCT are generally reconstructed with filtered back projection (FBP) in radiotherapy. Varian medical systems, recently released with their latest Halcyon(®) V2.0 accelerator, a new IR algorithm for CBCT recon...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9914039/ https://www.ncbi.nlm.nih.gov/pubmed/36766553 http://dx.doi.org/10.3390/diagnostics13030448 |
_version_ | 1784885571441655808 |
---|---|
author | Lassot-Buys, Marion Verstraet, Rodolfe Dabli, Djamel Moliner, Gilles Greffier, Joël |
author_facet | Lassot-Buys, Marion Verstraet, Rodolfe Dabli, Djamel Moliner, Gilles Greffier, Joël |
author_sort | Lassot-Buys, Marion |
collection | PubMed |
description | Background: Despite the development of iterative reconstruction (IR) in diagnostic imaging, CBCT are generally reconstructed with filtered back projection (FBP) in radiotherapy. Varian medical systems, recently released with their latest Halcyon(®) V2.0 accelerator, a new IR algorithm for CBCT reconstruction. Purpose: To assess the image quality of radiotherapy CBCT images reconstructed with FBP and an IR algorithm. Methods: Three CBCT acquisition modes (head, thorax and pelvis large) available on a Halcyon(®) were assessed. Five acquisitions were performed for all modes on an image quality phantom and reconstructed with FBP and IR. Task-based image quality assessment was performed with noise power spectrum (NPS), task-based transfer function (TTF) and detectability index (d’). To illustrate the image quality obtained with both reconstruction types, CBCT acquisitions were made on 6 patients. Results: The noise magnitude and the spatial frequency of the NPS peak was lower with IR than with FBP for all modes. For all low and high-contrast inserts, the values for TTF at 50% were higher with IR than with FBP. For all inserts and all modes, the contrast values were similar with FBP and IR. For all low and high-contrast simulated lesions, d’ values were higher with IR than with FBP for all modes. These results were also found on the 6 patients where the images were less noisy but smoother with IR-CBCT. Conclusions: Using the IR algorithm for CBCT images in radiotherapy improve image quality and thus could increase the accuracy of online registration and limit positioning errors during processing. |
format | Online Article Text |
id | pubmed-9914039 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-99140392023-02-11 Task-Based Image Quality Assessment Comparing Classical and Iterative Cone Beam CT Images on Halcyon(®) Lassot-Buys, Marion Verstraet, Rodolfe Dabli, Djamel Moliner, Gilles Greffier, Joël Diagnostics (Basel) Article Background: Despite the development of iterative reconstruction (IR) in diagnostic imaging, CBCT are generally reconstructed with filtered back projection (FBP) in radiotherapy. Varian medical systems, recently released with their latest Halcyon(®) V2.0 accelerator, a new IR algorithm for CBCT reconstruction. Purpose: To assess the image quality of radiotherapy CBCT images reconstructed with FBP and an IR algorithm. Methods: Three CBCT acquisition modes (head, thorax and pelvis large) available on a Halcyon(®) were assessed. Five acquisitions were performed for all modes on an image quality phantom and reconstructed with FBP and IR. Task-based image quality assessment was performed with noise power spectrum (NPS), task-based transfer function (TTF) and detectability index (d’). To illustrate the image quality obtained with both reconstruction types, CBCT acquisitions were made on 6 patients. Results: The noise magnitude and the spatial frequency of the NPS peak was lower with IR than with FBP for all modes. For all low and high-contrast inserts, the values for TTF at 50% were higher with IR than with FBP. For all inserts and all modes, the contrast values were similar with FBP and IR. For all low and high-contrast simulated lesions, d’ values were higher with IR than with FBP for all modes. These results were also found on the 6 patients where the images were less noisy but smoother with IR-CBCT. Conclusions: Using the IR algorithm for CBCT images in radiotherapy improve image quality and thus could increase the accuracy of online registration and limit positioning errors during processing. MDPI 2023-01-26 /pmc/articles/PMC9914039/ /pubmed/36766553 http://dx.doi.org/10.3390/diagnostics13030448 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Lassot-Buys, Marion Verstraet, Rodolfe Dabli, Djamel Moliner, Gilles Greffier, Joël Task-Based Image Quality Assessment Comparing Classical and Iterative Cone Beam CT Images on Halcyon(®) |
title | Task-Based Image Quality Assessment Comparing Classical and Iterative Cone Beam CT Images on Halcyon(®) |
title_full | Task-Based Image Quality Assessment Comparing Classical and Iterative Cone Beam CT Images on Halcyon(®) |
title_fullStr | Task-Based Image Quality Assessment Comparing Classical and Iterative Cone Beam CT Images on Halcyon(®) |
title_full_unstemmed | Task-Based Image Quality Assessment Comparing Classical and Iterative Cone Beam CT Images on Halcyon(®) |
title_short | Task-Based Image Quality Assessment Comparing Classical and Iterative Cone Beam CT Images on Halcyon(®) |
title_sort | task-based image quality assessment comparing classical and iterative cone beam ct images on halcyon(®) |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9914039/ https://www.ncbi.nlm.nih.gov/pubmed/36766553 http://dx.doi.org/10.3390/diagnostics13030448 |
work_keys_str_mv | AT lassotbuysmarion taskbasedimagequalityassessmentcomparingclassicalanditerativeconebeamctimagesonhalcyon AT verstraetrodolfe taskbasedimagequalityassessmentcomparingclassicalanditerativeconebeamctimagesonhalcyon AT dablidjamel taskbasedimagequalityassessmentcomparingclassicalanditerativeconebeamctimagesonhalcyon AT molinergilles taskbasedimagequalityassessmentcomparingclassicalanditerativeconebeamctimagesonhalcyon AT greffierjoel taskbasedimagequalityassessmentcomparingclassicalanditerativeconebeamctimagesonhalcyon |