Cargando…

Similar Sensitivity of SARS-CoV-2 Detection in Oropharyngeal/Nasopharyngeal and Saliva Samples on the Hologic Panther Platform

Background: Oropharyngeal (OP) and nasopharyngeal (NP) sampling has historically been considered the reference specimen type used for respiratory virus detection. Saliva could be a less invasive alternative for SARS-CoV-2 detection, but limited evidence is available. Methods: The technical and clini...

Descripción completa

Detalles Bibliográficos
Autores principales: Vahidnia, Ali, Souverein, Dennis, Euser, Sjoerd M., Haverkort, Milly, Noordhuis, Elise, van Zijl, Thomas Z. I., Kalpoe, Jayant, Sinnige, Jan C., Herpers, Bjorn L.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9914531/
https://www.ncbi.nlm.nih.gov/pubmed/36766452
http://dx.doi.org/10.3390/diagnostics13030347
_version_ 1784885687433035776
author Vahidnia, Ali
Souverein, Dennis
Euser, Sjoerd M.
Haverkort, Milly
Noordhuis, Elise
van Zijl, Thomas Z. I.
Kalpoe, Jayant
Sinnige, Jan C.
Herpers, Bjorn L.
author_facet Vahidnia, Ali
Souverein, Dennis
Euser, Sjoerd M.
Haverkort, Milly
Noordhuis, Elise
van Zijl, Thomas Z. I.
Kalpoe, Jayant
Sinnige, Jan C.
Herpers, Bjorn L.
author_sort Vahidnia, Ali
collection PubMed
description Background: Oropharyngeal (OP) and nasopharyngeal (NP) sampling has historically been considered the reference specimen type used for respiratory virus detection. Saliva could be a less invasive alternative for SARS-CoV-2 detection, but limited evidence is available. Methods: The technical and clinical performance of saliva was compared to OP/NP on the Hologic Panther platform with two Aptima assays, the End-Point Transcription-Mediated Amplification assay (EP-TMA) and Real-Time Transcription-Mediated Amplification assay (RT-TMA). The samples were collected at the Public Health Service Testing Site XL location in Schiphol Amsterdam Airport. At the site, the Regional Public Health Laboratory Kennemerland (RPHLK) has a fully equipped laboratory facility. Results: A total of 374 samples (187 OP/NP swabs and 187 saliva samples) were collected from 187 unique patients. The Real-Time Transcription-Mediated Amplification assay (RT-TMA) resulted in comparable sensitivities for the detection of SARS-CoV-2 in both the OP/NP swabs (88.3%; 113/128) and saliva samples (87.5%; 112/128). The End-Point Transcription-Mediated Amplification assay (EP-TMA) analyses showed a similar sensitivity (86.7%; 111/128) in the OP/NP swabs but a lower sensitivity in the saliva samples (80.5%; 103/128). Within the discordant analyses, we found no associations in the symptoms, earlier SARS-CoV-2 infections and eating, smoking, drinking and tooth brushing habits within one hour before testing. Conclusions: The Hologic Panther platform Real-Time Transcription-Mediated Amplification assay (RT-TMA) yields a sensitivity for the detection of SARS-CoV-2 in saliva that is comparable to the OP/NP swabs derived from participants presenting themselves at a public health testing facility with minimal or mild symptoms.
format Online
Article
Text
id pubmed-9914531
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-99145312023-02-11 Similar Sensitivity of SARS-CoV-2 Detection in Oropharyngeal/Nasopharyngeal and Saliva Samples on the Hologic Panther Platform Vahidnia, Ali Souverein, Dennis Euser, Sjoerd M. Haverkort, Milly Noordhuis, Elise van Zijl, Thomas Z. I. Kalpoe, Jayant Sinnige, Jan C. Herpers, Bjorn L. Diagnostics (Basel) Article Background: Oropharyngeal (OP) and nasopharyngeal (NP) sampling has historically been considered the reference specimen type used for respiratory virus detection. Saliva could be a less invasive alternative for SARS-CoV-2 detection, but limited evidence is available. Methods: The technical and clinical performance of saliva was compared to OP/NP on the Hologic Panther platform with two Aptima assays, the End-Point Transcription-Mediated Amplification assay (EP-TMA) and Real-Time Transcription-Mediated Amplification assay (RT-TMA). The samples were collected at the Public Health Service Testing Site XL location in Schiphol Amsterdam Airport. At the site, the Regional Public Health Laboratory Kennemerland (RPHLK) has a fully equipped laboratory facility. Results: A total of 374 samples (187 OP/NP swabs and 187 saliva samples) were collected from 187 unique patients. The Real-Time Transcription-Mediated Amplification assay (RT-TMA) resulted in comparable sensitivities for the detection of SARS-CoV-2 in both the OP/NP swabs (88.3%; 113/128) and saliva samples (87.5%; 112/128). The End-Point Transcription-Mediated Amplification assay (EP-TMA) analyses showed a similar sensitivity (86.7%; 111/128) in the OP/NP swabs but a lower sensitivity in the saliva samples (80.5%; 103/128). Within the discordant analyses, we found no associations in the symptoms, earlier SARS-CoV-2 infections and eating, smoking, drinking and tooth brushing habits within one hour before testing. Conclusions: The Hologic Panther platform Real-Time Transcription-Mediated Amplification assay (RT-TMA) yields a sensitivity for the detection of SARS-CoV-2 in saliva that is comparable to the OP/NP swabs derived from participants presenting themselves at a public health testing facility with minimal or mild symptoms. MDPI 2023-01-18 /pmc/articles/PMC9914531/ /pubmed/36766452 http://dx.doi.org/10.3390/diagnostics13030347 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Vahidnia, Ali
Souverein, Dennis
Euser, Sjoerd M.
Haverkort, Milly
Noordhuis, Elise
van Zijl, Thomas Z. I.
Kalpoe, Jayant
Sinnige, Jan C.
Herpers, Bjorn L.
Similar Sensitivity of SARS-CoV-2 Detection in Oropharyngeal/Nasopharyngeal and Saliva Samples on the Hologic Panther Platform
title Similar Sensitivity of SARS-CoV-2 Detection in Oropharyngeal/Nasopharyngeal and Saliva Samples on the Hologic Panther Platform
title_full Similar Sensitivity of SARS-CoV-2 Detection in Oropharyngeal/Nasopharyngeal and Saliva Samples on the Hologic Panther Platform
title_fullStr Similar Sensitivity of SARS-CoV-2 Detection in Oropharyngeal/Nasopharyngeal and Saliva Samples on the Hologic Panther Platform
title_full_unstemmed Similar Sensitivity of SARS-CoV-2 Detection in Oropharyngeal/Nasopharyngeal and Saliva Samples on the Hologic Panther Platform
title_short Similar Sensitivity of SARS-CoV-2 Detection in Oropharyngeal/Nasopharyngeal and Saliva Samples on the Hologic Panther Platform
title_sort similar sensitivity of sars-cov-2 detection in oropharyngeal/nasopharyngeal and saliva samples on the hologic panther platform
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9914531/
https://www.ncbi.nlm.nih.gov/pubmed/36766452
http://dx.doi.org/10.3390/diagnostics13030347
work_keys_str_mv AT vahidniaali similarsensitivityofsarscov2detectioninoropharyngealnasopharyngealandsalivasamplesonthehologicpantherplatform
AT souvereindennis similarsensitivityofsarscov2detectioninoropharyngealnasopharyngealandsalivasamplesonthehologicpantherplatform
AT eusersjoerdm similarsensitivityofsarscov2detectioninoropharyngealnasopharyngealandsalivasamplesonthehologicpantherplatform
AT haverkortmilly similarsensitivityofsarscov2detectioninoropharyngealnasopharyngealandsalivasamplesonthehologicpantherplatform
AT noordhuiselise similarsensitivityofsarscov2detectioninoropharyngealnasopharyngealandsalivasamplesonthehologicpantherplatform
AT vanzijlthomaszi similarsensitivityofsarscov2detectioninoropharyngealnasopharyngealandsalivasamplesonthehologicpantherplatform
AT kalpoejayant similarsensitivityofsarscov2detectioninoropharyngealnasopharyngealandsalivasamplesonthehologicpantherplatform
AT sinnigejanc similarsensitivityofsarscov2detectioninoropharyngealnasopharyngealandsalivasamplesonthehologicpantherplatform
AT herpersbjornl similarsensitivityofsarscov2detectioninoropharyngealnasopharyngealandsalivasamplesonthehologicpantherplatform